Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal

Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the br...

Descripción completa

Detalles Bibliográficos
Autores principales: Mannan, Malik M. Naeem, Kim, Shinjung, Jeong, Myung Yung, Kamran, M. Ahmad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4801617/
https://www.ncbi.nlm.nih.gov/pubmed/26907276
http://dx.doi.org/10.3390/s16020241
_version_ 1782422609957224448
author Mannan, Malik M. Naeem
Kim, Shinjung
Jeong, Myung Yung
Kamran, M. Ahmad
author_facet Mannan, Malik M. Naeem
Kim, Shinjung
Jeong, Myung Yung
Kamran, M. Ahmad
author_sort Mannan, Malik M. Naeem
collection PubMed
description Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data.
format Online
Article
Text
id pubmed-4801617
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-48016172016-03-25 Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal Mannan, Malik M. Naeem Kim, Shinjung Jeong, Myung Yung Kamran, M. Ahmad Sensors (Basel) Article Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data. MDPI 2016-02-19 /pmc/articles/PMC4801617/ /pubmed/26907276 http://dx.doi.org/10.3390/s16020241 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mannan, Malik M. Naeem
Kim, Shinjung
Jeong, Myung Yung
Kamran, M. Ahmad
Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal
title Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal
title_full Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal
title_fullStr Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal
title_full_unstemmed Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal
title_short Hybrid EEG—Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal
title_sort hybrid eeg—eye tracker: automatic identification and removal of eye movement and blink artifacts from electroencephalographic signal
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4801617/
https://www.ncbi.nlm.nih.gov/pubmed/26907276
http://dx.doi.org/10.3390/s16020241
work_keys_str_mv AT mannanmalikmnaeem hybrideegeyetrackerautomaticidentificationandremovalofeyemovementandblinkartifactsfromelectroencephalographicsignal
AT kimshinjung hybrideegeyetrackerautomaticidentificationandremovalofeyemovementandblinkartifactsfromelectroencephalographicsignal
AT jeongmyungyung hybrideegeyetrackerautomaticidentificationandremovalofeyemovementandblinkartifactsfromelectroencephalographicsignal
AT kamranmahmad hybrideegeyetrackerautomaticidentificationandremovalofeyemovementandblinkartifactsfromelectroencephalographicsignal