Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients
BACKGROUND: The purpose of this study was to compare corneal power and horizontal corneal diameter (white-to-white [WTW] distance) readings obtained by the Orbscan II topographer and the iTrace aberrometer. METHODS: Keratometry readings in the flat (Kf) and steep (Ks) meridians and WTW distance were...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4815140/ https://www.ncbi.nlm.nih.gov/pubmed/27029933 http://dx.doi.org/10.1186/s12886-016-0210-8 |
_version_ | 1782424546432778240 |
---|---|
author | Chen, Yao Xia, Xiaobo |
author_facet | Chen, Yao Xia, Xiaobo |
author_sort | Chen, Yao |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to compare corneal power and horizontal corneal diameter (white-to-white [WTW] distance) readings obtained by the Orbscan II topographer and the iTrace aberrometer. METHODS: Keratometry readings in the flat (Kf) and steep (Ks) meridians and WTW distance were measured with the Orbscan II and iTrace systems in 100 myopic patients. Statistical evaluation was performed using the paired t test, Pearson correlation, and Bland-Altman analysis for comparison of measurement techniques. RESULTS: The mean keratometry values with the Orbscan II and iTrace were 43.16 ± 1.44 and 42.64 ± 1.43 diopter (D), respectively (P < 0.0001). The mean WTW distance measurements with the Orbscan II and iTrace were 11.57 ± 0.34 and 11.33 ± 0.36 mm, respectively (P < 0.0001). For the measurement of corneal power, the 95 % limits of agreement (LoA) between the Orbscan II and iTrace were − 0.21 to 1.21 D for the flat meridian and − 0.15 to 1.25 D for the steep meridian. For the measurement of WTW distance, the range of the 95 % LoA between the two devices was 0.47 mm. CONCLUSIONS: For some clinical applications, the keratometry and WTW distance measurements obtained by the Orbscan II topographer and the iTrace aberrometer differed greatly and therefore were not interchangeable. TRIAL REGISTRATION: Clinical trials number: ChiCTR-OCS-14005077 (August 2nd, 2014). |
format | Online Article Text |
id | pubmed-4815140 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-48151402016-04-01 Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients Chen, Yao Xia, Xiaobo BMC Ophthalmol Research Article BACKGROUND: The purpose of this study was to compare corneal power and horizontal corneal diameter (white-to-white [WTW] distance) readings obtained by the Orbscan II topographer and the iTrace aberrometer. METHODS: Keratometry readings in the flat (Kf) and steep (Ks) meridians and WTW distance were measured with the Orbscan II and iTrace systems in 100 myopic patients. Statistical evaluation was performed using the paired t test, Pearson correlation, and Bland-Altman analysis for comparison of measurement techniques. RESULTS: The mean keratometry values with the Orbscan II and iTrace were 43.16 ± 1.44 and 42.64 ± 1.43 diopter (D), respectively (P < 0.0001). The mean WTW distance measurements with the Orbscan II and iTrace were 11.57 ± 0.34 and 11.33 ± 0.36 mm, respectively (P < 0.0001). For the measurement of corneal power, the 95 % limits of agreement (LoA) between the Orbscan II and iTrace were − 0.21 to 1.21 D for the flat meridian and − 0.15 to 1.25 D for the steep meridian. For the measurement of WTW distance, the range of the 95 % LoA between the two devices was 0.47 mm. CONCLUSIONS: For some clinical applications, the keratometry and WTW distance measurements obtained by the Orbscan II topographer and the iTrace aberrometer differed greatly and therefore were not interchangeable. TRIAL REGISTRATION: Clinical trials number: ChiCTR-OCS-14005077 (August 2nd, 2014). BioMed Central 2016-03-31 /pmc/articles/PMC4815140/ /pubmed/27029933 http://dx.doi.org/10.1186/s12886-016-0210-8 Text en © Chen and Xia. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Chen, Yao Xia, Xiaobo Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients |
title | Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients |
title_full | Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients |
title_fullStr | Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients |
title_full_unstemmed | Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients |
title_short | Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients |
title_sort | comparison of the orbscan ii topographer and the itrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4815140/ https://www.ncbi.nlm.nih.gov/pubmed/27029933 http://dx.doi.org/10.1186/s12886-016-0210-8 |
work_keys_str_mv | AT chenyao comparisonoftheorbscaniitopographerandtheitraceaberrometerforthemeasurementsofkeratometryandcornealdiameterinmyopicpatients AT xiaxiaobo comparisonoftheorbscaniitopographerandtheitraceaberrometerforthemeasurementsofkeratometryandcornealdiameterinmyopicpatients |