Cargando…

Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods

The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma i...

Descripción completa

Detalles Bibliográficos
Autores principales: Oberfrank, Stephanie, Drechsel, Hartmut, Sinn, Stefan, Northoff, Hinnak, Gehring, Frank K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813857/
https://www.ncbi.nlm.nih.gov/pubmed/26927107
http://dx.doi.org/10.3390/s16030282
_version_ 1782424327816216576
author Oberfrank, Stephanie
Drechsel, Hartmut
Sinn, Stefan
Northoff, Hinnak
Gehring, Frank K.
author_facet Oberfrank, Stephanie
Drechsel, Hartmut
Sinn, Stefan
Northoff, Hinnak
Gehring, Frank K.
author_sort Oberfrank, Stephanie
collection PubMed
description The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor’s own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field.
format Online
Article
Text
id pubmed-4813857
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-48138572016-04-06 Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods Oberfrank, Stephanie Drechsel, Hartmut Sinn, Stefan Northoff, Hinnak Gehring, Frank K. Sensors (Basel) Article The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor’s own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field. MDPI 2016-02-24 /pmc/articles/PMC4813857/ /pubmed/26927107 http://dx.doi.org/10.3390/s16030282 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oberfrank, Stephanie
Drechsel, Hartmut
Sinn, Stefan
Northoff, Hinnak
Gehring, Frank K.
Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
title Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
title_full Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
title_fullStr Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
title_full_unstemmed Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
title_short Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
title_sort utilisation of quartz crystal microbalance sensors with dissipation (qcm-d) for a clauss fibrinogen assay in comparison with common coagulation reference methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813857/
https://www.ncbi.nlm.nih.gov/pubmed/26927107
http://dx.doi.org/10.3390/s16030282
work_keys_str_mv AT oberfrankstephanie utilisationofquartzcrystalmicrobalancesensorswithdissipationqcmdforaclaussfibrinogenassayincomparisonwithcommoncoagulationreferencemethods
AT drechselhartmut utilisationofquartzcrystalmicrobalancesensorswithdissipationqcmdforaclaussfibrinogenassayincomparisonwithcommoncoagulationreferencemethods
AT sinnstefan utilisationofquartzcrystalmicrobalancesensorswithdissipationqcmdforaclaussfibrinogenassayincomparisonwithcommoncoagulationreferencemethods
AT northoffhinnak utilisationofquartzcrystalmicrobalancesensorswithdissipationqcmdforaclaussfibrinogenassayincomparisonwithcommoncoagulationreferencemethods
AT gehringfrankk utilisationofquartzcrystalmicrobalancesensorswithdissipationqcmdforaclaussfibrinogenassayincomparisonwithcommoncoagulationreferencemethods