Cargando…

Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy

Myocardial perfusion single photon emission computed tomography (SPECT) is a powerful test of evaluation for coronary artery disease, but subdiaphragmatic radiotracer activity often interferes with the interpretation of inferior wall findings. This study aims to evaluate the effectiveness of using s...

Descripción completa

Detalles Bibliográficos
Autores principales: Theerakulpisut, Daris, Chotipanich, Chanisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4809162/
https://www.ncbi.nlm.nih.gov/pubmed/27134559
http://dx.doi.org/10.4103/1450-1147.173898
_version_ 1782423596996493312
author Theerakulpisut, Daris
Chotipanich, Chanisa
author_facet Theerakulpisut, Daris
Chotipanich, Chanisa
author_sort Theerakulpisut, Daris
collection PubMed
description Myocardial perfusion single photon emission computed tomography (SPECT) is a powerful test of evaluation for coronary artery disease, but subdiaphragmatic radiotracer activity often interferes with the interpretation of inferior wall findings. This study aims to evaluate the effectiveness of using software elimination of the subdiaphragmatic activity for the assessment of its efficacy in the correctness of image interpretation and the overall image quality of myocardial perfusion scintigraphy (MPS). MPS studies from January 2010 to October 2012 at our institution were reviewed. Thirty-two SPECT studies were included, all of which had significant subdiaphragmatic activity in the first scan and needed to be delayed to let the activity clear. Each scan was interpreted by using semiquantitative scoring in 17 segments according to the degree of radiotracer uptake. The first scan, which had interfering activity, was manipulated by masking out the unwanted activity with software native to our image processing software suite. The manipulated images were then compared with delayed images of the same patient, of which the subdiaphragmatic activity was spontaneously cleared with time. The first scan masked by software correlated with the delayed scan for myocardial regions supplied by the left circumflex (LCx) and right coronary artery (RCA), but not the left anterior descending (LAD). However, the quality of the masked scans was perceived by the observer to be better in terms of quality and ease of interpretation. Using software to mask out unwanted subdiaphragmatic activity has no detrimental effect on the interpretation of MPS images when compared with delayed scanning, but it can improve subjective scan quality and ease of interpretation.
format Online
Article
Text
id pubmed-4809162
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48091622016-05-01 Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy Theerakulpisut, Daris Chotipanich, Chanisa World J Nucl Med Original Article Myocardial perfusion single photon emission computed tomography (SPECT) is a powerful test of evaluation for coronary artery disease, but subdiaphragmatic radiotracer activity often interferes with the interpretation of inferior wall findings. This study aims to evaluate the effectiveness of using software elimination of the subdiaphragmatic activity for the assessment of its efficacy in the correctness of image interpretation and the overall image quality of myocardial perfusion scintigraphy (MPS). MPS studies from January 2010 to October 2012 at our institution were reviewed. Thirty-two SPECT studies were included, all of which had significant subdiaphragmatic activity in the first scan and needed to be delayed to let the activity clear. Each scan was interpreted by using semiquantitative scoring in 17 segments according to the degree of radiotracer uptake. The first scan, which had interfering activity, was manipulated by masking out the unwanted activity with software native to our image processing software suite. The manipulated images were then compared with delayed images of the same patient, of which the subdiaphragmatic activity was spontaneously cleared with time. The first scan masked by software correlated with the delayed scan for myocardial regions supplied by the left circumflex (LCx) and right coronary artery (RCA), but not the left anterior descending (LAD). However, the quality of the masked scans was perceived by the observer to be better in terms of quality and ease of interpretation. Using software to mask out unwanted subdiaphragmatic activity has no detrimental effect on the interpretation of MPS images when compared with delayed scanning, but it can improve subjective scan quality and ease of interpretation. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4809162/ /pubmed/27134559 http://dx.doi.org/10.4103/1450-1147.173898 Text en Copyright: © World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution NonCommercial ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Theerakulpisut, Daris
Chotipanich, Chanisa
Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy
title Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy
title_full Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy
title_fullStr Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy
title_full_unstemmed Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy
title_short Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy
title_sort comparison between postprocessing software and repeated scanning to eliminate subdiaphragmatic activity in myocardial perfusion scintigraphy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4809162/
https://www.ncbi.nlm.nih.gov/pubmed/27134559
http://dx.doi.org/10.4103/1450-1147.173898
work_keys_str_mv AT theerakulpisutdaris comparisonbetweenpostprocessingsoftwareandrepeatedscanningtoeliminatesubdiaphragmaticactivityinmyocardialperfusionscintigraphy
AT chotipanichchanisa comparisonbetweenpostprocessingsoftwareandrepeatedscanningtoeliminatesubdiaphragmaticactivityinmyocardialperfusionscintigraphy