Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital
Background. Contrast induced nephropathy (CIN) is common cause of hospital acquired renal failure, defined as iatrogenic deterioration of renal function following intravascular contrast administration in the absence of another nephrotoxic event. Objectives. Objectives were to calculate incidence of...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4812473/ https://www.ncbi.nlm.nih.gov/pubmed/27069686 http://dx.doi.org/10.1155/2016/8792984 |
_version_ | 1782424181148745728 |
---|---|
author | Bhatt, Shuchi Rajpal, Nipun Rathi, Vineeta Avasthi, Rajneesh |
author_facet | Bhatt, Shuchi Rajpal, Nipun Rathi, Vineeta Avasthi, Rajneesh |
author_sort | Bhatt, Shuchi |
collection | PubMed |
description | Background. Contrast induced nephropathy (CIN) is common cause of hospital acquired renal failure, defined as iatrogenic deterioration of renal function following intravascular contrast administration in the absence of another nephrotoxic event. Objectives. Objectives were to calculate incidence of CIN with routine IV contrast usage and to identify its risk factors. Materials and Methods. Study was conducted on 250 patients (having eGFR ≥ 45 mL/min/1.73 m(2)) receiving intravenous contrast. Various clinical risk factors and details of contrast media were recorded. Patients showing 25% increase in postprocedural serum creatinine value or an absolute increase of 0.5 mg/dL (44.2 mmol/L) were diagnosed as having CIN. Results and Conclusions. Postprocedural serum creatinine showed significant increase from baseline levels. 25 patients (10%) developed CIN. CIN was transient in 21 (84%) patients developing CIN. One patient (4%) developed renal failure and another died due to unknown cause. Dehydration, preexisting renal disease, cardiac failure, previous contrast administration, and volume of contrast had significant correlation with development of CIN (p < 0.05); whereas demographic variables, baseline serum creatinine/eGFR, previous renal surgery, diabetes mellitus, hypertension, nephrotoxic drug intake, abnormal routine hematology, and contrast characteristics had no correlation with CIN. CIN is a matter of concern even in routine imaging requiring intravenous contrast media, in our set-up. |
format | Online Article Text |
id | pubmed-4812473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-48124732016-04-11 Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital Bhatt, Shuchi Rajpal, Nipun Rathi, Vineeta Avasthi, Rajneesh Radiol Res Pract Research Article Background. Contrast induced nephropathy (CIN) is common cause of hospital acquired renal failure, defined as iatrogenic deterioration of renal function following intravascular contrast administration in the absence of another nephrotoxic event. Objectives. Objectives were to calculate incidence of CIN with routine IV contrast usage and to identify its risk factors. Materials and Methods. Study was conducted on 250 patients (having eGFR ≥ 45 mL/min/1.73 m(2)) receiving intravenous contrast. Various clinical risk factors and details of contrast media were recorded. Patients showing 25% increase in postprocedural serum creatinine value or an absolute increase of 0.5 mg/dL (44.2 mmol/L) were diagnosed as having CIN. Results and Conclusions. Postprocedural serum creatinine showed significant increase from baseline levels. 25 patients (10%) developed CIN. CIN was transient in 21 (84%) patients developing CIN. One patient (4%) developed renal failure and another died due to unknown cause. Dehydration, preexisting renal disease, cardiac failure, previous contrast administration, and volume of contrast had significant correlation with development of CIN (p < 0.05); whereas demographic variables, baseline serum creatinine/eGFR, previous renal surgery, diabetes mellitus, hypertension, nephrotoxic drug intake, abnormal routine hematology, and contrast characteristics had no correlation with CIN. CIN is a matter of concern even in routine imaging requiring intravenous contrast media, in our set-up. Hindawi Publishing Corporation 2016 2016-03-16 /pmc/articles/PMC4812473/ /pubmed/27069686 http://dx.doi.org/10.1155/2016/8792984 Text en Copyright © 2016 Shuchi Bhatt et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bhatt, Shuchi Rajpal, Nipun Rathi, Vineeta Avasthi, Rajneesh Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital |
title | Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital |
title_full | Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital |
title_fullStr | Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital |
title_full_unstemmed | Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital |
title_short | Contrast Induced Nephropathy with Intravenous Iodinated Contrast Media in Routine Diagnostic Imaging: An Initial Experience in a Tertiary Care Hospital |
title_sort | contrast induced nephropathy with intravenous iodinated contrast media in routine diagnostic imaging: an initial experience in a tertiary care hospital |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4812473/ https://www.ncbi.nlm.nih.gov/pubmed/27069686 http://dx.doi.org/10.1155/2016/8792984 |
work_keys_str_mv | AT bhattshuchi contrastinducednephropathywithintravenousiodinatedcontrastmediainroutinediagnosticimaginganinitialexperienceinatertiarycarehospital AT rajpalnipun contrastinducednephropathywithintravenousiodinatedcontrastmediainroutinediagnosticimaginganinitialexperienceinatertiarycarehospital AT rathivineeta contrastinducednephropathywithintravenousiodinatedcontrastmediainroutinediagnosticimaginganinitialexperienceinatertiarycarehospital AT avasthirajneesh contrastinducednephropathywithintravenousiodinatedcontrastmediainroutinediagnosticimaginganinitialexperienceinatertiarycarehospital |