Cargando…

Rinne test: does the tuning fork position affect the sound amplitude at the ear?

BACKGROUND: Guidelines and text-book descriptions of the Rinne test advise orienting the tuning fork tines in parallel with the longitudinal axis of the external auditory canal (EAC), presumably to maximise the amplitude of the air conducted sound signal at the ear. Whether the orientation of the tu...

Descripción completa

Detalles Bibliográficos
Autores principales: Butskiy, Oleksandr, Ng, Denny, Hodgson, Murray, Nunez, Desmond A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4807550/
https://www.ncbi.nlm.nih.gov/pubmed/27013057
http://dx.doi.org/10.1186/s40463-016-0133-7
_version_ 1782423394197700608
author Butskiy, Oleksandr
Ng, Denny
Hodgson, Murray
Nunez, Desmond A.
author_facet Butskiy, Oleksandr
Ng, Denny
Hodgson, Murray
Nunez, Desmond A.
author_sort Butskiy, Oleksandr
collection PubMed
description BACKGROUND: Guidelines and text-book descriptions of the Rinne test advise orienting the tuning fork tines in parallel with the longitudinal axis of the external auditory canal (EAC), presumably to maximise the amplitude of the air conducted sound signal at the ear. Whether the orientation of the tuning fork tines affects the amplitude of the sound signal at the ear in clinical practice has not been previously reported. The present study had two goals: determine if (1) there is clinician variability in tuning fork placement when presenting the air-conduction stimulus during the Rinne test; (2) the orientation of the tuning fork tines, parallel versus perpendicular to the EAC, affects the sound amplitude at the ear. METHODS: To assess the variability in performing the Rinne test, the Canadian Society of Otolaryngology – Head and Neck Surgery members were surveyed. The amplitudes of the sound delivered to the tympanic membrane with the activated tuning fork tines held in parallel, and perpendicular to, the longitudinal axis of the EAC were measured using a Knowles Electronics Mannequin for Acoustic Research (KEMAR) with the microphone of a sound level meter inserted in the pinna insert. RESULTS: 47.4 and 44.8 % of 116 survey responders reported placing the fork parallel and perpendicular to the EAC respectively. The sound intensity (sound-pressure level) recorded at the tympanic membrane with the 512 Hz tuning fork tines in parallel with as opposed to perpendicular to the EAC was louder by 2.5 dB (95 % CI: 1.35, 3.65 dB; p < 0.0001) for the fundamental frequency (512 Hz), and by 4.94 dB (95 % CI: 3.10, 6.78 dB; p < 0.0001) and 3.70 dB (95 % CI: 1.62, 5.78 dB; p = .001) for the two harmonic (non-fundamental) frequencies (1 and 3.15 kHz), respectively. The 256 Hz tuning fork in parallel with the EAC as opposed to perpendicular to was louder by 0.83 dB (95 % CI: −0.26, 1.93 dB; p = 0.14) for the fundamental frequency (256 Hz), and by 4.28 dB (95 % CI: 2.65, 5.90 dB; p < 0.001) and 1.93 dB (95 % CI: 0.26, 3.61 dB; p = .02) for the two harmonic frequencies (500 and 4 kHz) respectively. CONCLUSIONS: Clinicians vary in their orientation of the tuning fork tines in relation to the EAC when performing the Rinne test. Placement of the tuning fork tines in parallel as opposed to perpendicular to the EAC results in a higher sound amplitude at the level of the tympanic membrane.
format Online
Article
Text
id pubmed-4807550
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48075502016-03-25 Rinne test: does the tuning fork position affect the sound amplitude at the ear? Butskiy, Oleksandr Ng, Denny Hodgson, Murray Nunez, Desmond A. J Otolaryngol Head Neck Surg Original Research Article BACKGROUND: Guidelines and text-book descriptions of the Rinne test advise orienting the tuning fork tines in parallel with the longitudinal axis of the external auditory canal (EAC), presumably to maximise the amplitude of the air conducted sound signal at the ear. Whether the orientation of the tuning fork tines affects the amplitude of the sound signal at the ear in clinical practice has not been previously reported. The present study had two goals: determine if (1) there is clinician variability in tuning fork placement when presenting the air-conduction stimulus during the Rinne test; (2) the orientation of the tuning fork tines, parallel versus perpendicular to the EAC, affects the sound amplitude at the ear. METHODS: To assess the variability in performing the Rinne test, the Canadian Society of Otolaryngology – Head and Neck Surgery members were surveyed. The amplitudes of the sound delivered to the tympanic membrane with the activated tuning fork tines held in parallel, and perpendicular to, the longitudinal axis of the EAC were measured using a Knowles Electronics Mannequin for Acoustic Research (KEMAR) with the microphone of a sound level meter inserted in the pinna insert. RESULTS: 47.4 and 44.8 % of 116 survey responders reported placing the fork parallel and perpendicular to the EAC respectively. The sound intensity (sound-pressure level) recorded at the tympanic membrane with the 512 Hz tuning fork tines in parallel with as opposed to perpendicular to the EAC was louder by 2.5 dB (95 % CI: 1.35, 3.65 dB; p < 0.0001) for the fundamental frequency (512 Hz), and by 4.94 dB (95 % CI: 3.10, 6.78 dB; p < 0.0001) and 3.70 dB (95 % CI: 1.62, 5.78 dB; p = .001) for the two harmonic (non-fundamental) frequencies (1 and 3.15 kHz), respectively. The 256 Hz tuning fork in parallel with the EAC as opposed to perpendicular to was louder by 0.83 dB (95 % CI: −0.26, 1.93 dB; p = 0.14) for the fundamental frequency (256 Hz), and by 4.28 dB (95 % CI: 2.65, 5.90 dB; p < 0.001) and 1.93 dB (95 % CI: 0.26, 3.61 dB; p = .02) for the two harmonic frequencies (500 and 4 kHz) respectively. CONCLUSIONS: Clinicians vary in their orientation of the tuning fork tines in relation to the EAC when performing the Rinne test. Placement of the tuning fork tines in parallel as opposed to perpendicular to the EAC results in a higher sound amplitude at the level of the tympanic membrane. BioMed Central 2016-03-24 /pmc/articles/PMC4807550/ /pubmed/27013057 http://dx.doi.org/10.1186/s40463-016-0133-7 Text en © Butskiy et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Research Article
Butskiy, Oleksandr
Ng, Denny
Hodgson, Murray
Nunez, Desmond A.
Rinne test: does the tuning fork position affect the sound amplitude at the ear?
title Rinne test: does the tuning fork position affect the sound amplitude at the ear?
title_full Rinne test: does the tuning fork position affect the sound amplitude at the ear?
title_fullStr Rinne test: does the tuning fork position affect the sound amplitude at the ear?
title_full_unstemmed Rinne test: does the tuning fork position affect the sound amplitude at the ear?
title_short Rinne test: does the tuning fork position affect the sound amplitude at the ear?
title_sort rinne test: does the tuning fork position affect the sound amplitude at the ear?
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4807550/
https://www.ncbi.nlm.nih.gov/pubmed/27013057
http://dx.doi.org/10.1186/s40463-016-0133-7
work_keys_str_mv AT butskiyoleksandr rinnetestdoesthetuningforkpositionaffectthesoundamplitudeattheear
AT ngdenny rinnetestdoesthetuningforkpositionaffectthesoundamplitudeattheear
AT hodgsonmurray rinnetestdoesthetuningforkpositionaffectthesoundamplitudeattheear
AT nunezdesmonda rinnetestdoesthetuningforkpositionaffectthesoundamplitudeattheear