Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue

BACKGROUND: Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to e...

Descripción completa

Detalles Bibliográficos
Autores principales: Sowan, Azizeh Khaled, Tarriela, Albert Fajardo, Gomez, Tiffany Michelle, Reed, Charles Calhoun, Rapp, Kami Marie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Gunther Eysenbach 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4797660/
https://www.ncbi.nlm.nih.gov/pubmed/27025940
http://dx.doi.org/10.2196/humanfactors.4196
_version_ 1782421998252589056
author Sowan, Azizeh Khaled
Tarriela, Albert Fajardo
Gomez, Tiffany Michelle
Reed, Charles Calhoun
Rapp, Kami Marie
author_facet Sowan, Azizeh Khaled
Tarriela, Albert Fajardo
Gomez, Tiffany Michelle
Reed, Charles Calhoun
Rapp, Kami Marie
author_sort Sowan, Azizeh Khaled
collection PubMed
description BACKGROUND: Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to establish alarm systems safety as a hospital priority by July 2014. An important initial step toward this requirement is identifying ICU nurses’ perceptions and common clinical practices toward clinical alarms, where little information is available. OBJECTIVE: Our aim was to determine perceptions and practices of transplant/cardiac ICU (TCICU) nurses toward clinical alarms and benchmark the results against the 2011 Healthcare Technology Foundation’s (HTF) Clinical Alarms Committee Survey. METHODS: A quality improvement project was conducted on a 20-bed TCICU with 39 full- and part-time nurses. Nurses were surveyed about their perceptions and attitudes toward and practices on clinical alarms using an adapted HTF clinical alarms survey. Results were compared to the 2011 HTF data. Correlations among variables were examined. RESULTS: All TCICU nurses provided usable responses (N=39, 100%). Almost all nurses (95%-98%) believed that false alarms are frequent, disrupt care, and reduce trust in alarm systems, causing nurses to inappropriately disable them. Unlike the 2011 HTF clinical alarms survey results, a significantly higher percentage of our TCICU nurses believed that existing devices are complex, questioned the ability and adequacy of the new monitoring systems to solve alarm management issues, pointed to the lack of prompt response to alarms, and indicated the lack of clinical policy on alarm management (P<.01). Major themes in the narrative data focused on nurses’ frustration related to the excessive number of alarms and poor usability of the cardiac monitors. A lack of standardized approaches exists in changing patients’ electrodes and individualizing parameters. Around 60% of nurses indicated they received insufficient training on bedside and central cardiac monitors. A correlation also showed the need for training on cardiac monitors, specifically for older nurses (P=.01). CONCLUSIONS: False and non-actionable alarms continue to desensitize TCICU nurses, perhaps resulting in missing fatal alarms. Nurses’ attitudes and practices related to clinical alarms are key elements for designing contextually sensitive quality initiatives to fight alarm fatigue. Alarm management in ICUs is a multidimensional complex process involving usability of monitoring devices, and unit, clinicians, training, and policy-related factors. This indicates the need for a multi-method approach to decrease alarm fatigue and improve alarm systems safety.
format Online
Article
Text
id pubmed-4797660
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Gunther Eysenbach
record_format MEDLINE/PubMed
spelling pubmed-47976602016-03-23 Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue Sowan, Azizeh Khaled Tarriela, Albert Fajardo Gomez, Tiffany Michelle Reed, Charles Calhoun Rapp, Kami Marie JMIR Hum Factors Original Paper BACKGROUND: Intensive care units (ICUs) are complex work environments where false alarms occur more frequently than on non-critical care units. The Joint Commission National Patient Safety Goal .06.01.01 targeted improving the safety of clinical alarm systems and required health care facilities to establish alarm systems safety as a hospital priority by July 2014. An important initial step toward this requirement is identifying ICU nurses’ perceptions and common clinical practices toward clinical alarms, where little information is available. OBJECTIVE: Our aim was to determine perceptions and practices of transplant/cardiac ICU (TCICU) nurses toward clinical