Load and failure behavior of human muscle samples in the context of proximal femur replacement

BACKGROUND: To ensure adequate function after orthopedic tumor reconstruction, it is important to reattach the remaining soft tissue to the implant. This study aimed at obtaining mechanical properties of textile muscle-implant and muscle-bone connections in a preliminary test. METHODS: Two groups of...