Cargando…

Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals

OBJECTIVE: In the era of bare metal stents (BMSs), alloys have been considered to be better materials for stent design than stainless steel. In the era of biodegradable polymer drug-eluting stents (BP-DESs), the safety and efficacy of BP-DESs with different metal platforms (stainless steel or alloys...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Yun-Feng, Jiang, Long, Zhang, Ming-Duo, Li, Xin-He, Nie, Mao-Xiao, Feng, Ting-Ting, Zhao, Xin, Wang, Lu-Ya, Zhao, Quan-Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4816558/
https://www.ncbi.nlm.nih.gov/pubmed/27032086
http://dx.doi.org/10.1371/journal.pone.0151259
_version_ 1782424738263465984
author Yan, Yun-Feng
Jiang, Long
Zhang, Ming-Duo
Li, Xin-He
Nie, Mao-Xiao
Feng, Ting-Ting
Zhao, Xin
Wang, Lu-Ya
Zhao, Quan-Ming
author_facet Yan, Yun-Feng
Jiang, Long
Zhang, Ming-Duo
Li, Xin-He
Nie, Mao-Xiao
Feng, Ting-Ting
Zhao, Xin
Wang, Lu-Ya
Zhao, Quan-Ming
author_sort Yan, Yun-Feng
collection PubMed
description OBJECTIVE: In the era of bare metal stents (BMSs), alloys have been considered to be better materials for stent design than stainless steel. In the era of biodegradable polymer drug-eluting stents (BP-DESs), the safety and efficacy of BP-DESs with different metal platforms (stainless steel or alloys) have not yet been reported, although their polymers are eventually absorbed, and only the metal platforms remain in the body. This study sought to determine the clinical safety and efficacy of BP-DESs with different platforms compared with other stents (other DESs and BMSs). METHODS: PubMed, Embase and Clinical Trials.gov were searched for randomized controlled trials (RCTs) that compared BP-DESs with other stents. After performing pooled analysis of BP-DESs and other stents, we performed a subgroup analysis using two classification methods: stent platform and follow-up time. The study characteristics, patient characteristics and clinical outcomes were abstracted. RESULTS: Forty RCTs (49 studies) comprising 34,850 patients were included. Biodegradable polymer stainless drug-eluting stents (BP-stainless DESs) were superior to the other stents [mainly stainless drug-eluting stents (DESs)] in terms of pooled definite/probable stent thrombosis (ST) (OR [95% CI] = 0.76[0.61–0.95], p = 0.02), long-term definite/probable ST (OR [95% CI] = 0.73[0.57–0.94], p = 0.01), very late definite/probable ST (OR [95% CI] = 0.56[0.33–0.93], p = 0.03) and long-term definite ST. BP-stainless DESs had lower rates of pooled, mid-term and long-term target vessel revascularization (TVR) and target lesion revascularization (TLR) than the other stainless DESs and BMSs. Furthermore, BP-stainless DESs were associated with lower rates of long-term death than other stainless DESs and lower rates of mid-term myocardial infarction than BMSs. However, only the mid-term and long-term TVR rates were superior in BP-alloy DESs compared with the other stents. CONCLUSION: Our results indirectly suggest that BP-stainless DESs may offer more benefits than BP-alloy DESs in the era of BP-DESs. Further well-designed RCTs comparing BP-stainless with BP-alloy DESs are needed to confirm which platform is better.
format Online
Article
Text
id pubmed-4816558
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48165582016-04-14 Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals Yan, Yun-Feng Jiang, Long Zhang, Ming-Duo Li, Xin-He Nie, Mao-Xiao Feng, Ting-Ting Zhao, Xin Wang, Lu-Ya Zhao, Quan-Ming PLoS One Research Article OBJECTIVE: In the era of bare metal stents (BMSs), alloys have been considered to be better materials for stent design than stainless steel. In the era of biodegradable polymer drug-eluting stents (BP-DESs), the safety and efficacy of BP-DESs with different metal platforms (stainless steel or alloys) have not yet been reported, although their polymers are eventually absorbed, and only the metal platforms remain in the body. This study sought to determine the clinical safety and efficacy of BP-DESs with different platforms compared with other stents (other DESs and BMSs). METHODS: PubMed, Embase and Clinical Trials.gov were searched for randomized controlled trials (RCTs) that compared BP-DESs with other stents. After performing pooled analysis of BP-DESs and other stents, we performed a subgroup analysis using two classification methods: stent platform and follow-up time. The study characteristics, patient characteristics and clinical outcomes were abstracted. RESULTS: Forty RCTs (49 studies) comprising 34,850 patients were included. Biodegradable polymer stainless drug-eluting stents (BP-stainless DESs) were superior to the other stents [mainly stainless drug-eluting stents (DESs)] in terms of pooled definite/probable stent thrombosis (ST) (OR [95% CI] = 0.76[0.61–0.95], p = 0.02), long-term definite/probable ST (OR [95% CI] = 0.73[0.57–0.94], p = 0.01), very late definite/probable ST (OR [95% CI] = 0.56[0.33–0.93], p = 0.03) and long-term definite ST. BP-stainless DESs had lower rates of pooled, mid-term and long-term target vessel revascularization (TVR) and target lesion revascularization (TLR) than the other stainless DESs and BMSs. Furthermore, BP-stainless DESs were associated with lower rates of long-term death than other stainless DESs and lower rates of mid-term myocardial infarction than BMSs. However, only the mid-term and long-term TVR rates were superior in BP-alloy DESs compared with the other stents. CONCLUSION: Our results indirectly suggest that BP-stainless DESs may offer more benefits than BP-alloy DESs in the era of BP-DESs. Further well-designed RCTs comparing BP-stainless with BP-alloy DESs are needed to confirm which platform is better. Public Library of Science 2016-03-31 /pmc/articles/PMC4816558/ /pubmed/27032086 http://dx.doi.org/10.1371/journal.pone.0151259 Text en © 2016 Yan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Yan, Yun-Feng
Jiang, Long
Zhang, Ming-Duo
Li, Xin-He
Nie, Mao-Xiao
Feng, Ting-Ting
Zhao, Xin
Wang, Lu-Ya
Zhao, Quan-Ming
Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals
title Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals
title_full Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals
title_fullStr Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals
title_full_unstemmed Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals
title_short Can Platforms Affect the Safety and Efficacy of Drug-Eluting Stents in the Era of Biodegradable Polymers?: A Meta-Analysis of 34,850 Randomized Individuals
title_sort can platforms affect the safety and efficacy of drug-eluting stents in the era of biodegradable polymers?: a meta-analysis of 34,850 randomized individuals
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4816558/
https://www.ncbi.nlm.nih.gov/pubmed/27032086
http://dx.doi.org/10.1371/journal.pone.0151259
work_keys_str_mv AT yanyunfeng canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT jianglong canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT zhangmingduo canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT lixinhe canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT niemaoxiao canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT fengtingting canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT zhaoxin canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT wangluya canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals
AT zhaoquanming canplatformsaffectthesafetyandefficacyofdrugelutingstentsintheeraofbiodegradablepolymersametaanalysisof34850randomizedindividuals