Cargando…

Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging

BACKGROUND: Three tesla (3T) coronary magnetic resonance angiography (MRA) may be optimized using gadolinium-based contrast agents (GBCA) such as gadofosveset trisodium. The goal of this study was to evaluate if there is a qualitative or quantitative improvement in the coronary arteries with variati...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahlman, Mark A., Raman, Fabio S., Pang, Jianing, Zemrak, Filip, Sandfort, Veit, Penzak, Scott R., Fan, Zhaoyang, Liu, Songtao, Li, Debiao, Bluemke, David A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4804531/
https://www.ncbi.nlm.nih.gov/pubmed/27004532
http://dx.doi.org/10.1186/s12872-015-0152-8
_version_ 1782423037860118528
author Ahlman, Mark A.
Raman, Fabio S.
Pang, Jianing
Zemrak, Filip
Sandfort, Veit
Penzak, Scott R.
Fan, Zhaoyang
Liu, Songtao
Li, Debiao
Bluemke, David A.
author_facet Ahlman, Mark A.
Raman, Fabio S.
Pang, Jianing
Zemrak, Filip
Sandfort, Veit
Penzak, Scott R.
Fan, Zhaoyang
Liu, Songtao
Li, Debiao
Bluemke, David A.
author_sort Ahlman, Mark A.
collection PubMed
description BACKGROUND: Three tesla (3T) coronary magnetic resonance angiography (MRA) may be optimized using gadolinium-based contrast agents (GBCA) such as gadofosveset trisodium. The goal of this study was to evaluate if there is a qualitative or quantitative improvement in the coronary arteries with variation in contrast dose. METHODS: Twenty-eight healthy volunteers were prospectively recruited for coronary MRA at 3T using a steady state injection technique for 3D radial whole-heart image acquisition with retrospective respiratory self-gating (ClinicalTrials.gov identifier: NCT01853592). Nineteen volunteers completed both single- and double-dose imaging instances (0.03 and 0.06 mmol/kg, respectively). Intra-individual comparison of image quality was assessed by measurement of apparent signal/contrast-to-noise ratio (aSNR/aCNR) and subjective evaluation of image quality by 2 independent reviewers. RESULTS: The average duration of coronary MRA acquisition was 7.2 ± 1.2 min. There was significantly higher (60 %, p < 0.001) aSNR of the aorta and right/left ventricle for the double dose compared to single dose injection scheme and aSNR of the coronary arteries increased by 70 % (p < 0.001) for the double dose injection. aCNR increased by +55 % and +60 % in the ventricles and coronary arteries, respectively (p < 0.001). Overall segmental artery visualization for single dose was possible 47 % of the time, which improved to 60 % with double dose (p = 0.019), predominantly driven by improvements in more distal segment visualization (+40 % improvement in mid arterial segments, p = 0.013). CONCLUSIONS: Gadofosveset trisodium dose of 0.06 mmol/kg significantly quantitatively and qualitatively improves the coronary artery image quality compared to 0.03 mmol/kg at 3T for moderate duration (6–8 min) steady state contrast enhanced coronary MRA.
format Online
Article
Text
id pubmed-4804531
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48045312016-03-23 Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging Ahlman, Mark A. Raman, Fabio S. Pang, Jianing Zemrak, Filip Sandfort, Veit Penzak, Scott R. Fan, Zhaoyang Liu, Songtao Li, Debiao Bluemke, David A. BMC Cardiovasc Disord Research Article BACKGROUND: Three tesla (3T) coronary magnetic resonance angiography (MRA) may be optimized using gadolinium-based contrast agents (GBCA) such as gadofosveset trisodium. The goal of this study was to evaluate if there is a qualitative or quantitative improvement in the coronary arteries with variation in contrast dose. METHODS: Twenty-eight healthy volunteers were prospectively recruited for coronary MRA at 3T using a steady state injection technique for 3D radial whole-heart image acquisition with retrospective respiratory self-gating (ClinicalTrials.gov identifier: NCT01853592). Nineteen volunteers completed both single- and double-dose imaging instances (0.03 and 0.06 mmol/kg, respectively). Intra-individual comparison of image quality was assessed by measurement of apparent signal/contrast-to-noise ratio (aSNR/aCNR) and subjective evaluation of image quality by 2 independent reviewers. RESULTS: The average duration of coronary MRA acquisition was 7.2 ± 1.2 min. There was significantly higher (60 %, p < 0.001) aSNR of the aorta and right/left ventricle for the double dose compared to single dose injection scheme and aSNR of the coronary arteries increased by 70 % (p < 0.001) for the double dose injection. aCNR increased by +55 % and +60 % in the ventricles and coronary arteries, respectively (p < 0.001). Overall segmental artery visualization for single dose was possible 47 % of the time, which improved to 60 % with double dose (p = 0.019), predominantly driven by improvements in more distal segment visualization (+40 % improvement in mid arterial segments, p = 0.013). CONCLUSIONS: Gadofosveset trisodium dose of 0.06 mmol/kg significantly quantitatively and qualitatively improves the coronary artery image quality compared to 0.03 mmol/kg at 3T for moderate duration (6–8 min) steady state contrast enhanced coronary MRA. BioMed Central 2016-03-22 /pmc/articles/PMC4804531/ /pubmed/27004532 http://dx.doi.org/10.1186/s12872-015-0152-8 Text en © Ahlman et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Ahlman, Mark A.
Raman, Fabio S.
Pang, Jianing
Zemrak, Filip
Sandfort, Veit
Penzak, Scott R.
Fan, Zhaoyang
Liu, Songtao
Li, Debiao
Bluemke, David A.
Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging
title Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging
title_full Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging
title_fullStr Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging
title_full_unstemmed Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging
title_short Part 2 – Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging
title_sort part 2 – coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4804531/
https://www.ncbi.nlm.nih.gov/pubmed/27004532
http://dx.doi.org/10.1186/s12872-015-0152-8
work_keys_str_mv AT ahlmanmarka part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT ramanfabios part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT pangjianing part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT zemrakfilip part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT sandfortveit part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT penzakscottr part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT fanzhaoyang part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT liusongtao part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT lidebiao part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging
AT bluemkedavida part2coronaryangiographywithgadofosvesettrisodiumaprospectiveintrasubjectcomparisonfordoseoptimizationfor100efficiencyimaging