alarms and benchmark the results against the 2011 Healthcare Technology Foundation’s (HTF) Clinical Alarms Committee Survey. METHODS: A quality improvement project was conducted on a 20-bed TCICU with 39 full- and part-time nurses. Nurses were surveyed about their perceptions and attitudes toward and practices on clinical alarms using an adapted HTF clinical alarms survey. Results were compared to the 2011 HTF data. Correlations among variables were examined. RESULTS: All TCICU nurses provided usable responses (N=39, 100%). Almost all nurses (95%-98%) believed that false alarms are frequent, disrupt care, and reduce trust in alarm systems, causing nurses to inappropriately disable them. Unlike the 2011 HTF clinical alarms survey results, a significantly higher percentage of our TCICU nurses believed that existing devices are complex, questioned the ability and adequacy of the new monitoring systems to solve alarm management issues, pointed to the lack of prompt response to alarms, and indicated the lack of clinical policy on alarm management (P<.01). Major themes in the narrative data focused on nurses’ frustration related to the excessive number of alarms and poor usability of the cardiac monitors. A lack of standardized approaches exists in changing patients’ electrodes and individualizing parameters. Around 60% of nurses indicated they received insufficient training on bedside and central cardiac monitors. A correlation also showed the need for training on cardiac monitors, specifically for older nurses (P=.01). CONCLUSIONS: False and non-actionable alarms continue to desensitize TCICU nurses, perhaps resulting in missing fatal alarms. Nurses’ attitudes and practices related to clinical alarms are key elements for designing contextually sensitive quality initiatives to fight alarm fatigue. Alarm management in ICUs is a multidimensional complex process involving usability of monitoring devices, and unit, clinicians, training, and policy-related factors. This indicates the need for a multi-method approach to decrease alarm fatigue and improve alarm systems safety. Gunther Eysenbach 2015-03-16 /pmc/articles/PMC4797660/ /pubmed/27025940 http://dx.doi.org/10.2196/humanfactors.4196 Text en ©Azizeh Khaled Sowan, Albert Fajardo Tarriela, Tiffany Michelle Gomez, Charles Calhoun Reed, Kami Marie Rapp. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 16.03.2015. https://creativecommons.org/licenses/by/2.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/ (https://creativecommons.org/licenses/by/2.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Human Factors, is properly cited. The complete bibliographic information, a link to the original publication on http://humanfactors.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
Sowan, Azizeh Khaled
Tarriela, Albert Fajardo
Gomez, Tiffany Michelle
Reed, Charles Calhoun
Rapp, Kami Marie
Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue
title Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue
title_full Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue
title_fullStr Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue
title_full_unstemmed Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue
title_short Nurses' Perceptions and Practices Toward Clinical Alarms in a Transplant Cardiac Intensive Care Unit: Exploring Key Issues Leading to Alarm Fatigue
title_sort nurses' perceptions and practices toward clinical alarms in a transplant cardiac intensive care unit: exploring key issues leading to alarm fatigue
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4797660/
https://www.ncbi.nlm.nih.gov/pubmed/27025940
http://dx.doi.org/10.2196/humanfactors.4196
work_keys_str_mv AT sowanazizehkhaled nursesperceptionsandpracticestowardclinicalalarmsinatransplantcardiacintensivecareunitexploringkeyissuesleadingtoalarmfatigue
AT tarrielaalbertfajardo nursesperceptionsandpracticestowardclinicalalarmsinatransplantcardiacintensivecareunitexploringkeyissuesleadingtoalarmfatigue
AT gomeztiffanymichelle nursesperceptionsandpracticestowardclinicalalarmsinatransplantcardiacintensivecareunitexploringkeyissuesleadingtoalarmfatigue
AT reedcharlescalhoun nursesperceptionsandpracticestowardclinicalalarmsinatransplantcardiacintensivecareunitexploringkeyissuesleadingtoalarmfatigue
AT rappkamimarie nursesperceptionsandpracticestowardclinicalalarmsinatransplantcardiacintensivecareunitexploringkeyissuesleadingtoalarmfatigue