Cargando…
Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling
This paper proposes a design methodology for linear actuators, considering thermal and electromagnetic coupling with geometrical and temperature constraints, that maximizes force density and minimizes force ripple. The method allows defining an actuator for given specifications in a step-by-step way...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813935/ https://www.ncbi.nlm.nih.gov/pubmed/26978370 http://dx.doi.org/10.3390/s16030360 |
_version_ | 1782424349621354496 |
---|---|
author | Eckert, Paulo Roberto Flores Filho, Aly Ferreira Perondi, Eduardo Ferri, Jeferson Goltz, Evandro |
author_facet | Eckert, Paulo Roberto Flores Filho, Aly Ferreira Perondi, Eduardo Ferri, Jeferson Goltz, Evandro |
author_sort | Eckert, Paulo Roberto |
collection | PubMed |
description | This paper proposes a design methodology for linear actuators, considering thermal and electromagnetic coupling with geometrical and temperature constraints, that maximizes force density and minimizes force ripple. The method allows defining an actuator for given specifications in a step-by-step way so that requirements are met and the temperature within the device is maintained under or equal to its maximum allowed for continuous operation. According to the proposed method, the electromagnetic and thermal models are built with quasi-static parametric finite element models. The methodology was successfully applied to the design of a linear cylindrical actuator with a dual quasi-Halbach array of permanent magnets and a moving-coil. The actuator can produce an axial force of 120 N and a stroke of 80 mm. The paper also presents a comparative analysis between results obtained considering only an electromagnetic model and the thermal-electromagnetic coupled model. This comparison shows that the final designs for both cases differ significantly, especially regarding its active volume and its electrical and magnetic loading. Although in this paper the methodology was employed to design a specific actuator, its structure can be used to design a wide range of linear devices if the parametric models are adjusted for each particular actuator. |
format | Online Article Text |
id | pubmed-4813935 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-48139352016-04-06 Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling Eckert, Paulo Roberto Flores Filho, Aly Ferreira Perondi, Eduardo Ferri, Jeferson Goltz, Evandro Sensors (Basel) Article This paper proposes a design methodology for linear actuators, considering thermal and electromagnetic coupling with geometrical and temperature constraints, that maximizes force density and minimizes force ripple. The method allows defining an actuator for given specifications in a step-by-step way so that requirements are met and the temperature within the device is maintained under or equal to its maximum allowed for continuous operation. According to the proposed method, the electromagnetic and thermal models are built with quasi-static parametric finite element models. The methodology was successfully applied to the design of a linear cylindrical actuator with a dual quasi-Halbach array of permanent magnets and a moving-coil. The actuator can produce an axial force of 120 N and a stroke of 80 mm. The paper also presents a comparative analysis between results obtained considering only an electromagnetic model and the thermal-electromagnetic coupled model. This comparison shows that the final designs for both cases differ significantly, especially regarding its active volume and its electrical and magnetic loading. Although in this paper the methodology was employed to design a specific actuator, its structure can be used to design a wide range of linear devices if the parametric models are adjusted for each particular actuator. MDPI 2016-03-11 /pmc/articles/PMC4813935/ /pubmed/26978370 http://dx.doi.org/10.3390/s16030360 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Eckert, Paulo Roberto Flores Filho, Aly Ferreira Perondi, Eduardo Ferri, Jeferson Goltz, Evandro Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling |
title | Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling |
title_full | Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling |
title_fullStr | Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling |
title_full_unstemmed | Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling |
title_short | Design Methodology of a Dual-Halbach Array Linear Actuator with Thermal-Electromagnetic Coupling |
title_sort | design methodology of a dual-halbach array linear actuator with thermal-electromagnetic coupling |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4813935/ https://www.ncbi.nlm.nih.gov/pubmed/26978370 http://dx.doi.org/10.3390/s16030360 |
work_keys_str_mv | AT eckertpauloroberto designmethodologyofadualhalbacharraylinearactuatorwiththermalelectromagneticcoupling AT floresfilhoalyferreira designmethodologyofadualhalbacharraylinearactuatorwiththermalelectromagneticcoupling AT perondieduardo designmethodologyofadualhalbacharraylinearactuatorwiththermalelectromagneticcoupling AT ferrijeferson designmethodologyofadualhalbacharraylinearactuatorwiththermalelectromagneticcoupling AT goltzevandro designmethodologyofadualhalbacharraylinearactuatorwiththermalelectromagneticcoupling |