Cargando…

Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies

INTRODUCTION: Patients with acute respiratory distress syndrome (ARDS) typically show a high degree of ventilation inhomogeneity, which is associated with morbidity and unfavorable outcomes. Electrical impedance tomography (EIT) is able to detect ventilation inhomogeneity, but it is unclear which me...

Descripción completa

Detalles Bibliográficos
Autores principales: Becher, Tobias, Vogt, Barbara, Kott, Matthias, Schädler, Dirk, Weiler, Norbert, Frerichs, Inéz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4806869/
https://www.ncbi.nlm.nih.gov/pubmed/27010320
http://dx.doi.org/10.1371/journal.pone.0152267
_version_ 1782423299364487168
author Becher, Tobias
Vogt, Barbara
Kott, Matthias
Schädler, Dirk
Weiler, Norbert
Frerichs, Inéz
author_facet Becher, Tobias
Vogt, Barbara
Kott, Matthias
Schädler, Dirk
Weiler, Norbert
Frerichs, Inéz
author_sort Becher, Tobias
collection PubMed
description INTRODUCTION: Patients with acute respiratory distress syndrome (ARDS) typically show a high degree of ventilation inhomogeneity, which is associated with morbidity and unfavorable outcomes. Electrical impedance tomography (EIT) is able to detect ventilation inhomogeneity, but it is unclear which method for defining the region of interest (ROI) should be used for this purpose. The aim of our study was to compare the functional region of interest (fROI) method to both the lung area estimation method (LAEM) and no ROI when analysing global parameters of ventilation inhomogeneity. We assumed that a good method for ROI determination would lead to a high discriminatory power for ventilation inhomogeneity, as defined by the area under the receiver operating characteristics curve (AUC), comparing patients suffering from ARDS and control patients without pulmonary pathologies. METHODS: We retrospectively analysed EIT data from 24 ARDS patients and 12 control patients without pulmonary pathology. In all patients, a standardized low-flow-pressure volume maneuver had been performed and was used for EIT image generation. We compared the AUC for global inhomogeneity (GI) index and coefficient of variation (CV) between ARDS and control patients using all EIT image pixels, the fROI method and the LAEM for ROI determination. RESULTS: When analysing all EIT image pixels, we found an acceptable AUC both for the GI index (AUC = 0.76; 95% confidence interval (CI) 0.58–0.94) and the CV (AUC = 0.74; 95% CI 0.55–0.92). With the fROI method, we found a deteriorating AUC with increasing threshold criteria. With the LAEM, we found the best AUC both for the GI index (AUC = 0.89; 95% CI 0.78–1.0) and the CV (AUC = 0.89; 95% CI 0.78–1.0) using a threshold criterion of 50% of the maximum tidal impedance change. CONCLUSION: In the assessment of ventilation inhomogeneity with EIT, functional regions of interest obscure the difference between patients with ARDS and control patients without pulmonary pathologies. The LAEM is preferable to the fROI method when assessing ventilation inhomogeneity.
format Online
Article
Text
id pubmed-4806869
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48068692016-03-25 Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies Becher, Tobias Vogt, Barbara Kott, Matthias Schädler, Dirk Weiler, Norbert Frerichs, Inéz PLoS One Research Article INTRODUCTION: Patients with acute respiratory distress syndrome (ARDS) typically show a high degree of ventilation inhomogeneity, which is associated with morbidity and unfavorable outcomes. Electrical impedance tomography (EIT) is able to detect ventilation inhomogeneity, but it is unclear which method for defining the region of interest (ROI) should be used for this purpose. The aim of our study was to compare the functional region of interest (fROI) method to both the lung area estimation method (LAEM) and no ROI when analysing global parameters of ventilation inhomogeneity. We assumed that a good method for ROI determination would lead to a high discriminatory power for ventilation inhomogeneity, as defined by the area under the receiver operating characteristics curve (AUC), comparing patients suffering from ARDS and control patients without pulmonary pathologies. METHODS: We retrospectively analysed EIT data from 24 ARDS patients and 12 control patients without pulmonary pathology. In all patients, a standardized low-flow-pressure volume maneuver had been performed and was used for EIT image generation. We compared the AUC for global inhomogeneity (GI) index and coefficient of variation (CV) between ARDS and control patients using all EIT image pixels, the fROI method and the LAEM for ROI determination. RESULTS: When analysing all EIT image pixels, we found an acceptable AUC both for the GI index (AUC = 0.76; 95% confidence interval (CI) 0.58–0.94) and the CV (AUC = 0.74; 95% CI 0.55–0.92). With the fROI method, we found a deteriorating AUC with increasing threshold criteria. With the LAEM, we found the best AUC both for the GI index (AUC = 0.89; 95% CI 0.78–1.0) and the CV (AUC = 0.89; 95% CI 0.78–1.0) using a threshold criterion of 50% of the maximum tidal impedance change. CONCLUSION: In the assessment of ventilation inhomogeneity with EIT, functional regions of interest obscure the difference between patients with ARDS and control patients without pulmonary pathologies. The LAEM is preferable to the fROI method when assessing ventilation inhomogeneity. Public Library of Science 2016-03-24 /pmc/articles/PMC4806869/ /pubmed/27010320 http://dx.doi.org/10.1371/journal.pone.0152267 Text en © 2016 Becher et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Becher, Tobias
Vogt, Barbara
Kott, Matthias
Schädler, Dirk
Weiler, Norbert
Frerichs, Inéz
Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
title Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
title_full Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
title_fullStr Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
title_full_unstemmed Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
title_short Functional Regions of Interest in Electrical Impedance Tomography: A Secondary Analysis of Two Clinical Studies
title_sort functional regions of interest in electrical impedance tomography: a secondary analysis of two clinical studies
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4806869/
https://www.ncbi.nlm.nih.gov/pubmed/27010320
http://dx.doi.org/10.1371/journal.pone.0152267
work_keys_str_mv AT bechertobias functionalregionsofinterestinelectricalimpedancetomographyasecondaryanalysisoftwoclinicalstudies
AT vogtbarbara functionalregionsofinterestinelectricalimpedancetomographyasecondaryanalysisoftwoclinicalstudies
AT kottmatthias functionalregionsofinterestinelectricalimpedancetomographyasecondaryanalysisoftwoclinicalstudies
AT schadlerdirk functionalregionsofinterestinelectricalimpedancetomographyasecondaryanalysisoftwoclinicalstudies
AT weilernorbert functionalregionsofinterestinelectricalimpedancetomographyasecondaryanalysisoftwoclinicalstudies
AT frerichsinez functionalregionsofinterestinelectricalimpedancetomographyasecondaryanalysisoftwoclinicalstudies