Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project

BACKGROUND: Clinical alarm systems safety is a national concern, specifically in intensive care units (ICUs) where alarm rates are known to be the highest. Interventional projects that examined the effect of changing default alarm settings on overall alarm rate and on clinicians’ attitudes and pract...

Descripción completa

Detalles Bibliográficos
Autores principales: Sowan, Azizeh Khaled, Gomez, Tiffany Michelle, Tarriela, Albert Fajardo, Reed, Charles Calhoun, Paper, Bruce Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Gunther Eysenbach 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4797663/
https://www.ncbi.nlm.nih.gov/pubmed/27036170
http://dx.doi.org/10.2196/humanfactors.5098
_version_ 1782421998975057920
author Sowan, Azizeh Khaled
Gomez, Tiffany Michelle
Tarriela, Albert Fajardo
Reed, Charles Calhoun
Paper, Bruce Michael
author_facet Sowan, Azizeh Khaled
Gomez, Tiffany Michelle
Tarriela, Albert Fajardo
Reed, Charles Calhoun
Paper, Bruce Michael
author_sort Sowan, Azizeh Khaled
collection PubMed
description BACKGROUND: Clinical alarm systems safety is a national concern, specifically in intensive care units (ICUs) where alarm rates are known to be the highest. Interventional projects that examined the effect of changing default alarm settings on overall alarm rate and on clinicians’ attitudes and practices toward clinical alarms and alarm fatigue are scarce. OBJECTIVE: To examine if (1) a change in default alarm settings of the cardiac monitors and (2) in-service nursing education on cardiac monitor use in an ICU would result in reducing alarm rate and in improving nurses’ attitudes and practices toward clinical alarms. METHODS: This quality improvement project took place in a 20-bed transplant/cardiac ICU with a total of 39 nurses. We implemented a unit-wide change of default alarm settings involving 17 parameters of the cardiac monitors. All nurses received an in-service education on monitor use. Alarm data were collected from the audit log of the cardiac monitors 10 weeks before and 10 weeks after the change in monitors’ parameters. Nurses’ attitudes and practices toward clinical alarms were measured using the Healthcare Technology Foundation National Clinical Alarms Survey, pre- and postintervention. RESULTS: Alarm rate was 87.86 alarms/patient day (a total of 64,500 alarms) at the preintervention period compared to 59.18 alarms/patient day (49,319 alarms) postintervention (P=.01). At baseline, Arterial Blood Pressure (ABP), Pair Premature Ventricular Contractions (PVCs), and Peripheral Capillary Oxygen Saturation (SpO2) alarms were the highest. ABP and SpO2 alarms remained among the top three at the postproject period. Out of the 39 ICU nurses, 24 (62%) provided complete pre- and postproject survey questionnaires. Compared to the preintervention survey, no remarkable changes in the postproject period were reported in nurses’ attitudes. Themes in the narrative data were related to poor usability of cardiac monitors and the frequent alarms. The data showed great variation among nurses in terms of changing alarm parameters and frequency of replacing patients' electrodes. Despite the in-service, 50% (12/24) of the nurses specified their need for more training on cardiac monitors in the postproject period. CONCLUSIONS: Changing default alarm settings and standard in-service education on cardiac monitor use are insufficient to improve alarm systems safety. Alarm management in ICUs is very complex, involving alarm management practices by clinicians, availability of unit policies and procedures, unit layout, complexity and usability of monitoring devices, and adequacy of training on system use. The complexity of the newer monitoring systems requires urgent usability testing and multidimensional interventions to improve alarm systems safety and to attain the Joint Commission National Patient Safety Goal on alarm systems safety in critical care units.
format Online
Article
Text
id pubmed-4797663
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Gunther Eysenbach
record_format MEDLINE/PubMed
