Cargando…

Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases

Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS) can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal...

Descripción completa

Detalles Bibliográficos
Autores principales: Bondue, Benjamin, Schlossmacher, Pascal, Knoop, Christiane, Etienne, Isabelle, Luce, Sylvie, Sokolow, Youri, Leduc, Dimitri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823484/
https://www.ncbi.nlm.nih.gov/pubmed/27110422
http://dx.doi.org/10.1155/2016/6742349
_version_ 1782425927007862784
author Bondue, Benjamin
Schlossmacher, Pascal
Knoop, Christiane
Etienne, Isabelle
Luce, Sylvie
Sokolow, Youri
Leduc, Dimitri
author_facet Bondue, Benjamin
Schlossmacher, Pascal
Knoop, Christiane
Etienne, Isabelle
Luce, Sylvie
Sokolow, Youri
Leduc, Dimitri
author_sort Bondue, Benjamin
collection PubMed
description Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS) can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal bronchial restenosis treated by insertion of an additional stent inside the lumen of the previously inserted stent using the stent-in-stent (SIS) technique. The indications for the initial stent were malignancy in Patient 1 and posttransplant bronchial stenosis in Patient 2. Restenosis occurred at the proximal end of the stent within months in both cases. Stent removal and insertion of a new stent were considered, but this option was discarded because of an excessive risk of bronchial perforation and preference towards an alternative approach. In both cases, a second customized SEMS was placed using the SIS technique after ablation of the proximal end stenosis of the stent by argon plasma coagulation and/or dilation with a balloon. Recanalization of the bronchus was achieved in both cases without complications. The SIS technique is a valuable alternative to removal of SEMS in case of proximal bronchial restenosis.
format Online
Article
Text
id pubmed-4823484
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-48234842016-04-24 Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases Bondue, Benjamin Schlossmacher, Pascal Knoop, Christiane Etienne, Isabelle Luce, Sylvie Sokolow, Youri Leduc, Dimitri Case Rep Pulmonol Case Report Endoscopic treatment of a bronchial restenosis previously treated by insertion of a partially covered self-expandable metallic stent (SEMS) can be difficult. Classically, after recanalization of the bronchus, the stent is removed and replaced by a more adapted one. We report on two cases of proximal bronchial restenosis treated by insertion of an additional stent inside the lumen of the previously inserted stent using the stent-in-stent (SIS) technique. The indications for the initial stent were malignancy in Patient 1 and posttransplant bronchial stenosis in Patient 2. Restenosis occurred at the proximal end of the stent within months in both cases. Stent removal and insertion of a new stent were considered, but this option was discarded because of an excessive risk of bronchial perforation and preference towards an alternative approach. In both cases, a second customized SEMS was placed using the SIS technique after ablation of the proximal end stenosis of the stent by argon plasma coagulation and/or dilation with a balloon. Recanalization of the bronchus was achieved in both cases without complications. The SIS technique is a valuable alternative to removal of SEMS in case of proximal bronchial restenosis. Hindawi Publishing Corporation 2016 2016-03-24 /pmc/articles/PMC4823484/ /pubmed/27110422 http://dx.doi.org/10.1155/2016/6742349 Text en Copyright © 2016 Benjamin Bondue et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Bondue, Benjamin
Schlossmacher, Pascal
Knoop, Christiane
Etienne, Isabelle
Luce, Sylvie
Sokolow, Youri
Leduc, Dimitri
Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases
title Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases
title_full Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases
title_fullStr Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases
title_full_unstemmed Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases
title_short Stent-in-Stent Technique for the Treatment of Proximal Bronchial Restenosis after Insertion of Metallic Stents: A Report of Two Cases
title_sort stent-in-stent technique for the treatment of proximal bronchial restenosis after insertion of metallic stents: a report of two cases
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823484/
https://www.ncbi.nlm.nih.gov/pubmed/27110422
http://dx.doi.org/10.1155/2016/6742349
work_keys_str_mv AT bonduebenjamin stentinstenttechniqueforthetreatmentofproximalbronchialrestenosisafterinsertionofmetallicstentsareportoftwocases
AT schlossmacherpascal stentinstenttechniqueforthetreatmentofproximalbronchialrestenosisafterinsertionofmetallicstentsareportoftwocases
AT knoopchristiane stentinstenttechniqueforthetreatmentofproximalbronchialrestenosisafterinsertionofmetallicstentsareportoftwocases
AT etienneisabelle stentinstenttechniqueforthetreatmentofproximalbronchialrestenosisafterinsertionofmetallicstentsareportoftwocases
AT lucesylvie stentinstenttechniqueforthetreatmentofproximalbronchialrestenosisafterinsertionofmetallicstentsareportoftwocases
AT sokolowyouri stentinstenttechniqueforthetreatmentofproximalbronchialrestenosisafterinsertionofmetallicstentsareportoftwocases
AT leducdimitri stentinstenttechniqueforthetreatmentofproximalbronchialrestenosisafterinsertionofmetallicstentsareportoftwocases