Cargando…

Intraocular pressure in genetically distinct mice: an update and strain survey

BACKGROUND: Little is known about genetic factors affecting intraocular pressure (IOP) in mice and other mammals. The purpose of this study was to determine the IOPs of genetically distinct mouse strains, assess the effects of factors such as age, sex and time of day on IOP in specific strain backgr...

Descripción completa

Detalles Bibliográficos
Autores principales: Savinova, Olga V, Sugiyama, Fumihiro, Martin, Janice E, Tomarev, Stanislav I, Paigen, Beverly J, Smith, Richard S, John, Simon WM
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2001
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC48141/
https://www.ncbi.nlm.nih.gov/pubmed/11532192
http://dx.doi.org/10.1186/1471-2156-2-12
_version_ 1782120025480495104
author Savinova, Olga V
Sugiyama, Fumihiro
Martin, Janice E
Tomarev, Stanislav I
Paigen, Beverly J
Smith, Richard S
John, Simon WM
author_facet Savinova, Olga V
Sugiyama, Fumihiro
Martin, Janice E
Tomarev, Stanislav I
Paigen, Beverly J
Smith, Richard S
John, Simon WM
author_sort Savinova, Olga V
collection PubMed
description BACKGROUND: Little is known about genetic factors affecting intraocular pressure (IOP) in mice and other mammals. The purpose of this study was to determine the IOPs of genetically distinct mouse strains, assess the effects of factors such as age, sex and time of day on IOP in specific strain backgrounds, and to assess the effects of specific candidate gene mutations on IOP. RESULTS: Based on over 30 studied mouse strains, average IOP ranges from approximately 10 to 20 mmHg. Gender does not typically affect IOP and aging results in an IOP decrease in some strains. Most tested strains exhibit a diurnal rhythm with IOP being the highest during the dark period of the day. Homozygosity for a null allele of the carbonic anhydrase II gene (Car2(n)) does not alter IOP while homozygosity for a mutation in the leptin receptor gene (Lepr(db)) that causes obesity and diabetes results in increased IOP. Albino C57BL/6J mice homozygous for a tyrosinase mutation (Tyr(c-2J)) have higher IOPs than their pigmented counterparts. CONCLUSIONS: Genetically distinct mouse strains housed in the same environment have a broad range of IOPs. These IOP differences are likely due to interstrain genetic differences that create a powerful resource for studying the regulation of IOP. Age, time of day, obesity and diabetes have effects on mouse IOP similar to those in humans and other species. Mutations in two of the assessed candidate genes (Lepr and Tyr) result in increased IOP. These studies demonstrate that mice are a practical and powerful experimental system to study the genetics of IOP regulation and disease processes that raise IOP to harmful levels.
format Text
id pubmed-48141
institution National Center for Biotechnology Information
language English
publishDate 2001
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-481412001-09-04 Intraocular pressure in genetically distinct mice: an update and strain survey Savinova, Olga V Sugiyama, Fumihiro Martin, Janice E Tomarev, Stanislav I Paigen, Beverly J Smith, Richard S John, Simon WM BMC Genet Research Article BACKGROUND: Little is known about genetic factors affecting intraocular pressure (IOP) in mice and other mammals. The purpose of this study was to determine the IOPs of genetically distinct mouse strains, assess the effects of factors such as age, sex and time of day on IOP in specific strain backgrounds, and to assess the effects of specific candidate gene mutations on IOP. RESULTS: Based on over 30 studied mouse strains, average IOP ranges from approximately 10 to 20 mmHg. Gender does not typically affect IOP and aging results in an IOP decrease in some strains. Most tested strains exhibit a diurnal rhythm with IOP being the highest during the dark period of the day. Homozygosity for a null allele of the carbonic anhydrase II gene (Car2(n)) does not alter IOP while homozygosity for a mutation in the leptin receptor gene (Lepr(db)) that causes obesity and diabetes results in increased IOP. Albino C57BL/6J mice homozygous for a tyrosinase mutation (Tyr(c-2J)) have higher IOPs than their pigmented counterparts. CONCLUSIONS: Genetically distinct mouse strains housed in the same environment have a broad range of IOPs. These IOP differences are likely due to interstrain genetic differences that create a powerful resource for studying the regulation of IOP. Age, time of day, obesity and diabetes have effects on mouse IOP similar to those in humans and other species. Mutations in two of the assessed candidate genes (Lepr and Tyr) result in increased IOP. These studies demonstrate that mice are a practical and powerful experimental system to study the genetics of IOP regulation and disease processes that raise IOP to harmful levels. BioMed Central 2001-08-09 /pmc/articles/PMC48141/ /pubmed/11532192 http://dx.doi.org/10.1186/1471-2156-2-12 Text en Copyright © 2001 Savinova et al; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL.
spellingShingle Research Article
Savinova, Olga V
Sugiyama, Fumihiro
Martin, Janice E
Tomarev, Stanislav I
Paigen, Beverly J
Smith, Richard S
John, Simon WM
Intraocular pressure in genetically distinct mice: an update and strain survey
title Intraocular pressure in genetically distinct mice: an update and strain survey
title_full Intraocular pressure in genetically distinct mice: an update and strain survey
title_fullStr Intraocular pressure in genetically distinct mice: an update and strain survey
title_full_unstemmed Intraocular pressure in genetically distinct mice: an update and strain survey
title_short Intraocular pressure in genetically distinct mice: an update and strain survey
title_sort intraocular pressure in genetically distinct mice: an update and strain survey
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC48141/
https://www.ncbi.nlm.nih.gov/pubmed/11532192
http://dx.doi.org/10.1186/1471-2156-2-12
work_keys_str_mv AT savinovaolgav intraocularpressureingeneticallydistinctmiceanupdateandstrainsurvey
AT sugiyamafumihiro intraocularpressureingeneticallydistinctmiceanupdateandstrainsurvey
AT martinjanicee intraocularpressureingeneticallydistinctmiceanupdateandstrainsurvey
AT tomarevstanislavi intraocularpressureingeneticallydistinctmiceanupdateandstrainsurvey
AT paigenbeverlyj intraocularpressureingeneticallydistinctmiceanupdateandstrainsurvey
AT smithrichards intraocularpressureingeneticallydistinctmiceanupdateandstrainsurvey
AT johnsimonwm intraocularpressureingeneticallydistinctmiceanupdateandstrainsurvey