Cargando…
Improving the Rate of Sufficient Sweat Collected in Infants Referred for Sweat Testing in Michigan
Objective. Sweat collected for testing should have quantity not sufficient (QNS) rate of ≤10% in babies ≤3 months of age. Michigan (MI) cystic fibrosis (CF) centers’ QNS rates were 12% to 25% in 2009. This project was initiated to reduce sweat QNS rates in MI. Methods/Steps. (a) Each center’s sweat...
Autores principales: | Abdulhamid, Ibrahim, Kleyn, Mary, Langbo, Carrie, Gregoire-Bottex, Myrtha, Schuen, John, Shanmugasundaram, Krithika, Nasr, Samya Z |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4804676/ https://www.ncbi.nlm.nih.gov/pubmed/27335913 http://dx.doi.org/10.1177/2333794X14553625 |
Ejemplares similares
-
Five cases of missed cystic fibrosis heterozygous mutations identified after a positive newborn screen on a sibling
por: Qussous, Khaleel, et al.
Publicado: (2022) -
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
por: Baker, Lindsay B.
Publicado: (2019) -
Implications of the Onset of Sweating on the Sweat Lactate Threshold
por: Maeda, Yuta, et al.
Publicado: (2023) -
The effect of sweat sample storage condition on sweat content
por: Klous, Lisa, et al.
Publicado: (2021) -
Skin-interfaced systems for sweat collection and analytics
por: Choi, Jungil, et al.
Publicado: (2018)