Cargando…

Effect of retention design of artificial teeth and implant-supported titanium CAD-CAM structures on fracture resistance

BACKGROUND: For implant-supported hybrid prostheses, high mastication forces and reduced acrylic resin thickness over a metal substructure often cause failures arising from tooth or resin fractures. To assay fracture resistance of artificial teeth and resin in implant-supported hybrid prostheses in...

Descripción completa

Detalles Bibliográficos
Autores principales: Ladetzki, Kristin, Mateos-Palacios, Rocío, Pascual-Moscardó, Agustín, Selva-Otaolaurruchi, Eduardo J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4808303/
https://www.ncbi.nlm.nih.gov/pubmed/27034748
http://dx.doi.org/10.4317/jced.52228
Descripción
Sumario:BACKGROUND: For implant-supported hybrid prostheses, high mastication forces and reduced acrylic resin thickness over a metal substructure often cause failures arising from tooth or resin fractures. To assay fracture resistance of artificial teeth and resin in implant-supported hybrid prostheses in relation to the titanium structure and retention design supporting teeth. MATERIAL AND METHODS: 40 specimens bearing incisors were divided into four groups according to the titanium structure supporting the teeth and the type of load force applied: Group I (Control; n=10): Application of static loading to ten incisors set over a metal structure with internal retention. Group II (Control; n=10): Application of static loading to ten incisors set over a metal structure with external retention. The remaining study specimens (n=20) were subjected to 120,000 masticatory and thermal cycles in a chewing simulator. Afterwards, static loading was applied until the point of fracture using an Instron machine. Group III (Study; n=10): Application of dynamic and static loading to ten incisors set over a metal structure with internal retention. Group IV (Study; n=10): Application of dynamic and static loading to ten incisors set over a metal structure with external retention. Data obtained for the four groups was analyzed and compared, determining the type of fracture (cohesive or adhesive) using a reflected light microscope. RESULTS: Statistical analysis confirmed that there were significant differences in fracture resistance between the four groups. External retention was found to have more fracture resistance than the internal retention. CONCLUSIONS: Hybrid prostheses with titanium substructures and external retention obtained significantly better results than samples with internal retention. Key words:Chewing simulator, thermocycler, fatigue, implant-supported hybrid prosthesis, acrylic teeth, fracture, metal structure design.