Cargando…

A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients

BACKGROUND: Neck flexion by head elevation using an 8 to 10 cm thick pillow and head extension has been suggested to align the laryngeal, pharyngeal and oral axis and facilitate tracheal intubation. Presently, the laryngeal view and discomfort for tracheal intubation were evaluated according to two...

Descripción completa

Detalles Bibliográficos
Autores principales: Hong, Hyo Ju, Yun, Mijung, Kim, Sung Hoon, Hwang, Jung Won, Lee, Hyung Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Anesthesiologists 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823408/
https://www.ncbi.nlm.nih.gov/pubmed/27066204
http://dx.doi.org/10.4097/kjae.2016.69.2.138
_version_ 1782425909671755776
author Hong, Hyo Ju
Yun, Mijung
Kim, Sung Hoon
Hwang, Jung Won
Lee, Hyung Chul
author_facet Hong, Hyo Ju
Yun, Mijung
Kim, Sung Hoon
Hwang, Jung Won
Lee, Hyung Chul
author_sort Hong, Hyo Ju
collection PubMed
description BACKGROUND: Neck flexion by head elevation using an 8 to 10 cm thick pillow and head extension has been suggested to align the laryngeal, pharyngeal and oral axis and facilitate tracheal intubation. Presently, the laryngeal view and discomfort for tracheal intubation were evaluated according to two different degrees of head elevation in adult patients. METHODS: This prospective randomized, controlled study included 50 adult patients aged 18 to 90 years. After induction of anesthesia, the Cormack Lehane grade was evaluated in 25 patients using a direct laryngoscope while the patient's head was elevated with a 4 cm pillow (4 cm group) and then an 8 cm pillow (8 cm group). In the other 25 patients, the grades were evaluated in the opposite sequence and tracheal intubation was performed. The success rate and anesthesiologist's discomfort score for tracheal intubation, and laryngeal, pharyngeal and oral axes were assessed. RESULTS: There were no differences in the laryngeal view and success rate for tracheal intubation between the two groups. The discomfort score during tracheal intubation was higher in the 8 cm group when the patient's head was elevated 4 cm first and then 8 cm. The alignment of laryngeal, pharyngeal and oral axes were not different between the two degrees of head elevation. CONCLUSIONS: A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased the anesthesiologist discomfort, compared to a pillow of 4 cm height, during tracheal intubation in adult patients.
format Online
Article
Text
id pubmed-4823408
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Society of Anesthesiologists
record_format MEDLINE/PubMed
spelling pubmed-48234082016-04-10 A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients Hong, Hyo Ju Yun, Mijung Kim, Sung Hoon Hwang, Jung Won Lee, Hyung Chul Korean J Anesthesiol Clinical Research Article BACKGROUND: Neck flexion by head elevation using an 8 to 10 cm thick pillow and head extension has been suggested to align the laryngeal, pharyngeal and oral axis and facilitate tracheal intubation. Presently, the laryngeal view and discomfort for tracheal intubation were evaluated according to two different degrees of head elevation in adult patients. METHODS: This prospective randomized, controlled study included 50 adult patients aged 18 to 90 years. After induction of anesthesia, the Cormack Lehane grade was evaluated in 25 patients using a direct laryngoscope while the patient's head was elevated with a 4 cm pillow (4 cm group) and then an 8 cm pillow (8 cm group). In the other 25 patients, the grades were evaluated in the opposite sequence and tracheal intubation was performed. The success rate and anesthesiologist's discomfort score for tracheal intubation, and laryngeal, pharyngeal and oral axes were assessed. RESULTS: There were no differences in the laryngeal view and success rate for tracheal intubation between the two groups. The discomfort score during tracheal intubation was higher in the 8 cm group when the patient's head was elevated 4 cm first and then 8 cm. The alignment of laryngeal, pharyngeal and oral axes were not different between the two degrees of head elevation. CONCLUSIONS: A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased the anesthesiologist discomfort, compared to a pillow of 4 cm height, during tracheal intubation in adult patients. The Korean Society of Anesthesiologists 2016-04 2016-03-30 /pmc/articles/PMC4823408/ /pubmed/27066204 http://dx.doi.org/10.4097/kjae.2016.69.2.138 Text en Copyright © the Korean Society of Anesthesiologists, 2016 http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Research Article
Hong, Hyo Ju
Yun, Mijung
Kim, Sung Hoon
Hwang, Jung Won
Lee, Hyung Chul
A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
title A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
title_full A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
title_fullStr A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
title_full_unstemmed A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
title_short A pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
title_sort pillow of 8 cm height did not improve laryngeal view and alignment of airway axes but increased anesthesiologist discomfort compared to a pillow of 4 cm height during tracheal intubation in adult patients
topic Clinical Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823408/
https://www.ncbi.nlm.nih.gov/pubmed/27066204
http://dx.doi.org/10.4097/kjae.2016.69.2.138
work_keys_str_mv AT honghyoju apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT yunmijung apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT kimsunghoon apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT hwangjungwon apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT leehyungchul apillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT honghyoju pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT yunmijung pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT kimsunghoon pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT hwangjungwon pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients
AT leehyungchul pillowof8cmheightdidnotimprovelaryngealviewandalignmentofairwayaxesbutincreasedanesthesiologistdiscomfortcomparedtoapillowof4cmheightduringtrachealintubationinadultpatients