Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph

Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have...

Descripción completa

Detalles Bibliográficos
Autores principales: Warren, Kristen M., Harvey, Joshua R., Chon, Ki H., Mendelson, Yitzhak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813917/
https://www.ncbi.nlm.nih.gov/pubmed/26959034
http://dx.doi.org/10.3390/s16030342
_version_ 1782424344693047296
author Warren, Kristen M.
Harvey, Joshua R.
Chon, Ki H.
Mendelson, Yitzhak
author_facet Warren, Kristen M.
Harvey, Joshua R.
Chon, Ki H.
Mendelson, Yitzhak
author_sort Warren, Kristen M.
collection PubMed
description Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.
format Online
Article
Text
id pubmed-4813917
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-48139172016-04-06 Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph Warren, Kristen M. Harvey, Joshua R. Chon, Ki H. Mendelson, Yitzhak Sensors (Basel) Article Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data. MDPI 2016-03-07 /pmc/articles/PMC4813917/ /pubmed/26959034 http://dx.doi.org/10.3390/s16030342 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Warren, Kristen M.
Harvey, Joshua R.
Chon, Ki H.
Mendelson, Yitzhak
Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
title Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
title_full Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
title_fullStr Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
title_full_unstemmed Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
title_short Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
title_sort improving pulse rate measurements during random motion using a wearable multichannel reflectance photoplethysmograph
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813917/
https://www.ncbi.nlm.nih.gov/pubmed/26959034
http://dx.doi.org/10.3390/s16030342
work_keys_str_mv AT warrenkristenm improvingpulseratemeasurementsduringrandommotionusingawearablemultichannelreflectancephotoplethysmograph
AT harveyjoshuar improvingpulseratemeasurementsduringrandommotionusingawearablemultichannelreflectancephotoplethysmograph
AT chonkih improvingpulseratemeasurementsduringrandommotionusingawearablemultichannelreflectancephotoplethysmograph
AT mendelsonyitzhak improvingpulseratemeasurementsduringrandommotionusingawearablemultichannelreflectancephotoplethysmograph