spelling pubmed-47976632016-03-23 Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project Sowan, Azizeh Khaled Gomez, Tiffany Michelle Tarriela, Albert Fajardo Reed, Charles Calhoun Paper, Bruce Michael JMIR Hum Factors Original Paper BACKGROUND: Clinical alarm systems safety is a national concern, specifically in intensive care units (ICUs) where alarm rates are known to be the highest. Interventional projects that examined the effect of changing default alarm settings on overall alarm rate and on clinicians’ attitudes and practices toward clinical alarms and alarm fatigue are scarce. OBJECTIVE: To examine if (1) a change in default alarm settings of the cardiac monitors and (2) in-service nursing education on cardiac monitor use in an ICU would result in reducing alarm rate and in improving nurses’ attitudes and practices toward clinical alarms. METHODS: This quality improvement project took place in a 20-bed transplant/cardiac ICU with a total of 39 nurses. We implemented a unit-wide change of default alarm settings involving 17 parameters of the cardiac monitors. All nurses received an in-service education on monitor use. Alarm data were collected from the audit log of the cardiac monitors 10 weeks before and 10 weeks after the change in monitors’ parameters. Nurses’ attitudes and practices toward clinical alarms were measured using the Healthcare Technology Foundation National Clinical Alarms Survey, pre- and postintervention. RESULTS: Alarm rate was 87.86 alarms/patient day (a total of 64,500 alarms) at the preintervention period compared to 59.18 alarms/patient day (49,319 alarms) postintervention (P=.01). At baseline, Arterial Blood Pressure (ABP), Pair Premature Ventricular Contractions (PVCs), and Peripheral Capillary Oxygen Saturation (SpO2) alarms were the highest. ABP and SpO2 alarms remained among the top three at the postproject period. Out of the 39 ICU nurses, 24 (62%) provided complete pre- and postproject survey questionnaires. Compared to the preintervention survey, no remarkable changes in the postproject period were reported in nurses’ attitudes. Themes in the narrative data were related to poor usability of cardiac monitors and the frequent alarms. The data showed great variation among nurses in terms of changing alarm parameters and frequency of replacing patients' electrodes. Despite the in-service, 50% (12/24) of the nurses specified their need for more training on cardiac monitors in the postproject period. CONCLUSIONS: Changing default alarm settings and standard in-service education on cardiac monitor use are insufficient to improve alarm systems safety. Alarm management in ICUs is very complex, involving alarm management practices by clinicians, availability of unit policies and procedures, unit layout, complexity and usability of monitoring devices, and adequacy of training on system use. The complexity of the newer monitoring systems requires urgent usability testing and multidimensional interventions to improve alarm systems safety and to attain the Joint Commission National Patient Safety Goal on alarm systems safety in critical care units. Gunther Eysenbach 2016-01-11 /pmc/articles/PMC4797663/ /pubmed/27036170 http://dx.doi.org/10.2196/humanfactors.5098 Text en ©Azizeh Khaled Sowan, Tiffany Michelle Gomez, Albert Fajardo Tarriela, Charles Calhoun Reed, Bruce Michael Paper. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 11.01.2016. https://creativecommons.org/licenses/by/2.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/ (https://creativecommons.org/licenses/by/2.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Human Factors, is properly cited. The complete bibliographic information, a link to the original publication on http://humanfactors.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
Sowan, Azizeh Khaled
Gomez, Tiffany Michelle
Tarriela, Albert Fajardo
Reed, Charles Calhoun
Paper, Bruce Michael
Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project
title Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project
title_full Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project
title_fullStr Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project
title_full_unstemmed Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project
title_short Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project
title_sort changes in default alarm settings and standard in-service are insufficient to improve alarm fatigue in an intensive care unit: a pilot project
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4797663/
https://www.ncbi.nlm.nih.gov/pubmed/27036170
http://dx.doi.org/10.2196/humanfactors.5098
work_keys_str_mv AT sowanazizehkhaled changesindefaultalarmsettingsandstandardinserviceareinsufficienttoimprovealarmfatigueinanintensivecareunitapilotproject
AT gomeztiffanymichelle changesindefaultalarmsettingsandstandardinserviceareinsufficienttoimprovealarmfatigueinanintensivecareunitapilotproject
AT tarrielaalbertfajardo changesindefaultalarmsettingsandstandardinserviceareinsufficienttoimprovealarmfatigueinanintensivecareunitapilotproject
AT reedcharlescalhoun changesindefaultalarmsettingsandstandardinserviceareinsufficienttoimprovealarmfatigueinanintensivecareunitapilotproject
AT paperbrucemichael changesindefaultalarmsettingsandstandardinserviceareinsufficienttoimprovealarmfatigueinanintensivecareunitapilotproject