Cargando…
Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings
Objective: We aimed at studying the hemodynamic response (HR) to Interictal Epileptic Discharges (IEDs) using patient-specific and prolonged simultaneous ElectroEncephaloGraphy (EEG) and functional Near InfraRed Spectroscopy (fNIRS) recordings. Methods: The epileptic generator was localized using Ma...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4801878/ https://www.ncbi.nlm.nih.gov/pubmed/27047325 http://dx.doi.org/10.3389/fnins.2016.00102 |
_version_ | 1782422632946204672 |
---|---|
author | Pellegrino, Giovanni Machado, Alexis von Ellenrieder, Nicolas Watanabe, Satsuki Hall, Jeffery A. Lina, Jean-Marc Kobayashi, Eliane Grova, Christophe |
author_facet | Pellegrino, Giovanni Machado, Alexis von Ellenrieder, Nicolas Watanabe, Satsuki Hall, Jeffery A. Lina, Jean-Marc Kobayashi, Eliane Grova, Christophe |
author_sort | Pellegrino, Giovanni |
collection | PubMed |
description | Objective: We aimed at studying the hemodynamic response (HR) to Interictal Epileptic Discharges (IEDs) using patient-specific and prolonged simultaneous ElectroEncephaloGraphy (EEG) and functional Near InfraRed Spectroscopy (fNIRS) recordings. Methods: The epileptic generator was localized using Magnetoencephalography source imaging. fNIRS montage was tailored for each patient, using an algorithm to optimize the sensitivity to the epileptic generator. Optodes were glued using collodion to achieve prolonged acquisition with high quality signal. fNIRS data analysis was handled with no a priori constraint on HR time course, averaging fNIRS signals to similar IEDs. Cluster-permutation analysis was performed on 3D reconstructed fNIRS data to identify significant spatio-temporal HR clusters. Standard (GLM with fixed HRF) and cluster-permutation EEG-fMRI analyses were performed for comparison purposes. Results: fNIRS detected HR to IEDs for 8/9 patients. It mainly consisted oxy-hemoglobin increases (seven patients), followed by oxy-hemoglobin decreases (six patients). HR was lateralized in six patients and lasted from 8.5 to 30 s. Standard EEG-fMRI analysis detected an HR in 4/9 patients (4/9 without enough IEDs, 1/9 unreliable result). The cluster-permutation EEG-fMRI analysis restricted to the region investigated by fNIRS showed additional strong and non-canonical BOLD responses starting earlier than the IEDs and lasting up to 30 s. Conclusions: (i) EEG-fNIRS is suitable to detect the HR to IEDs and can outperform EEG-fMRI because of prolonged recordings and greater chance to detect IEDs; (ii) cluster-permutation analysis unveils additional HR features underestimated when imposing a canonical HR function (iii) the HR is often bilateral and lasts up to 30 s. |
format | Online Article Text |
id | pubmed-4801878 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-48018782016-04-04 Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings Pellegrino, Giovanni Machado, Alexis von Ellenrieder, Nicolas Watanabe, Satsuki Hall, Jeffery A. Lina, Jean-Marc Kobayashi, Eliane Grova, Christophe Front Neurosci Neuroscience Objective: We aimed at studying the hemodynamic response (HR) to Interictal Epileptic Discharges (IEDs) using patient-specific and prolonged simultaneous ElectroEncephaloGraphy (EEG) and functional Near InfraRed Spectroscopy (fNIRS) recordings. Methods: The epileptic generator was localized using Magnetoencephalography source imaging. fNIRS montage was tailored for each patient, using an algorithm to optimize the sensitivity to the epileptic generator. Optodes were glued using collodion to achieve prolonged acquisition with high quality signal. fNIRS data analysis was handled with no a priori constraint on HR time course, averaging fNIRS signals to similar IEDs. Cluster-permutation analysis was performed on 3D reconstructed fNIRS data to identify significant spatio-temporal HR clusters. Standard (GLM with fixed HRF) and cluster-permutation EEG-fMRI analyses were performed for comparison purposes. Results: fNIRS detected HR to IEDs for 8/9 patients. It mainly consisted oxy-hemoglobin increases (seven patients), followed by oxy-hemoglobin decreases (six patients). HR was lateralized in six patients and lasted from 8.5 to 30 s. Standard EEG-fMRI analysis detected an HR in 4/9 patients (4/9 without enough IEDs, 1/9 unreliable result). The cluster-permutation EEG-fMRI analysis restricted to the region investigated by fNIRS showed additional strong and non-canonical BOLD responses starting earlier than the IEDs and lasting up to 30 s. Conclusions: (i) EEG-fNIRS is suitable to detect the HR to IEDs and can outperform EEG-fMRI because of prolonged recordings and greater chance to detect IEDs; (ii) cluster-permutation analysis unveils additional HR features underestimated when imposing a canonical HR function (iii) the HR is often bilateral and lasts up to 30 s. Frontiers Media S.A. 2016-03-22 /pmc/articles/PMC4801878/ /pubmed/27047325 http://dx.doi.org/10.3389/fnins.2016.00102 Text en Copyright © 2016 Pellegrino, Machado, von Ellenrieder, Watanabe, Hall, Lina, Kobayashi and Grova. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neuroscience Pellegrino, Giovanni Machado, Alexis von Ellenrieder, Nicolas Watanabe, Satsuki Hall, Jeffery A. Lina, Jean-Marc Kobayashi, Eliane Grova, Christophe Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings |
title | Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings |
title_full | Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings |
title_fullStr | Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings |
title_full_unstemmed | Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings |
title_short | Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings |
title_sort | hemodynamic response to interictal epileptiform discharges addressed by personalized eeg-fnirs recordings |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4801878/ https://www.ncbi.nlm.nih.gov/pubmed/27047325 http://dx.doi.org/10.3389/fnins.2016.00102 |
work_keys_str_mv | AT pellegrinogiovanni hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings AT machadoalexis hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings AT vonellenriedernicolas hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings AT watanabesatsuki hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings AT halljefferya hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings AT linajeanmarc hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings AT kobayashieliane hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings AT grovachristophe hemodynamicresponsetointerictalepileptiformdischargesaddressedbypersonalizedeegfnirsrecordings |