Cargando…
A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
BACKGROUND: Neck flexion by head elevation using an 8 to 10 cm thick pillow and head extension has been suggested to align the laryngeal, pharyngeal and oral axis and facilitate tracheal intubation. Presently, the laryngeal view and discomfort for tracheal intubation were evaluated according to two...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Anesthesiologists
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823408/ https://www.ncbi.nlm.nih.gov/pubmed/27066204 http://dx.doi.org/10.4097/kjae.2016.69.2.138 |
_version_ | 1782425909671755776 |
---|---|
author | Hong, Hyo Ju Yun, Mijung Kim, Sung Hoon Hwang, Jung Won Lee, Hyung Chul |
author_facet | Hong, Hyo Ju Yun, Mijung Kim, Sung Hoon Hwang, Jung Won Lee, Hyung Chul |
author_sort | Hong, Hyo Ju |
collection | PubMed |
description | BACKGROUND: Neck flexion by head elevation using an 8 to 10 cm thick pillow and head extension has been suggested to align the laryngeal, pharyngeal and oral axis and facilitate tracheal intubation. Presently, the laryngeal view and discomfort for tracheal intubation were evaluated according to two different degrees of head elevation in adult patients. METHODS: This prospective randomized, controlled study included 50 adult patients aged 18 to 90 years. After induction of anesthesia, the Cormack Lehane grade was evaluated in 25 patients using a direct laryngoscope while the patient's head was elevated with a 4 cm pillow (4 cm group) and then an 8 cm pillow (8 cm group). In the other 25 patients, the grades were evaluated in the opposite sequence and tracheal intubation was performed. The success rate and anesthesiologist's discomfort score for tracheal intubation, and laryngeal, pharyngeal and oral axes were assessed. RESULTS: There were no differences in the laryngeal view and success rate for tracheal intubation between the two groups. The discomfort score during tracheal intubation was higher in the 8 cm group when the patient's head was elevated 4 cm first and then 8 cm. The alignment of laryngeal, pharyngeal and oral axes were not different between the two degrees of head elevation. CONCLUSIONS: A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased the anesthesiologist discomfort, compared to a pillow of 4 cm height, during tracheal intubation in adult patients. |
format | Online Article Text |
id | pubmed-4823408 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Anesthesiologists |
record_format | MEDLINE/PubMed |
spelling | pubmed-48234082016-04-10 A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients Hong, Hyo Ju Yun, Mijung Kim, Sung Hoon Hwang, Jung Won Lee, Hyung Chul Korean J Anesthesiol Clinical Research Article BACKGROUND: Neck flexion by head elevation using an 8 to 10 cm thick pillow and head extension has been suggested to align the laryngeal, pharyngeal and oral axis and facilitate tracheal intubation. Presently, the laryngeal view and discomfort for tracheal intubation were evaluated according to two different degrees of head elevation in adult patients. METHODS: This prospective randomized, controlled study included 50 adult patients aged 18 to 90 years. After induction of anesthesia, the Cormack Lehane grade was evaluated in 25 patients using a direct laryngoscope while the patient's head was elevated with a 4 cm pillow (4 cm group) and then an 8 cm pillow (8 cm group). In the other 25 patients, the grades were evaluated in the opposite sequence and tracheal intubation was performed. The success rate and anesthesiologist's discomfort score for tracheal intubation, and laryngeal, pharyngeal and oral axes were assessed. RESULTS: There were no differences in the laryngeal view and success rate for tracheal intubation between the two groups. The discomfort score during tracheal intubation was higher in the 8 cm group when the patient's head was elevated 4 cm first and then 8 cm. The alignment of laryngeal, pharyngeal and oral axes were not different between the two degrees of head elevation. CONCLUSIONS: A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased the anesthesiologist discomfort, compared to a pillow of 4 cm height, during tracheal intubation in adult patients. The Korean Society of Anesthesiologists 2016-04 2016-03-30 /pmc/articles/PMC4823408/ /pubmed/27066204 http://dx.doi.org/10.4097/kjae.2016.69.2.138 Text en Copyright © the Korean Society of Anesthesiologists, 2016 http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Research Article Hong, Hyo Ju Yun, Mijung Kim, Sung Hoon Hwang, Jung Won Lee, Hyung Chul A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients |
title | A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients |
title_full | A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients |
title_fullStr | A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients |
title_full_unstemmed | A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients |
title_short | A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients |
title_sort | pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients |
topic | Clinical Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823408/ https://www.ncbi.nlm.nih.gov/pubmed/27066204 http://dx.doi.org/10.4097/kjae.2016.69.2.138 |
work_keys_str_mv | AT honghyoju apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT yunmijung apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT kimsunghoon apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT hwangjungwon apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT leehyungchul apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT honghyoju pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT yunmijung pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT kimsunghoon pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT hwangjungwon pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients AT leehyungchul pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients |