Cargando…
STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS
Objectives: To evaluate the functional results from using a fixed-angle locked volar plate for treating fractures of the distal extremity of the radius, using the DASH (disorders of the arm, shoulder and hand) questionnaire and its radiographic correlation with the Lidström classification. Methods:...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799408/ https://www.ncbi.nlm.nih.gov/pubmed/27042637 http://dx.doi.org/10.1016/S2255-4971(15)30102-6 |
_version_ | 1782422341110726656 |
---|---|
author | Machado, Daniel Gonçalves da Cruz Cerqueira, Sergio Auto Rodarte, Rodrigo Ribeiro Pinho de Souza Araújo Netto, Carlos Alberto de Mathias, Marcelo Bezerra |
author_facet | Machado, Daniel Gonçalves da Cruz Cerqueira, Sergio Auto Rodarte, Rodrigo Ribeiro Pinho de Souza Araújo Netto, Carlos Alberto de Mathias, Marcelo Bezerra |
author_sort | Machado, Daniel Gonçalves |
collection | PubMed |
description | Objectives: To evaluate the functional results from using a fixed-angle locked volar plate for treating fractures of the distal extremity of the radius, using the DASH (disorders of the arm, shoulder and hand) questionnaire and its radiographic correlation with the Lidström classification. Methods: Thirty patients with unstable fractures of the distal extremity of the radius were evaluated after they had undergone a surgical procedure consisting of open reduction and internal fixation using a fixed-angle locked volar plate, at the Military Police Central Hospital of Rio de Janeiro between 2008 and 2009. The results were assessed based on range of motion, DASH protocol scores and radiographies with the Lidström classification. Results: The mean age of the patients in the study was 51 years. The mean DASH score was 11.9 points. It was observed that the radiographic findings did not influence the DASH score. It was found that flexion, pronation, supination and radial deviation correlated with the DASH score. Conclusions: The study showed that subjective functional outcomes using the DASH protocol, obtained from using a locked volar plate to treat fractures of the distal extremity of the radius, are influenced by the range of motion, and especially by the flexion, supination, pronation and radial deviation of the wrist after surgery. There is no correlation between the radiological parameters of either the normal or the operated radius, and the subjective functional outcomes assessed using the DASH protocol. |
format | Online Article Text |
id | pubmed-4799408 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-47994082016-04-01 STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS Machado, Daniel Gonçalves da Cruz Cerqueira, Sergio Auto Rodarte, Rodrigo Ribeiro Pinho de Souza Araújo Netto, Carlos Alberto de Mathias, Marcelo Bezerra Rev Bras Ortop Original Article Objectives: To evaluate the functional results from using a fixed-angle locked volar plate for treating fractures of the distal extremity of the radius, using the DASH (disorders of the arm, shoulder and hand) questionnaire and its radiographic correlation with the Lidström classification. Methods: Thirty patients with unstable fractures of the distal extremity of the radius were evaluated after they had undergone a surgical procedure consisting of open reduction and internal fixation using a fixed-angle locked volar plate, at the Military Police Central Hospital of Rio de Janeiro between 2008 and 2009. The results were assessed based on range of motion, DASH protocol scores and radiographies with the Lidström classification. Results: The mean age of the patients in the study was 51 years. The mean DASH score was 11.9 points. It was observed that the radiographic findings did not influence the DASH score. It was found that flexion, pronation, supination and radial deviation correlated with the DASH score. Conclusions: The study showed that subjective functional outcomes using the DASH protocol, obtained from using a locked volar plate to treat fractures of the distal extremity of the radius, are influenced by the range of motion, and especially by the flexion, supination, pronation and radial deviation of the wrist after surgery. There is no correlation between the radiological parameters of either the normal or the operated radius, and the subjective functional outcomes assessed using the DASH protocol. Elsevier 2015-12-06 /pmc/articles/PMC4799408/ /pubmed/27042637 http://dx.doi.org/10.1016/S2255-4971(15)30102-6 Text en © 2012 Sociedade Brasileira de Ortopedia e Traumatologia http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Machado, Daniel Gonçalves da Cruz Cerqueira, Sergio Auto Rodarte, Rodrigo Ribeiro Pinho de Souza Araújo Netto, Carlos Alberto de Mathias, Marcelo Bezerra STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS |
title | STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS |
title_full | STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS |
title_fullStr | STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS |
title_full_unstemmed | STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS |
title_short | STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS |
title_sort | statistical analysis on functional and radiographic results after use of locked volar plate for fractures of the distal radius |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799408/ https://www.ncbi.nlm.nih.gov/pubmed/27042637 http://dx.doi.org/10.1016/S2255-4971(15)30102-6 |
work_keys_str_mv | AT machadodanielgoncalves statisticalanalysisonfunctionalandradiographicresultsafteruseoflockedvolarplateforfracturesofthedistalradius AT dacruzcerqueirasergioauto statisticalanalysisonfunctionalandradiographicresultsafteruseoflockedvolarplateforfracturesofthedistalradius AT rodarterodrigoribeiropinho statisticalanalysisonfunctionalandradiographicresultsafteruseoflockedvolarplateforfracturesofthedistalradius AT desouzaaraujonettocarlosalberto statisticalanalysisonfunctionalandradiographicresultsafteruseoflockedvolarplateforfracturesofthedistalradius AT demathiasmarcelobezerra statisticalanalysisonfunctionalandradiographicresultsafteruseoflockedvolarplateforfracturesofthedistalradius |