Cargando…

A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography

PURPOSE: Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Hee Jin, Lee, Sungeun, Lee, Eun Joo, Song, In Ja, Kang, Byung-Cheol, Lee, Jae-Seo, Lim, Hoi-Jeong, Yoon, Suk-Ja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4816769/
https://www.ncbi.nlm.nih.gov/pubmed/27051637
http://dx.doi.org/10.5624/isd.2016.46.1.33
_version_ 1782424763649490944
author Lee, Hee Jin
Lee, Sungeun
Lee, Eun Joo
Song, In Ja
Kang, Byung-Cheol
Lee, Jae-Seo
Lim, Hoi-Jeong
Yoon, Suk-Ja
author_facet Lee, Hee Jin
Lee, Sungeun
Lee, Eun Joo
Song, In Ja
Kang, Byung-Cheol
Lee, Jae-Seo
Lim, Hoi-Jeong
Yoon, Suk-Ja
author_sort Lee, Hee Jin
collection PubMed
description PURPOSE: Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. MATERIALS AND METHODS: PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of 22.1±3.3 years) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates (x(1) and x(2)) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. RESULTS: A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (Δx=2.45±2.03 mm, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). CONCLUSION: The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients.
format Online
Article
Text
id pubmed-4816769
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-48167692016-04-05 A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography Lee, Hee Jin Lee, Sungeun Lee, Eun Joo Song, In Ja Kang, Byung-Cheol Lee, Jae-Seo Lim, Hoi-Jeong Yoon, Suk-Ja Imaging Sci Dent Original Article PURPOSE: Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. MATERIALS AND METHODS: PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of 22.1±3.3 years) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates (x(1) and x(2)) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. RESULTS: A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (Δx=2.45±2.03 mm, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). CONCLUSION: The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients. Korean Academy of Oral and Maxillofacial Radiology 2016-03 2016-03-24 /pmc/articles/PMC4816769/ /pubmed/27051637 http://dx.doi.org/10.5624/isd.2016.46.1.33 Text en Copyright © 2016 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Hee Jin
Lee, Sungeun
Lee, Eun Joo
Song, In Ja
Kang, Byung-Cheol
Lee, Jae-Seo
Lim, Hoi-Jeong
Yoon, Suk-Ja
A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography
title A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography
title_full A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography
title_fullStr A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography
title_full_unstemmed A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography
title_short A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography
title_sort comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4816769/
https://www.ncbi.nlm.nih.gov/pubmed/27051637
http://dx.doi.org/10.5624/isd.2016.46.1.33
work_keys_str_mv AT leeheejin acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT leesungeun acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT leeeunjoo acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT songinja acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT kangbyungcheol acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT leejaeseo acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT limhoijeong acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT yoonsukja acomparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT leeheejin comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT leesungeun comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT leeeunjoo comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT songinja comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT kangbyungcheol comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT leejaeseo comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT limhoijeong comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography
AT yoonsukja comparativestudyofthedeviationofthementononposteroanteriorcephalogramsandthreedimensionalcomputedtomography