Cargando…

Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus

OBJECTIVES: To compare a less cumbersome random albumin creatinine ratio (RACR) with 24-hour urinary albumin excretion (UAE) for detection of renal damage in patients with type 2 diabetes mellitus (T2DM). METHODS: This retrospective study performed between March 2013 and June 2014 at the Department...

Descripción completa

Detalles Bibliográficos
Autor principal: Hasanato, Rana M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Saudi Medical Journal 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4800890/
https://www.ncbi.nlm.nih.gov/pubmed/26905348
http://dx.doi.org/10.15537/smj.2016.3.13567
_version_ 1782422515915685888
author Hasanato, Rana M.
author_facet Hasanato, Rana M.
author_sort Hasanato, Rana M.
collection PubMed
description OBJECTIVES: To compare a less cumbersome random albumin creatinine ratio (RACR) with 24-hour urinary albumin excretion (UAE) for detection of renal damage in patients with type 2 diabetes mellitus (T2DM). METHODS: This retrospective study performed between March 2013 and June 2014 at the Department of Pathology, King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia included 122 patients (mean age 54±15, 104 females and 18 males) with T2DM. Urine albumin levels of <30 mg/g was considered normal, from 30-300 mg/g considered as micro-albuminuria, and over 300 mg/g considered as macro-albuminuria. RESULTS: Concordance between the 2 assays was observed in 114 (93.4%) samples. The sensitivity of RACR assay was 100%, specificity was 91.3% with a positive predictive value (PPV) of 95%, and a negative predictive value (NPV) of 100% in micro-albuminuria range. For macro-albuminuria, RACR had a sensitivity of 100%, specificity of 94.1% with PPV of 94% and NPV of 100%. Receiver operating characteristic (ROC) curves analysis cut-off values of 40 mg/g-300 mg/g for micro- and >300 mg/g for macro-albuminuria revealed 100% sensitivity, 97.5% specificity, 95% PPV, and 100% NPV for micro-albuminuria, and 100% sensitivity, 94% specificity, 76% PPV, and 100% NPP for macro-albuminuria. The area under the curve for micro-albuminuria was 100% and 98.2% for macro-albuminuria. CONCLUSION: Performance of RACR was comparable to 24 hour UAE assay particularly in excluding renal damage in T2DM.
format Online
Article
Text
id pubmed-4800890
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Saudi Medical Journal
record_format MEDLINE/PubMed
spelling pubmed-48008902016-04-01 Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus Hasanato, Rana M. Saudi Med J Original Article OBJECTIVES: To compare a less cumbersome random albumin creatinine ratio (RACR) with 24-hour urinary albumin excretion (UAE) for detection of renal damage in patients with type 2 diabetes mellitus (T2DM). METHODS: This retrospective study performed between March 2013 and June 2014 at the Department of Pathology, King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia included 122 patients (mean age 54±15, 104 females and 18 males) with T2DM. Urine albumin levels of <30 mg/g was considered normal, from 30-300 mg/g considered as micro-albuminuria, and over 300 mg/g considered as macro-albuminuria. RESULTS: Concordance between the 2 assays was observed in 114 (93.4%) samples. The sensitivity of RACR assay was 100%, specificity was 91.3% with a positive predictive value (PPV) of 95%, and a negative predictive value (NPV) of 100% in micro-albuminuria range. For macro-albuminuria, RACR had a sensitivity of 100%, specificity of 94.1% with PPV of 94% and NPV of 100%. Receiver operating characteristic (ROC) curves analysis cut-off values of 40 mg/g-300 mg/g for micro- and >300 mg/g for macro-albuminuria revealed 100% sensitivity, 97.5% specificity, 95% PPV, and 100% NPV for micro-albuminuria, and 100% sensitivity, 94% specificity, 76% PPV, and 100% NPP for macro-albuminuria. The area under the curve for micro-albuminuria was 100% and 98.2% for macro-albuminuria. CONCLUSION: Performance of RACR was comparable to 24 hour UAE assay particularly in excluding renal damage in T2DM. Saudi Medical Journal 2016-03 /pmc/articles/PMC4800890/ /pubmed/26905348 http://dx.doi.org/10.15537/smj.2016.3.13567 Text en Copyright: © Saudi Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hasanato, Rana M.
Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus
title Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus
title_full Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus
title_fullStr Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus
title_full_unstemmed Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus
title_short Diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus
title_sort diagnostic efficacy of random albumin creatinine ratio for detection of micro and macro-albuminuria in type 2 diabetes mellitus
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4800890/
https://www.ncbi.nlm.nih.gov/pubmed/26905348
http://dx.doi.org/10.15537/smj.2016.3.13567
work_keys_str_mv AT hasanatoranam diagnosticefficacyofrandomalbumincreatinineratiofordetectionofmicroandmacroalbuminuriaintype2diabetesmellitus