Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery
The pipeline embolization device has emerged as an important endovascular option. This is in part due to safety, efficacy, and possibly the ability to shorten the operative time considerably. With this new technology, some limitations are emerging as experience accumulates. We report three cases of...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4812271/ https://www.ncbi.nlm.nih.gov/pubmed/27069709 http://dx.doi.org/10.1155/2016/4691275 |
_version_ | 1782424138543005696 |
---|---|
author | Zanaty, Mario Chalouhi, Nohra Starke, Robert M. Jabbour, Pascal Ryken, Katherine O. Bulsara, Ketan R. Hasan, David |
author_facet | Zanaty, Mario Chalouhi, Nohra Starke, Robert M. Jabbour, Pascal Ryken, Katherine O. Bulsara, Ketan R. Hasan, David |
author_sort | Zanaty, Mario |
collection | PubMed |
description | The pipeline embolization device has emerged as an important endovascular option. This is in part due to safety, efficacy, and possibly the ability to shorten the operative time considerably. With this new technology, some limitations are emerging as experience accumulates. We report three cases of posterior communicating (PCOM) artery aneurysms associated with fetal posterior cerebral artery where pipeline embolization was unsuccessful in obliterating the aneurysms. PCOM artery aneurysms associated with a fetal PCA should be managed either by microsurgical clipping or coiling when feasible. |
format | Online Article Text |
id | pubmed-4812271 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-48122712016-04-11 Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery Zanaty, Mario Chalouhi, Nohra Starke, Robert M. Jabbour, Pascal Ryken, Katherine O. Bulsara, Ketan R. Hasan, David Case Rep Vasc Med Case Report The pipeline embolization device has emerged as an important endovascular option. This is in part due to safety, efficacy, and possibly the ability to shorten the operative time considerably. With this new technology, some limitations are emerging as experience accumulates. We report three cases of posterior communicating (PCOM) artery aneurysms associated with fetal posterior cerebral artery where pipeline embolization was unsuccessful in obliterating the aneurysms. PCOM artery aneurysms associated with a fetal PCA should be managed either by microsurgical clipping or coiling when feasible. Hindawi Publishing Corporation 2016 2016-03-16 /pmc/articles/PMC4812271/ /pubmed/27069709 http://dx.doi.org/10.1155/2016/4691275 Text en Copyright © 2016 Mario Zanaty et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Zanaty, Mario Chalouhi, Nohra Starke, Robert M. Jabbour, Pascal Ryken, Katherine O. Bulsara, Ketan R. Hasan, David Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery |
title | Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery |
title_full | Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery |
title_fullStr | Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery |
title_full_unstemmed | Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery |
title_short | Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery |
title_sort | failure of the pipeline embolization device in posterior communicating artery aneurysms associated with a fetal posterior cerebral artery |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4812271/ https://www.ncbi.nlm.nih.gov/pubmed/27069709 http://dx.doi.org/10.1155/2016/4691275 |
work_keys_str_mv | AT zanatymario failureofthepipelineembolizationdeviceinposteriorcommunicatingarteryaneurysmsassociatedwithafetalposteriorcerebralartery AT chalouhinohra failureofthepipelineembolizationdeviceinposteriorcommunicatingarteryaneurysmsassociatedwithafetalposteriorcerebralartery AT starkerobertm failureofthepipelineembolizationdeviceinposteriorcommunicatingarteryaneurysmsassociatedwithafetalposteriorcerebralartery AT jabbourpascal failureofthepipelineembolizationdeviceinposteriorcommunicatingarteryaneurysmsassociatedwithafetalposteriorcerebralartery AT rykenkatherineo failureofthepipelineembolizationdeviceinposteriorcommunicatingarteryaneurysmsassociatedwithafetalposteriorcerebralartery AT bulsaraketanr failureofthepipelineembolizationdeviceinposteriorcommunicatingarteryaneurysmsassociatedwithafetalposteriorcerebralartery AT hasandavid failureofthepipelineembolizationdeviceinposteriorcommunicatingarteryaneurysmsassociatedwithafetalposteriorcerebralartery |