Cargando…
Intraoperative Electroretinograms before and after Core Vitrectomy
PURPOSE: To evaluate retinal function by intraoperative electroretinograms (ERGs) before and after core vitrectomy. DESIGN: Retrospective consecutive case series. METHOD: Full-field photopic ERGs were recorded prior to the beginning and just after core vitrectomy using a sterilized contact lens elec...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4806841/ https://www.ncbi.nlm.nih.gov/pubmed/27010332 http://dx.doi.org/10.1371/journal.pone.0152052 |
_version_ | 1782423296163184640 |
---|---|
author | Yagura, Kazuma Shinoda, Kei Matsumoto, Soiti Terauchi, Gaku Watanabe, Emiko Matsumoto, Harue Akiyama, Goichi Mizota, Atsushi Miyake, Yozo |
author_facet | Yagura, Kazuma Shinoda, Kei Matsumoto, Soiti Terauchi, Gaku Watanabe, Emiko Matsumoto, Harue Akiyama, Goichi Mizota, Atsushi Miyake, Yozo |
author_sort | Yagura, Kazuma |
collection | PubMed |
description | PURPOSE: To evaluate retinal function by intraoperative electroretinograms (ERGs) before and after core vitrectomy. DESIGN: Retrospective consecutive case series. METHOD: Full-field photopic ERGs were recorded prior to the beginning and just after core vitrectomy using a sterilized contact lens electrode in 20 eyes that underwent non-complicated vitreous surgery. A light-emitted diode was embedded into the contact lens, and a stimulus of 150 ms on and 350 ms off at 2 Hz was delivered. The amplitudes and latencies of the a-, b-, and d-waves, photopic negative response (PhNR), and oscillatory potentials (OPs) were analyzed. The intraocular temperature at the mid-vitreous was measured at the beginning and just after the surgery with a thermoprobe. RESULTS: The intraocular temperature was 33.2 ± 1.3°C before and 29.4 ± 1.7°C after the vitrectomy. The amplitudes of the PhNR and OPs were significantly smaller after surgery, and the latencies of all components were prolonged after the surgery. These changes were not significantly correlated with the changes of the temperature. CONCLUSION: Retinal function is reduced just after core vitrectomy in conjunction with significant temperature reduction. The differences in the degree of alterations of each ERG component suggests different sensitivity of each type of retinal neuron. |
format | Online Article Text |
id | pubmed-4806841 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-48068412016-03-25 Intraoperative Electroretinograms before and after Core Vitrectomy Yagura, Kazuma Shinoda, Kei Matsumoto, Soiti Terauchi, Gaku Watanabe, Emiko Matsumoto, Harue Akiyama, Goichi Mizota, Atsushi Miyake, Yozo PLoS One Research Article PURPOSE: To evaluate retinal function by intraoperative electroretinograms (ERGs) before and after core vitrectomy. DESIGN: Retrospective consecutive case series. METHOD: Full-field photopic ERGs were recorded prior to the beginning and just after core vitrectomy using a sterilized contact lens electrode in 20 eyes that underwent non-complicated vitreous surgery. A light-emitted diode was embedded into the contact lens, and a stimulus of 150 ms on and 350 ms off at 2 Hz was delivered. The amplitudes and latencies of the a-, b-, and d-waves, photopic negative response (PhNR), and oscillatory potentials (OPs) were analyzed. The intraocular temperature at the mid-vitreous was measured at the beginning and just after the surgery with a thermoprobe. RESULTS: The intraocular temperature was 33.2 ± 1.3°C before and 29.4 ± 1.7°C after the vitrectomy. The amplitudes of the PhNR and OPs were significantly smaller after surgery, and the latencies of all components were prolonged after the surgery. These changes were not significantly correlated with the changes of the temperature. CONCLUSION: Retinal function is reduced just after core vitrectomy in conjunction with significant temperature reduction. The differences in the degree of alterations of each ERG component suggests different sensitivity of each type of retinal neuron. Public Library of Science 2016-03-24 /pmc/articles/PMC4806841/ /pubmed/27010332 http://dx.doi.org/10.1371/journal.pone.0152052 Text en © 2016 Yagura et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Yagura, Kazuma Shinoda, Kei Matsumoto, Soiti Terauchi, Gaku Watanabe, Emiko Matsumoto, Harue Akiyama, Goichi Mizota, Atsushi Miyake, Yozo Intraoperative Electroretinograms before and after Core Vitrectomy |
title | Intraoperative Electroretinograms before and after Core Vitrectomy |
title_full | Intraoperative Electroretinograms before and after Core Vitrectomy |
title_fullStr | Intraoperative Electroretinograms before and after Core Vitrectomy |
title_full_unstemmed | Intraoperative Electroretinograms before and after Core Vitrectomy |
title_short | Intraoperative Electroretinograms before and after Core Vitrectomy |
title_sort | intraoperative electroretinograms before and after core vitrectomy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4806841/ https://www.ncbi.nlm.nih.gov/pubmed/27010332 http://dx.doi.org/10.1371/journal.pone.0152052 |
work_keys_str_mv | AT yagurakazuma intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT shinodakei intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT matsumotosoiti intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT terauchigaku intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT watanabeemiko intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT matsumotoharue intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT akiyamagoichi intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT mizotaatsushi intraoperativeelectroretinogramsbeforeandaftercorevitrectomy AT miyakeyozo intraoperativeelectroretinogramsbeforeandaftercorevitrectomy |