Cargando…

COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES

The aim of this study was to evaluate the accuracy of simple radiography, ultrasound and magnetic resonance imaging (MRI) in diagnosing rotator cuff injuries, comparing their findings with open or arthroscopic surgery findings. Methods: Protocols of the Shoulder and Elbow Surgery Service for patient...

Descripción completa

Detalles Bibliográficos
Autores principales: El-Kouba, Gabriel, Andreas Huber, Thomas, Freitas, José Renato Wilke, Steglich, Valdir, Ayzemberg, Henrique, Santos, Adriano M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799092/
https://www.ncbi.nlm.nih.gov/pubmed/27022589
http://dx.doi.org/10.1016/S2255-4971(15)30430-4
_version_ 1782422270659002368
author El-Kouba, Gabriel
Andreas Huber, Thomas
Freitas, José Renato Wilke
Steglich, Valdir
Ayzemberg, Henrique
Santos, Adriano M.
author_facet El-Kouba, Gabriel
Andreas Huber, Thomas
Freitas, José Renato Wilke
Steglich, Valdir
Ayzemberg, Henrique
Santos, Adriano M.
author_sort El-Kouba, Gabriel
collection PubMed
description The aim of this study was to evaluate the accuracy of simple radiography, ultrasound and magnetic resonance imaging (MRI) in diagnosing rotator cuff injuries, comparing their findings with open or arthroscopic surgery findings. Methods: Protocols of the Shoulder and Elbow Surgery Service for patients undergoing surgical treatment for rotator cuff injuries diagnosed by means of radiography, ultrasound and/or MRI between 2002 and 2007 were evaluated. Based on the data gathered, we analyzed the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of these complementary examinations, compared with the findings during the surgical procedures. Results: This study included 147 patients with a mean age of 46.09 years. All the patients had undergone a radiography examination, 101 had undergone ultrasound examination and 72 had undergone MRI. We found sensitivity of 13.8%, specificity of 2.6% and accuracy of 30% with radiography; sensitivity of 57.6%, specificity of 29.6% and accuracy of 51.4% with ultrasound; and sensitivity of 86.6%, specificity of 22.2% and accuracy of 63.3% with MRI. Conclusion: Radiography was found to be a specific examination when the mirror sign was present. MRI and ultrasound were shown to be reliable methods with high accuracy for diagnosing rotator cuff injuries.
format Online
Article
Text
id pubmed-4799092
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-47990922016-03-28 COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES El-Kouba, Gabriel Andreas Huber, Thomas Freitas, José Renato Wilke Steglich, Valdir Ayzemberg, Henrique Santos, Adriano M. Rev Bras Ortop Artigo Original The aim of this study was to evaluate the accuracy of simple radiography, ultrasound and magnetic resonance imaging (MRI) in diagnosing rotator cuff injuries, comparing their findings with open or arthroscopic surgery findings. Methods: Protocols of the Shoulder and Elbow Surgery Service for patients undergoing surgical treatment for rotator cuff injuries diagnosed by means of radiography, ultrasound and/or MRI between 2002 and 2007 were evaluated. Based on the data gathered, we analyzed the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of these complementary examinations, compared with the findings during the surgical procedures. Results: This study included 147 patients with a mean age of 46.09 years. All the patients had undergone a radiography examination, 101 had undergone ultrasound examination and 72 had undergone MRI. We found sensitivity of 13.8%, specificity of 2.6% and accuracy of 30% with radiography; sensitivity of 57.6%, specificity of 29.6% and accuracy of 51.4% with ultrasound; and sensitivity of 86.6%, specificity of 22.2% and accuracy of 63.3% with MRI. Conclusion: Radiography was found to be a specific examination when the mirror sign was present. MRI and ultrasound were shown to be reliable methods with high accuracy for diagnosing rotator cuff injuries. Elsevier 2015-12-12 /pmc/articles/PMC4799092/ /pubmed/27022589 http://dx.doi.org/10.1016/S2255-4971(15)30430-4 Text en © 2010 Sociedade Brasileira de Ortopedia e Traumatologia http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Artigo Original
El-Kouba, Gabriel
Andreas Huber, Thomas
Freitas, José Renato Wilke
Steglich, Valdir
Ayzemberg, Henrique
Santos, Adriano M.
COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES
title COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES
title_full COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES
title_fullStr COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES
title_full_unstemmed COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES
title_short COMPARISON OF COMPLEMENTARY EXAMS IN THE DIAGNOSIS OF ROTATOR CUFF INJURIES
title_sort comparison of complementary exams in the diagnosis of rotator cuff injuries
topic Artigo Original
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799092/
https://www.ncbi.nlm.nih.gov/pubmed/27022589
http://dx.doi.org/10.1016/S2255-4971(15)30430-4
work_keys_str_mv AT elkoubagabriel comparisonofcomplementaryexamsinthediagnosisofrotatorcuffinjuries
AT andreashuberthomas comparisonofcomplementaryexamsinthediagnosisofrotatorcuffinjuries
AT freitasjoserenatowilke comparisonofcomplementaryexamsinthediagnosisofrotatorcuffinjuries
AT steglichvaldir comparisonofcomplementaryexamsinthediagnosisofrotatorcuffinjuries
AT ayzemberghenrique comparisonofcomplementaryexamsinthediagnosisofrotatorcuffinjuries
AT santosadrianom comparisonofcomplementaryexamsinthediagnosisofrotatorcuffinjuries