Cargando…

Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses

PURPOSE: To evaluate the repeatability of power profiles measured on NIMO TR1504 (Lambda-X, Belgium) and investigate the effects of lens decentration on the power profiles for single vision (SV), bifocal (BF) and multifocal (MF) contact lenses. METHODS: Accuracy of the sphere power was evaluated usi...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Eon, Bakaraju, Ravi C., Ehrmann, Klaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4811992/
https://www.ncbi.nlm.nih.gov/pubmed/26590009
http://dx.doi.org/10.1016/j.optom.2015.10.005
_version_ 1782424071655391232
author Kim, Eon
Bakaraju, Ravi C.
Ehrmann, Klaus
author_facet Kim, Eon
Bakaraju, Ravi C.
Ehrmann, Klaus
author_sort Kim, Eon
collection PubMed
description PURPOSE: To evaluate the repeatability of power profiles measured on NIMO TR1504 (Lambda-X, Belgium) and investigate the effects of lens decentration on the power profiles for single vision (SV), bifocal (BF) and multifocal (MF) contact lenses. METHODS: Accuracy of the sphere power was evaluated using single vision BK-7 calibration glass lenses of six minus and six plus powers. Three SV and four BF/MF contact lenses – three lenses each, were measured five times to calculate the coefficients of repeatability (COR) of the instrument. The COR was computed for each chord position, lens design, prescription power and operator. One lens from each type was measured with a deliberate decentration up to ±0.5 mm in 0.1 mm steps. RESULTS: For all lenses, the COR varied across different regions of the half-chord position. In general, SV lenses showed lower COR compared to the BF/MF group lenses. There were no noticeable trends of COR between prescription powers for SV and BF/MF lenses. The shape of the power profiles was not affected when lenses were deliberately decentered for all SV and PureVision MF lenses. However, for Acuvue BF lenses, the peak to trough amplitude of the power profiles flattened up to 1.00 D. CONCLUSION: The COR across the half-chord of the optic zone diameter was mostly within clinical relevance except for the central 0.5 mm half-chord position. COR were dependent on the lens type, whereby BF/MF group produced higher COR than SV lenses. The effects of deliberate decentration on the shape of power profiles were pronounced for lenses where the profiles had sharp transitions of power.
format Online
Article
Text
id pubmed-4811992
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-48119922016-04-11 Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses Kim, Eon Bakaraju, Ravi C. Ehrmann, Klaus J Optom Original Article PURPOSE: To evaluate the repeatability of power profiles measured on NIMO TR1504 (Lambda-X, Belgium) and investigate the effects of lens decentration on the power profiles for single vision (SV), bifocal (BF) and multifocal (MF) contact lenses. METHODS: Accuracy of the sphere power was evaluated using single vision BK-7 calibration glass lenses of six minus and six plus powers. Three SV and four BF/MF contact lenses – three lenses each, were measured five times to calculate the coefficients of repeatability (COR) of the instrument. The COR was computed for each chord position, lens design, prescription power and operator. One lens from each type was measured with a deliberate decentration up to ±0.5 mm in 0.1 mm steps. RESULTS: For all lenses, the COR varied across different regions of the half-chord position. In general, SV lenses showed lower COR compared to the BF/MF group lenses. There were no noticeable trends of COR between prescription powers for SV and BF/MF lenses. The shape of the power profiles was not affected when lenses were deliberately decentered for all SV and PureVision MF lenses. However, for Acuvue BF lenses, the peak to trough amplitude of the power profiles flattened up to 1.00 D. CONCLUSION: The COR across the half-chord of the optic zone diameter was mostly within clinical relevance except for the central 0.5 mm half-chord position. COR were dependent on the lens type, whereby BF/MF group produced higher COR than SV lenses. The effects of deliberate decentration on the shape of power profiles were pronounced for lenses where the profiles had sharp transitions of power. Elsevier 2016 2015-11-14 /pmc/articles/PMC4811992/ /pubmed/26590009 http://dx.doi.org/10.1016/j.optom.2015.10.005 Text en © 2015 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Kim, Eon
Bakaraju, Ravi C.
Ehrmann, Klaus
Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses
title Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses
title_full Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses
title_fullStr Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses
title_full_unstemmed Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses
title_short Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses
title_sort reliability of power profiles measured on nimo tr1504 (lambda-x) and effects of lens decentration for single vision, bifocal and multifocal contact lenses
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4811992/
https://www.ncbi.nlm.nih.gov/pubmed/26590009
http://dx.doi.org/10.1016/j.optom.2015.10.005
work_keys_str_mv AT kimeon reliabilityofpowerprofilesmeasuredonnimotr1504lambdaxandeffectsoflensdecentrationforsinglevisionbifocalandmultifocalcontactlenses
AT bakarajuravic reliabilityofpowerprofilesmeasuredonnimotr1504lambdaxandeffectsoflensdecentrationforsinglevisionbifocalandmultifocalcontactlenses
AT ehrmannklaus reliabilityofpowerprofilesmeasuredonnimotr1504lambdaxandeffectsoflensdecentrationforsinglevisionbifocalandmultifocalcontactlenses