Cargando…

Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease

BACKGROUND: The “Timed Up and Go” (TUG) is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson’s Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG]), the individual components of the iTUG and the trunk kin...

Descripción completa

Detalles Bibliográficos
Autores principales: van Lummel, Rob C., Walgaard, Stefan, Hobert, Markus A., Maetzler, Walter, van Dieën, Jaap H., Galindo-Garre, Francisca, Terwee, Caroline B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4801645/
https://www.ncbi.nlm.nih.gov/pubmed/26999051
http://dx.doi.org/10.1371/journal.pone.0151881
_version_ 1782422616225611776
author van Lummel, Rob C.
Walgaard, Stefan
Hobert, Markus A.
Maetzler, Walter
van Dieën, Jaap H.
Galindo-Garre, Francisca
Terwee, Caroline B.
author_facet van Lummel, Rob C.
Walgaard, Stefan
Hobert, Markus A.
Maetzler, Walter
van Dieën, Jaap H.
Galindo-Garre, Francisca
Terwee, Caroline B.
author_sort van Lummel, Rob C.
collection PubMed
description BACKGROUND: The “Timed Up and Go” (TUG) is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson’s Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG]), the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information. OBJECTIVE: The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson’s Disease. METHODS: Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands) was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability. RESULTS: Nineteen ICC values (15%) were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49%) were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24%) were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12%) were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2%) were < 0.30 indicating very poor reliability. CONCLUSIONS: In conclusion, in patients with Parkinson’s disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG) was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements demonstrate that several reliable TUG parameters can be identified that provide a basis for a more precise, quantitative use of the TUG test, in clinical practice.
format Online
Article
Text
id pubmed-4801645
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48016452016-03-23 Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease van Lummel, Rob C. Walgaard, Stefan Hobert, Markus A. Maetzler, Walter van Dieën, Jaap H. Galindo-Garre, Francisca Terwee, Caroline B. PLoS One Research Article BACKGROUND: The “Timed Up and Go” (TUG) is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson’s Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG]), the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information. OBJECTIVE: The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson’s Disease. METHODS: Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands) was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability. RESULTS: Nineteen ICC values (15%) were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49%) were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24%) were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12%) were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2%) were < 0.30 indicating very poor reliability. CONCLUSIONS: In conclusion, in patients with Parkinson’s disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG) was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements demonstrate that several reliable TUG parameters can be identified that provide a basis for a more precise, quantitative use of the TUG test, in clinical practice. Public Library of Science 2016-03-21 /pmc/articles/PMC4801645/ /pubmed/26999051 http://dx.doi.org/10.1371/journal.pone.0151881 Text en © 2016 van Lummel et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
van Lummel, Rob C.
Walgaard, Stefan
Hobert, Markus A.
Maetzler, Walter
van Dieën, Jaap H.
Galindo-Garre, Francisca
Terwee, Caroline B.
Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease
title Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease
title_full Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease
title_fullStr Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease
title_full_unstemmed Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease
title_short Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG) Test in Patients with Parkinson’s Disease
title_sort intra-rater, inter-rater and test-retest reliability of an instrumented timed up and go (itug) test in patients with parkinson’s disease
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4801645/
https://www.ncbi.nlm.nih.gov/pubmed/26999051
http://dx.doi.org/10.1371/journal.pone.0151881
work_keys_str_mv AT vanlummelrobc intraraterinterraterandtestretestreliabilityofaninstrumentedtimedupandgoitugtestinpatientswithparkinsonsdisease
AT walgaardstefan intraraterinterraterandtestretestreliabilityofaninstrumentedtimedupandgoitugtestinpatientswithparkinsonsdisease
AT hobertmarkusa intraraterinterraterandtestretestreliabilityofaninstrumentedtimedupandgoitugtestinpatientswithparkinsonsdisease
AT maetzlerwalter intraraterinterraterandtestretestreliabilityofaninstrumentedtimedupandgoitugtestinpatientswithparkinsonsdisease
AT vandieenjaaph intraraterinterraterandtestretestreliabilityofaninstrumentedtimedupandgoitugtestinpatientswithparkinsonsdisease
AT galindogarrefrancisca intraraterinterraterandtestretestreliabilityofaninstrumentedtimedupandgoitugtestinpatientswithparkinsonsdisease
AT terweecarolineb intraraterinterraterandtestretestreliabilityofaninstrumentedtimedupandgoitugtestinpatientswithparkinsonsdisease