Cargando…

New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities

The pneumotachometer is currently the most accepted device to measure tidal breathing, however, it requires the use of a mouthpiece and thus alteration of spontaneous ventilation is implied. Respiratory inductive plethysmography (RIP), which includes two belts, one thoracic and one abdominal, is abl...

Descripción completa

Detalles Bibliográficos
Autores principales: Retory, Yann, Niedzialkowski, Pauline, de Picciotto, Carole, Bonay, Marcel, Petitjean, Michel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4805261/
https://www.ncbi.nlm.nih.gov/pubmed/27008313
http://dx.doi.org/10.1371/journal.pone.0151983
_version_ 1782423122772754432
author Retory, Yann
Niedzialkowski, Pauline
de Picciotto, Carole
Bonay, Marcel
Petitjean, Michel
author_facet Retory, Yann
Niedzialkowski, Pauline
de Picciotto, Carole
Bonay, Marcel
Petitjean, Michel
author_sort Retory, Yann
collection PubMed
description The pneumotachometer is currently the most accepted device to measure tidal breathing, however, it requires the use of a mouthpiece and thus alteration of spontaneous ventilation is implied. Respiratory inductive plethysmography (RIP), which includes two belts, one thoracic and one abdominal, is able to determine spontaneous tidal breathing without the use of a facemask or mouthpiece, however, there are a number of as yet unresolved issues. In this study we aimed to describe and validate a new RIP method, relying on a combination of thoracic RIP and nasal pressure signals taking into account that exercise-induced body movements can easily contaminate RIP thoracic signals by generating tissue motion artifacts. A custom-made time domain algorithm that relies on the elimination of low amplitude artifacts was applied to the raw thoracic RIP signal. Determining this tidal ventilation allowed comparisons between the RIP signal and simultaneously-recorded airflow signals from a calibrated pneumotachometer (PT). We assessed 206 comparisons from 30 volunteers who were asked to breathe spontaneously at rest and during walking on the spot. Comparisons between RIP signals processed by our algorithm and PT showed highly significant correlations for tidal volume (Vt), inspiratory (Ti) and expiratory times (Te). Moreover, bias calculated using the Bland and Altman method were reasonably low for Vt and Ti (0.04 L and 0.02 s, respectively), and acceptable for Te (<0.1 s) and the intercept from regression relationships (0.01 L, 0.06 s, 0.17 s respectively). The Ti/Ttot and Vt/Ti ratios obtained with the two methods were also statistically correlated. We conclude that our methodology (filtering by our algorithm and calibrating with our calibration procedure) for thoracic RIP renders this technique sufficiently accurate to evaluate tidal ventilation variation at rest and during mild to moderate physical activity.
format Online
Article
Text
id pubmed-4805261
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48052612016-03-25 New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities Retory, Yann Niedzialkowski, Pauline de Picciotto, Carole Bonay, Marcel Petitjean, Michel PLoS One Research Article The pneumotachometer is currently the most accepted device to measure tidal breathing, however, it requires the use of a mouthpiece and thus alteration of spontaneous ventilation is implied. Respiratory inductive plethysmography (RIP), which includes two belts, one thoracic and one abdominal, is able to determine spontaneous tidal breathing without the use of a facemask or mouthpiece, however, there are a number of as yet unresolved issues. In this study we aimed to describe and validate a new RIP method, relying on a combination of thoracic RIP and nasal pressure signals taking into account that exercise-induced body movements can easily contaminate RIP thoracic signals by generating tissue motion artifacts. A custom-made time domain algorithm that relies on the elimination of low amplitude artifacts was applied to the raw thoracic RIP signal. Determining this tidal ventilation allowed comparisons between the RIP signal and simultaneously-recorded airflow signals from a calibrated pneumotachometer (PT). We assessed 206 comparisons from 30 volunteers who were asked to breathe spontaneously at rest and during walking on the spot. Comparisons between RIP signals processed by our algorithm and PT showed highly significant correlations for tidal volume (Vt), inspiratory (Ti) and expiratory times (Te). Moreover, bias calculated using the Bland and Altman method were reasonably low for Vt and Ti (0.04 L and 0.02 s, respectively), and acceptable for Te (<0.1 s) and the intercept from regression relationships (0.01 L, 0.06 s, 0.17 s respectively). The Ti/Ttot and Vt/Ti ratios obtained with the two methods were also statistically correlated. We conclude that our methodology (filtering by our algorithm and calibrating with our calibration procedure) for thoracic RIP renders this technique sufficiently accurate to evaluate tidal ventilation variation at rest and during mild to moderate physical activity. Public Library of Science 2016-03-23 /pmc/articles/PMC4805261/ /pubmed/27008313 http://dx.doi.org/10.1371/journal.pone.0151983 Text en © 2016 Retory et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Retory, Yann
Niedzialkowski, Pauline
de Picciotto, Carole
Bonay, Marcel
Petitjean, Michel
New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities
title New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities
title_full New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities
title_fullStr New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities
title_full_unstemmed New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities
title_short New Respiratory Inductive Plethysmography (RIP) Method for Evaluating Ventilatory Adaptation during Mild Physical Activities
title_sort new respiratory inductive plethysmography (rip) method for evaluating ventilatory adaptation during mild physical activities
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4805261/
https://www.ncbi.nlm.nih.gov/pubmed/27008313
http://dx.doi.org/10.1371/journal.pone.0151983
work_keys_str_mv AT retoryyann newrespiratoryinductiveplethysmographyripmethodforevaluatingventilatoryadaptationduringmildphysicalactivities
AT niedzialkowskipauline newrespiratoryinductiveplethysmographyripmethodforevaluatingventilatoryadaptationduringmildphysicalactivities
AT depicciottocarole newrespiratoryinductiveplethysmographyripmethodforevaluatingventilatoryadaptationduringmildphysicalactivities
AT bonaymarcel newrespiratoryinductiveplethysmographyripmethodforevaluatingventilatoryadaptationduringmildphysicalactivities
AT petitjeanmichel newrespiratoryinductiveplethysmographyripmethodforevaluatingventilatoryadaptationduringmildphysicalactivities