Cargando…
Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial
BACKGROUND: The two most commonly used uterotonic drugs in caesarean section are oxytocin and carbetocin, a synthetic oxytocin analogue. Carbetocin has a longer half-life when compared to oxytocin, resulting in a reduced use of additional uterotonics. Oxytocin is known to cause fewer cardiovascular...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4802918/ https://www.ncbi.nlm.nih.gov/pubmed/27004531 http://dx.doi.org/10.1186/s13063-016-1285-5 |
_version_ | 1782422814336221184 |
---|---|
author | Dell-Kuster, Salome Hoesli, Irene Lapaire, Olav Seeberger, Esther Steiner, Luzius A. Bucher, Heiner C. Girard, Thierry |
author_facet | Dell-Kuster, Salome Hoesli, Irene Lapaire, Olav Seeberger, Esther Steiner, Luzius A. Bucher, Heiner C. Girard, Thierry |
author_sort | Dell-Kuster, Salome |
collection | PubMed |
description | BACKGROUND: The two most commonly used uterotonic drugs in caesarean section are oxytocin and carbetocin, a synthetic oxytocin analogue. Carbetocin has a longer half-life when compared to oxytocin, resulting in a reduced use of additional uterotonics. Oxytocin is known to cause fewer cardiovascular side effects when administered as a short-infusion compared to as an intravenous bolus. Based on these findings, we aim at comparing carbetocin 100 mcg given as a slow intravenous bolus with carbetocin 100 mcg applied as a short-infusion in 100 ml 0.9 % sodium chloride in women undergoing a planned or unplanned caesarean delivery. We hypothesise uterine contraction not to be inferior to a bolus application (primary efficacy endpoint) and greater haemodynamic stability to be achieved after a short-infusion than after a bolus administration, as measured by heart rate and mean arterial blood pressure (primary safety endpoint). METHODS/DESIGN: This is a prospective, double-blind, randomised controlled, investigator-initiated, non-inferiority trial taking place at the University Hospital Basel, Switzerland. Uterine tone is quantified by manual palpation by the obstetrician using a linear analogue scale from 0 to 100 at 2, 3, 5 and 10 minutes after cord clamping. We will evaluate whether the lower limit of the confidence interval for the difference of the maximal uterine tone within the first 5 minutes after cord clamping between both groups does not include the pre-specified non-inferiority limit of −10. Both haemodynamic secondary endpoints will be analysed using a linear regression model, adjusting for the baseline value and the dosage of vasoactive drug given between cord clamping and 1 minute thereafter, in order to investigate superiority of a short-infusion as compared to a bolus application. We will follow the extension of CONSORT guidelines for reporting the results of non-inferiority trials. DISCUSSION: Haemodynamic stability and adequate uterine tone are important outcomes in caesarean sections. The results of this trial may be used to optimise these factors and thereby increase patient safety due to a reduction in cardiovascular side effects. TRIAL REGISTRATION: Clinicaltrials.gov NCT02221531 on 19 August 2014 and www.kofam.ch SNCTP000001197 on 15 November 2014. |
format | Online Article Text |
id | pubmed-4802918 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-48029182016-03-23 Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial Dell-Kuster, Salome Hoesli, Irene Lapaire, Olav Seeberger, Esther Steiner, Luzius A. Bucher, Heiner C. Girard, Thierry Trials Study Protocol BACKGROUND: The two most commonly used uterotonic drugs in caesarean section are oxytocin and carbetocin, a synthetic oxytocin analogue. Carbetocin has a longer half-life when compared to oxytocin, resulting in a reduced use of additional uterotonics. Oxytocin is known to cause fewer cardiovascular side effects when administered as a short-infusion compared to as an intravenous bolus. Based on these findings, we aim at comparing carbetocin 100 mcg given as a slow intravenous bolus with carbetocin 100 mcg applied as a short-infusion in 100 ml 0.9 % sodium chloride in women undergoing a planned or unplanned caesarean delivery. We hypothesise uterine contraction not to be inferior to a bolus application (primary efficacy endpoint) and greater haemodynamic stability to be achieved after a short-infusion than after a bolus administration, as measured by heart rate and mean arterial blood pressure (primary safety endpoint). METHODS/DESIGN: This is a prospective, double-blind, randomised controlled, investigator-initiated, non-inferiority trial taking place at the University Hospital Basel, Switzerland. Uterine tone is quantified by manual palpation by the obstetrician using a linear analogue scale from 0 to 100 at 2, 3, 5 and 10 minutes after cord clamping. We will evaluate whether the lower limit of the confidence interval for the difference of the maximal uterine tone within the first 5 minutes after cord clamping between both groups does not include the pre-specified non-inferiority limit of −10. Both haemodynamic secondary endpoints will be analysed using a linear regression model, adjusting for the baseline value and the dosage of vasoactive drug given between cord clamping and 1 minute thereafter, in order to investigate superiority of a short-infusion as compared to a bolus application. We will follow the extension of CONSORT guidelines for reporting the results of non-inferiority trials. DISCUSSION: Haemodynamic stability and adequate uterine tone are important outcomes in caesarean sections. The results of this trial may be used to optimise these factors and thereby increase patient safety due to a reduction in cardiovascular side effects. TRIAL REGISTRATION: Clinicaltrials.gov NCT02221531 on 19 August 2014 and www.kofam.ch SNCTP000001197 on 15 November 2014. BioMed Central 2016-03-22 /pmc/articles/PMC4802918/ /pubmed/27004531 http://dx.doi.org/10.1186/s13063-016-1285-5 Text en © Dell-Kuster et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Study Protocol Dell-Kuster, Salome Hoesli, Irene Lapaire, Olav Seeberger, Esther Steiner, Luzius A. Bucher, Heiner C. Girard, Thierry Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial |
title | Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial |
title_full | Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial |
title_fullStr | Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial |
title_full_unstemmed | Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial |
title_short | Efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial |
title_sort | efficacy and safety of carbetocin applied as an intravenous bolus compared to as a short-infusion for caesarean section: study protocol for a randomised controlled trial |
topic | Study Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4802918/ https://www.ncbi.nlm.nih.gov/pubmed/27004531 http://dx.doi.org/10.1186/s13063-016-1285-5 |
work_keys_str_mv | AT dellkustersalome efficacyandsafetyofcarbetocinappliedasanintravenousboluscomparedtoasashortinfusionforcaesareansectionstudyprotocolforarandomisedcontrolledtrial AT hoesliirene efficacyandsafetyofcarbetocinappliedasanintravenousboluscomparedtoasashortinfusionforcaesareansectionstudyprotocolforarandomisedcontrolledtrial AT lapaireolav efficacyandsafetyofcarbetocinappliedasanintravenousboluscomparedtoasashortinfusionforcaesareansectionstudyprotocolforarandomisedcontrolledtrial AT seebergeresther efficacyandsafetyofcarbetocinappliedasanintravenousboluscomparedtoasashortinfusionforcaesareansectionstudyprotocolforarandomisedcontrolledtrial AT steinerluziusa efficacyandsafetyofcarbetocinappliedasanintravenousboluscomparedtoasashortinfusionforcaesareansectionstudyprotocolforarandomisedcontrolledtrial AT bucherheinerc efficacyandsafetyofcarbetocinappliedasanintravenousboluscomparedtoasashortinfusionforcaesareansectionstudyprotocolforarandomisedcontrolledtrial AT girardthierry efficacyandsafetyofcarbetocinappliedasanintravenousboluscomparedtoasashortinfusionforcaesareansectionstudyprotocolforarandomisedcontrolledtrial |