Diabetic neuropathy increases stimulation threshold during popliteal sciatic nerve block(†)

BACKGROUND: Peripheral nerve stimulation is commonly used for nerve localization in regional anaesthesia, but recommended stimulation currents of 0.3–0.5 mA do not reliably produce motor activity in the absence of intraneural needle placement. As this may be particularly true in patients with diabet...

Descripción completa

Detalles Bibliográficos
Autores principales: Heschl, S., Hallmann, B., Zilke, T., Gemes, G., Schoerghuber, M., Auer-Grumbach, M., Quehenberger, F., Lirk, P., Hogan, Q., Rigaud, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4797685/
https://www.ncbi.nlm.nih.gov/pubmed/26994231
http://dx.doi.org/10.1093/bja/aew027
Descripción
Sumario:BACKGROUND: Peripheral nerve stimulation is commonly used for nerve localization in regional anaesthesia, but recommended stimulation currents of 0.3–0.5 mA do not reliably produce motor activity in the absence of intraneural needle placement. As this may be particularly true in patients with diabetic neuropathy, we examined the stimulation threshold in patients with and without diabetes. METHODS: Preoperative evaluation included a neurological exam and electroneurography. During ultrasound-guided popliteal sciatic nerve block, we measured the current required to produce motor activity for the tibial and common peroneal nerve in diabetic and non-diabetic patients. Proximity to the nerve was evaluated post-hoc using ultrasound imaging. RESULTS: Average stimulation currents did not differ between diabetic (n=55) and non-diabetic patients (n=52). Although the planned number of patients was not reached, the power goal for the mean stimulation current was met. Subjects with diminished pressure perception showed increased thresholds for the common peroneal nerve (median 1.30 vs. 0.57 mA in subjects with normal perception, P=0.042), as did subjects with decreased pain sensation (1.60 vs. 0.50 mA in subjects with normal sensation, P=0.038). Slowed ulnar nerve conduction velocity predicted elevated mean stimulation current (r=−0.35, P=0.002). Finally, 15 diabetic patients required more than 0.5 mA to evoke a motor response, despite intraneural needle placement (n=4), or required currents ≥2 mA despite needle-nerve contact, vs three such patients (1 intraneural, 2 with ≥2 mA) among non-diabetic patients (P=0.003). CONCLUSIONS: These findings suggest that stimulation thresholds of 0.3–0.5 mA may not reliably determine close needle-nerve contact during popliteal sciatic nerve block, particularly in patients with diabetic neuropathy. CLINICAL TRIAL REGISTRATION: NCT01488474