Cargando…
Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer
BACKGROUND: Although sentinel lymph node biopsy (SLNB) can accurately predict the status of axillary lymph node (ALN) metastasis, the high false-negative rate (FNR) of SLNB is still the main obstacle for the treatment of patients who receive SLNB instead of ALN dissection (ALND). The purpose of this...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4820923/ https://www.ncbi.nlm.nih.gov/pubmed/27044285 http://dx.doi.org/10.1186/s40880-016-0099-x |
_version_ | 1782425496101847040 |
---|---|
author | Han, Chao Yang, Ben Zuo, Wen-Shu Liu, Yan-Song Zheng, Gang Yang, Li Zheng, Mei-Zhu |
author_facet | Han, Chao Yang, Ben Zuo, Wen-Shu Liu, Yan-Song Zheng, Gang Yang, Li Zheng, Mei-Zhu |
author_sort | Han, Chao |
collection | PubMed |
description | BACKGROUND: Although sentinel lymph node biopsy (SLNB) can accurately predict the status of axillary lymph node (ALN) metastasis, the high false-negative rate (FNR) of SLNB is still the main obstacle for the treatment of patients who receive SLNB instead of ALN dissection (ALND). The purpose of this study was to evaluate the clinical significance of SLNB combined with peripheral lymph node (PLN) sampling for reducing the FNR for breast cancer and to discuss the effect of “skip metastasis” on the FNR of SLNB. METHODS: At Shandong Cancer Hospital Affiliated to Shandong University between March 1, 2012 and June 30, 2015, the sentinel lymph nodes (SLNs) of 596 patients with breast cancer were examined using radiocolloids with blue dye tracer. First, the SLNs were removed; then, the area surrounding the original SLNs was selected, and the visible lymph nodes in a field of 3–5 cm in diameter around the center (i.e., PLNs) were removed, avoiding damage to the structure of the breast. Finally, ALND was performed. The SLNs, PLNs, and remaining ALNs underwent pathologic examination, and the relationship between them was analyzed. RESULTS: The identification rate of SLNs in the 596 patients was 95.1% (567/596); the metastasis rate of ALNs was 33.7% (191/567); the FNR of pure SLNB was 9.9% (19/191); and after the SLNs and PLNs were eliminated, the FNR was 4.2% (8/191), which was significantly decreased compared with the FNR before removal of PLNs (P = 0.028). According to the detected number (N) of SLNs, the patients were divided into four groups of N = 1, 2, 3, and ≥4; the FNR in these groups was 19.6, 9.8, 7.3, and 2.3%, respectively. For the patients with ≤2 or ≤3 detected SLNs, the FNR after removal of PLNs was significantly decreased compared with that before removal of PLNs (N ≤ 2: 14.0% vs. 4.7%, P = 0.019; N ≤ 3: 12.2% vs. 4.7%, P = 0.021), whereas for patients with ≥4 detected SLNs, the decrease in FNR was not statistically significant (P = 1.000). In the entire cohorts, the “skip metastasis” rate was 2.5% (15/596); the FNR caused by “skip metastasis” was 2.1% (4/191). CONCLUSIONS: The FNR of SLNB was associated with the number of SLNs. For patients with ≤3 detected SLNs, PLN sampling can reduce the FNR of SLNB to an acceptable level of less than 5%. Because of the existence of the “skip metastasis” and distinct metastasis patterns, the FNR of SLNB cannot be completely eliminated. |
format | Online Article Text |
id | pubmed-4820923 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-48209232016-04-06 Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer Han, Chao Yang, Ben Zuo, Wen-Shu Liu, Yan-Song Zheng, Gang Yang, Li Zheng, Mei-Zhu Chin J Cancer Original Article BACKGROUND: Although sentinel lymph node biopsy (SLNB) can accurately predict the status of axillary lymph node (ALN) metastasis, the high false-negative rate (FNR) of SLNB is still the main obstacle for the treatment of patients who receive SLNB instead of ALN dissection (ALND). The purpose of this study was to evaluate the clinical significance