Cargando…

Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial

OBJECTIVE: Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. METHODS: In this prospective preliminary clinic...

Descripción completa

Detalles Bibliográficos
Autores principales: Sobouti, Farhad, Rakhshan, Vahid, Saravi, Mahdi Gholamrezaei, Zamanian, Ali, Shariati, Mahsa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association of Orthodontists 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4807147/
https://www.ncbi.nlm.nih.gov/pubmed/27019825
http://dx.doi.org/10.4041/kjod.2016.46.2.104
_version_ 1782423350839083008
author Sobouti, Farhad
Rakhshan, Vahid
Saravi, Mahdi Gholamrezaei
Zamanian, Ali
Shariati, Mahsa
author_facet Sobouti, Farhad
Rakhshan, Vahid
Saravi, Mahdi Gholamrezaei
Zamanian, Ali
Shariati, Mahsa
author_sort Sobouti, Farhad
collection PubMed
description OBJECTIVE: Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. METHODS: In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (α = 0.05). RESULTS: In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). CONCLUSIONS: Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results.
format Online
Article
Text
id pubmed-4807147
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Korean Association of Orthodontists
record_format MEDLINE/PubMed
spelling pubmed-48071472016-03-27 Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial Sobouti, Farhad Rakhshan, Vahid Saravi, Mahdi Gholamrezaei Zamanian, Ali Shariati, Mahsa Korean J Orthod Original Article OBJECTIVE: Traditional retainers (both metal and fiber-reinforced composite [FRC]) have limitations, and a retainer made from more flexible ligature wires might be advantageous. We aimed to compare an experimental design with two traditional retainers. METHODS: In this prospective preliminary clinical trial, 150 post-treatment patients were enrolled and randomly divided into three groups of 50 patients each to receive mandibular canine-to-canine retainers made of FRC, flexible spiral wire (FSW), and twisted wire (TW). The patients were monitored monthly. The time at which the first signs of breakage/debonding were detected was recorded. The success rates of the retainers were compared using chi-squared, Kaplan-Meier, and Cox proportional-hazard regression analyses (α = 0.05). RESULTS: In total, 42 patients in the FRC group, 41 in the FSW group, and 45 in the TW group completed the study. The 2-year failure rates were 35.7% in the FRC group, 26.8% in the FSW group, and 17.8% in the TW group. These rates differed insignificantly (chi-squared p = 0.167). According to the Kaplan-Meier analysis, failure occurred at 19.95 months in the FRC group, 21.37 months in the FSW group, and 22.36 months in the TW group. The differences between the survival rates in the three groups were not significant (Cox regression p = 0.146). CONCLUSIONS: Although the failure rate of the experimental retainer was two times lower than that of the FRC retainer, the difference was not statistically significant. The experimental TW retainer was successful, and larger studies are warranted to verify these results. Korean Association of Orthodontists 2016-03 2016-03-18 /pmc/articles/PMC4807147/ /pubmed/27019825 http://dx.doi.org/10.4041/kjod.2016.46.2.104 Text en © 2016 The Korean Association of Orthodontists. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Sobouti, Farhad
Rakhshan, Vahid
Saravi, Mahdi Gholamrezaei
Zamanian, Ali
Shariati, Mahsa
Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial
title Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial
title_full Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial
title_fullStr Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial
title_full_unstemmed Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial
title_short Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial
title_sort two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4807147/
https://www.ncbi.nlm.nih.gov/pubmed/27019825
http://dx.doi.org/10.4041/kjod.2016.46.2.104
work_keys_str_mv AT soboutifarhad twoyearsurvivalanalysisoftwistedwirefixedretainerversusspiralwireandfiberreinforcedcompositeretainersapreliminaryexplorativesingleblindrandomizedclinicaltrial
AT rakhshanvahid twoyearsurvivalanalysisoftwistedwirefixedretainerversusspiralwireandfiberreinforcedcompositeretainersapreliminaryexplorativesingleblindrandomizedclinicaltrial
AT saravimahdigholamrezaei twoyearsurvivalanalysisoftwistedwirefixedretainerversusspiralwireandfiberreinforcedcompositeretainersapreliminaryexplorativesingleblindrandomizedclinicaltrial
AT zamanianali twoyearsurvivalanalysisoftwistedwirefixedretainerversusspiralwireandfiberreinforcedcompositeretainersapreliminaryexplorativesingleblindrandomizedclinicaltrial
AT shariatimahsa twoyearsurvivalanalysisoftwistedwirefixedretainerversusspiralwireandfiberreinforcedcompositeretainersapreliminaryexplorativesingleblindrandomizedclinicaltrial