Cargando…
A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY
Objective: To describe and clinically and radiographically compare patients who underwent total knee arthroplasty (TKA) with all-polyethylene (ALP) and metal-backed (MTB) tibial implants. Methods: Patients who underwent TKA between January 1988 and December 2004 were grouped according to the type of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799093/ https://www.ncbi.nlm.nih.gov/pubmed/27022556 http://dx.doi.org/10.1016/S2255-4971(15)30372-4 |
_version_ | 1782422270875009024 |
---|---|
author | de Andrade, Marco Antônio Percope dos Santos, Juliano Rodrigues Gonzaga, Luiz Gustavo Alves Silva, Guilherme Moreira Abreu e |
author_facet | de Andrade, Marco Antônio Percope dos Santos, Juliano Rodrigues Gonzaga, Luiz Gustavo Alves Silva, Guilherme Moreira Abreu e |
author_sort | de Andrade, Marco Antônio Percope |
collection | PubMed |
description | Objective: To describe and clinically and radiographically compare patients who underwent total knee arthroplasty (TKA) with all-polyethylene (ALP) and metal-backed (MTB) tibial implants. Methods: Patients who underwent TKA between January 1988 and December 2004 were grouped according to the type of implant received: all-polyethylene or metal-backed. Sixty patients came for evaluations, totaling 82 operated knees. Among these, 22 patients had undergone TKA only with ALP (12 unilateral and 10 bilateral cases), 33 patients only with MTB (26 unilateral and 7 bilateral cases) and five patients underwent TKA with ALP in one knee and MTB in the other. The knees were divided thus: group 1, 37 knees with ALP; and group 2, 45 knees with MTB. Results: There were no differences in clinical or functional evaluations between the groups. The mean radiolucency in the femur was 0.838 mm for the patients in group 1 and 0.356 mm for the patients in group 2 (p = 0.049). For the tibia, in the AP view, there was a mean value of 2.703 mm for group 1 and 0.733 mm for group 2 (p = 0.000). In the lateral view, the mean values for osteolysis was 0.405 mm for group 1 and 0.200 mm for group 2 (p = 0.074). Conclusions: There were no differences between the groups in the functional and clinical evaluations. However, greater radiolucency was observed in the arthroplasties with ALP, both in the femur in the lateral view and in the tibia in the AP view. Level of evidence IV – case series study. |
format | Online Article Text |
id | pubmed-4799093 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-47990932016-03-28 A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY de Andrade, Marco Antônio Percope dos Santos, Juliano Rodrigues Gonzaga, Luiz Gustavo Alves Silva, Guilherme Moreira Abreu e Rev Bras Ortop Original Article Objective: To describe and clinically and radiographically compare patients who underwent total knee arthroplasty (TKA) with all-polyethylene (ALP) and metal-backed (MTB) tibial implants. Methods: Patients who underwent TKA between January 1988 and December 2004 were grouped according to the type of implant received: all-polyethylene or metal-backed. Sixty patients came for evaluations, totaling 82 operated knees. Among these, 22 patients had undergone TKA only with ALP (12 unilateral and 10 bilateral cases), 33 patients only with MTB (26 unilateral and 7 bilateral cases) and five patients underwent TKA with ALP in one knee and MTB in the other. The knees were divided thus: group 1, 37 knees with ALP; and group 2, 45 knees with MTB. Results: There were no differences in clinical or functional evaluations between the groups. The mean radiolucency in the femur was 0.838 mm for the patients in group 1 and 0.356 mm for the patients in group 2 (p = 0.049). For the tibia, in the AP view, there was a mean value of 2.703 mm for group 1 and 0.733 mm for group 2 (p = 0.000). In the lateral view, the mean values for osteolysis was 0.405 mm for group 1 and 0.200 mm for group 2 (p = 0.074). Conclusions: There were no differences between the groups in the functional and clinical evaluations. However, greater radiolucency was observed in the arthroplasties with ALP, both in the femur in the lateral view and in the tibia in the AP view. Level of evidence IV – case series study. Elsevier 2015-11-17 /pmc/articles/PMC4799093/ /pubmed/27022556 http://dx.doi.org/10.1016/S2255-4971(15)30372-4 Text en © 2010 Sociedade Brasileira de Ortopedia e Traumatologia http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article de Andrade, Marco Antônio Percope dos Santos, Juliano Rodrigues Gonzaga, Luiz Gustavo Alves Silva, Guilherme Moreira Abreu e A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY |
title | A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY |
title_full | A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY |
title_fullStr | A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY |
title_full_unstemmed | A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY |
title_short | A FUNCTIONAL AND ROENTGENOGRAPHIC PRELIMINARY COMPARATIVE STUDY USING METAL-BACKED AND ALL-POLYETHYLENE TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY |
title_sort | functional and roentgenographic preliminary comparative study using metal-backed and all-polyethylene tibial components in total knee arthroplasty |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799093/ https://www.ncbi.nlm.nih.gov/pubmed/27022556 http://dx.doi.org/10.1016/S2255-4971(15)30372-4 |
work_keys_str_mv | AT deandrademarcoantoniopercope afunctionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty AT dossantosjulianorodrigues afunctionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty AT gonzagaluizgustavoalves afunctionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty AT silvaguilhermemoreiraabreue afunctionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty AT deandrademarcoantoniopercope functionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty AT dossantosjulianorodrigues functionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty AT gonzagaluizgustavoalves functionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty AT silvaguilhermemoreiraabreue functionalandroentgenographicpreliminarycomparativestudyusingmetalbackedandallpolyethylenetibialcomponentsintotalkneearthroplasty |