of SLNB combined with peripheral lymph node (PLN) sampling for reducing the FNR for breast cancer and to discuss the effect of “skip metastasis” on the FNR of SLNB. METHODS: At Shandong Cancer Hospital Affiliated to Shandong University between March 1, 2012 and June 30, 2015, the sentinel lymph nodes (SLNs) of 596 patients with breast cancer were examined using radiocolloids with blue dye tracer. First, the SLNs were removed; then, the area surrounding the original SLNs was selected, and the visible lymph nodes in a field of 3–5 cm in diameter around the center (i.e., PLNs) were removed, avoiding damage to the structure of the breast. Finally, ALND was performed. The SLNs, PLNs, and remaining ALNs underwent pathologic examination, and the relationship between them was analyzed. RESULTS: The identification rate of SLNs in the 596 patients was 95.1% (567/596); the metastasis rate of ALNs was 33.7% (191/567); the FNR of pure SLNB was 9.9% (19/191); and after the SLNs and PLNs were eliminated, the FNR was 4.2% (8/191), which was significantly decreased compared with the FNR before removal of PLNs (P = 0.028). According to the detected number (N) of SLNs, the patients were divided into four groups of N = 1, 2, 3, and ≥4; the FNR in these groups was 19.6, 9.8, 7.3, and 2.3%, respectively. For the patients with ≤2 or ≤3 detected SLNs, the FNR after removal of PLNs was significantly decreased compared with that before removal of PLNs (N ≤ 2: 14.0% vs. 4.7%, P = 0.019; N ≤ 3: 12.2% vs. 4.7%, P = 0.021), whereas for patients with ≥4 detected SLNs, the decrease in FNR was not statistically significant (P = 1.000). In the entire cohorts, the “skip metastasis” rate was 2.5% (15/596); the FNR caused by “skip metastasis” was 2.1% (4/191). CONCLUSIONS: The FNR of SLNB was associated with the number of SLNs. For patients with ≤3 detected SLNs, PLN sampling can reduce the FNR of SLNB to an acceptable level of less than 5%. Because of the existence of the “skip metastasis” and distinct metastasis patterns, the FNR of SLNB cannot be completely eliminated. BioMed Central 2016-04-04 /pmc/articles/PMC4820923/ /pubmed/27044285 http://dx.doi.org/10.1186/s40880-016-0099-x Text en © Han et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Original Article Han, Chao Yang, Ben Zuo, Wen-Shu Liu, Yan-Song Zheng, Gang Yang, Li Zheng, Mei-Zhu Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer |
title | Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer |
title_full | Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer |
title_fullStr | Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer |
title_full_unstemmed | Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer |
title_short | Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer |
title_sort | prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4820923/ https://www.ncbi.nlm.nih.gov/pubmed/27044285 http://dx.doi.org/10.1186/s40880-016-0099-x |
work_keys_str_mv | AT hanchao prospectivestudyfoundthatperipherallymphnodesamplingreducedthefalsenegativerateofsentinellymphnodebiopsyforbreastcancer AT yangben prospectivestudyfoundthatperipherallymphnodesamplingreducedthefalsenegativerateofsentinellymphnodebiopsyforbreastcancer AT zuowenshu prospectivestudyfoundthatperipherallymphnodesamplingreducedthefalsenegativerateofsentinellymphnodebiopsyforbreastcancer AT liuyansong prospectivestudyfoundthatperipherallymphnodesamplingreducedthefalsenegativerateofsentinellymphnodebiopsyforbreastcancer AT zhenggang prospectivestudyfoundthatperipherallymphnodesamplingreducedthefalsenegativerateofsentinellymphnodebiopsyforbreastcancer AT yangli prospectivestudyfoundthatperipherallymphnodesamplingreducedthefalsenegativerateofsentinellymphnodebiopsyforbreastcancer AT zhengmeizhu prospectivestudyfoundthatperipherallymphnodesamplingreducedthefalsenegativerateofsentinellymphnodebiopsyforbreastcancer |