Cargando…

An Unexpected Complication after Headless Compression Screw Fixation of an Osteochondral Fracture of Patella

This study evaluated complications associated with implant depth in headless compression screw treatment of an osteochondral fracture associated with a traumatic patellar dislocation in a 21-year-old woman. Computed tomography and X-rays showed one lateral fracture fragment measuring 25 × 16 mm. Ost...

Descripción completa

Detalles Bibliográficos
Autores principales: Aydoğmuş, Suavi, Duymuş, Tahir Mutlu, Keçeci, Tolga
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4808665/
https://www.ncbi.nlm.nih.gov/pubmed/27051547
http://dx.doi.org/10.1155/2016/7290104
Descripción
Sumario:This study evaluated complications associated with implant depth in headless compression screw treatment of an osteochondral fracture associated with a traumatic patellar dislocation in a 21-year-old woman. Computed tomography and X-rays showed one lateral fracture fragment measuring 25 × 16 mm. Osteosynthesis was performed with two headless compression screws. Five months later, the screws were removed because of patella-femoral implant friction. We recommend that the screw heads be embedded to a depth of at least 3 mm below the cartilage surface. Further clinical studies need to examine the variation in cartilage thickness in the fracture fragment.