Cargando…

Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold

BACKGROUND: Recently, local sustained-release antibiotics systems have been developed because they can increase local foci of concentrated antibiotics without increasing the plasma concentration, and thereby effectively decrease any systemic toxicity and side effects. A vancomycin-loaded bone-like h...

Descripción completa

Detalles Bibliográficos
Autores principales: Cao, Zhi-Dong, Jiang, Dian-Ming, Yan, Ling, Wu, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799547/
https://www.ncbi.nlm.nih.gov/pubmed/26830991
http://dx.doi.org/10.4103/0366-6999.173489
_version_ 1782422368863387648
author Cao, Zhi-Dong
Jiang, Dian-Ming
Yan, Ling
Wu, Jun
author_facet Cao, Zhi-Dong
Jiang, Dian-Ming
Yan, Ling
Wu, Jun
author_sort Cao, Zhi-Dong
collection PubMed
description BACKGROUND: Recently, local sustained-release antibiotics systems have been developed because they can increase local foci of concentrated antibiotics without increasing the plasma concentration, and thereby effectively decrease any systemic toxicity and side effects. A vancomycin-loaded bone-like hydroxyapatite/poly-amino acid (V-BHA/PAA) bony scaffold was successfully fabricated with vancomycin-loaded poly lactic-co-glycolic acid microspheres and BHA/PAA, which was demonstrated to exhibit both porosity and perfect biodegradability. The aim of this study was to systematically evaluate the biosafety of this novel scaffold by conducting toxicity tests in vitro and in vivo. METHODS: According to the ISO rules for medical implant biosafety, for in vitro tests, the scaffold was incubated with L929 fibroblasts or rabbit noncoagulant blood, with simultaneous creation of positive control and negative control groups. The growth condition of L929 cells and hemolytic ratio were respectively evaluated after various incubation periods. For in vivo tests, a chronic osteomyelitis model involving the right proximal tibia of New Zealand white rabbits was established. After bacterial identification, the drug-loaded scaffold, drug-unloaded BHA/PAA, and poly (methyl methacrylate) were implanted, and a blank control group was also set up. Subsequently, the in vivo blood drug concentrations were measured, and the kidney and liver functions were evaluated. RESULTS: In the in vitro tests, the cytotoxicity grades of V-BHA/PAA and BHA/PAA-based on the relative growth rate were all below 1. The hemolysis ratios of V-BHA/PAA and BHA/PAA were 2.27% and 1.42%, respectively, both below 5%. In the in vivo tests, the blood concentration of vancomycin after implantation of V-BHA/PAA was measured at far below its toxic concentration (60 mg/L), and the function and histomorphology of the liver and kidney were all normal. CONCLUSION: According to ISO standards, the V-BHA/PAA scaffold is considered to have sufficient safety for clinical utilization.
format Online
Article
Text
id pubmed-4799547
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-47995472016-04-04 Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold Cao, Zhi-Dong Jiang, Dian-Ming Yan, Ling Wu, Jun Chin Med J (Engl) Original Article BACKGROUND: Recently, local sustained-release antibiotics systems have been developed because they can increase local foci of concentrated antibiotics without increasing the plasma concentration, and thereby effectively decrease any systemic toxicity and side effects. A vancomycin-loaded bone-like hydroxyapatite/poly-amino acid (V-BHA/PAA) bony scaffold was successfully fabricated with vancomycin-loaded poly lactic-co-glycolic acid microspheres and BHA/PAA, which was demonstrated to exhibit both porosity and perfect biodegradability. The aim of this study was to systematically evaluate the biosafety of this novel scaffold by conducting toxicity tests in vitro and in vivo. METHODS: According to the ISO rules for medical implant biosafety, for in vitro tests, the scaffold was incubated with L929 fibroblasts or rabbit noncoagulant blood, with simultaneous creation of positive control and negative control groups. The growth condition of L929 cells and hemolytic ratio were respectively evaluated after various incubation periods. For in vivo tests, a chronic osteomyelitis model involving the right proximal tibia of New Zealand white rabbits was established. After bacterial identification, the drug-loaded scaffold, drug-unloaded BHA/PAA, and poly (methyl methacrylate) were implanted, and a blank control group was also set up. Subsequently, the in vivo blood drug concentrations were measured, and the kidney and liver functions were evaluated. RESULTS: In the in vitro tests, the cytotoxicity grades of V-BHA/PAA and BHA/PAA-based on the relative growth rate were all below 1. The hemolysis ratios of V-BHA/PAA and BHA/PAA were 2.27% and 1.42%, respectively, both below 5%. In the in vivo tests, the blood concentration of vancomycin after implantation of V-BHA/PAA was measured at far below its toxic concentration (60 mg/L), and the function and histomorphology of the liver and kidney were all normal. CONCLUSION: According to ISO standards, the V-BHA/PAA scaffold is considered to have sufficient safety for clinical utilization. Medknow Publications & Media Pvt Ltd 2016-01-20 /pmc/articles/PMC4799547/ /pubmed/26830991 http://dx.doi.org/10.4103/0366-6999.173489 Text en Copyright: © 2016 Chinese Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Cao, Zhi-Dong
Jiang, Dian-Ming
Yan, Ling
Wu, Jun
Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold
title Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold
title_full Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold
title_fullStr Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold
title_full_unstemmed Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold
title_short Biosafety of the Novel Vancomycin-loaded Bone-like Hydroxyapatite/Poly-amino Acid Bony Scaffold
title_sort biosafety of the novel vancomycin-loaded bone-like hydroxyapatite/poly-amino acid bony scaffold
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4799547/
https://www.ncbi.nlm.nih.gov/pubmed/26830991
http://dx.doi.org/10.4103/0366-6999.173489
work_keys_str_mv AT caozhidong biosafetyofthenovelvancomycinloadedbonelikehydroxyapatitepolyaminoacidbonyscaffold
AT jiangdianming biosafetyofthenovelvancomycinloadedbonelikehydroxyapatitepolyaminoacidbonyscaffold
AT yanling biosafetyofthenovelvancomycinloadedbonelikehydroxyapatitepolyaminoacidbonyscaffold
AT wujun biosafetyofthenovelvancomycinloadedbonelikehydroxyapatitepolyaminoacidbonyscaffold