Cargando…

Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation

BACKGROUND: Although alteration of the amplitude and morphology of bipolar electrograms is used widely as a guide of the ablation effect, there is little information concerning unipolar electrograms. The amplitude and morphology of filtered bipolar (BP) and filtered unipolar (UP) electrograms were c...

Descripción completa

Detalles Bibliográficos
Autores principales: Kogawa, Rikitake, Watanabe, Ichiro, Okumura, Yasuo, Mano, Hiroaki, Sonoda, Kazumasa, Nagashima, Koichi, Sasaki, Naoko, Ohkubo, Kimie, Takahashi, Keiko, Iso, Kazuki, Kurokawa, Sayaka, Nakai, Toshiko, Hirayama, Atsushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823572/
https://www.ncbi.nlm.nih.gov/pubmed/27092191
http://dx.doi.org/10.1016/j.joa.2015.10.001
_version_ 1782425937844895744
author Kogawa, Rikitake
Watanabe, Ichiro
Okumura, Yasuo
Mano, Hiroaki
Sonoda, Kazumasa
Nagashima, Koichi
Sasaki, Naoko
Ohkubo, Kimie
Takahashi, Keiko
Iso, Kazuki
Kurokawa, Sayaka
Nakai, Toshiko
Hirayama, Atsushi
author_facet Kogawa, Rikitake
Watanabe, Ichiro
Okumura, Yasuo
Mano, Hiroaki
Sonoda, Kazumasa
Nagashima, Koichi
Sasaki, Naoko
Ohkubo, Kimie
Takahashi, Keiko
Iso, Kazuki
Kurokawa, Sayaka
Nakai, Toshiko
Hirayama, Atsushi
author_sort Kogawa, Rikitake
collection PubMed
description BACKGROUND: Although alteration of the amplitude and morphology of bipolar electrograms is used widely as a guide of the ablation effect, there is little information concerning unipolar electrograms. The amplitude and morphology of filtered bipolar (BP) and filtered unipolar (UP) electrograms were compared during pulmonary vein isolation in patients with atrial fibrillation. METHODS: BP (30–250 Hz) and UP (30–100 Hz) signals from the ablation catheter were recorded before and after each ablation point at the pulmonary vein antrum in 6 patients with atrial fibrillation. RESULTS: In the electrogram group with low-voltage amplitude in BP electrograms before ablation (<0.5 mV), the reduction in amplitude after ablation was significantly greater in the UP than in the BP electrograms, whereas the reduction was similar between the two recording methods in the electrogram group with high-voltage amplitude in BP electrograms (≥0.5 mV). Furthermore, the S wave in the UP electrograms disappeared at the sites of no pace capture after ablation, whereas no characteristic morphologic changes were observed in the BP electrograms. CONCLUSION: Filtered UP electrograms may be useful in assessing the effectiveness of lesion formation.
format Online
Article
Text
id pubmed-4823572
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-48235722016-04-18 Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation Kogawa, Rikitake Watanabe, Ichiro Okumura, Yasuo Mano, Hiroaki Sonoda, Kazumasa Nagashima, Koichi Sasaki, Naoko Ohkubo, Kimie Takahashi, Keiko Iso, Kazuki Kurokawa, Sayaka Nakai, Toshiko Hirayama, Atsushi J Arrhythm Original Article BACKGROUND: Although alteration of the amplitude and morphology of bipolar electrograms is used widely as a guide of the ablation effect, there is little information concerning unipolar electrograms. The amplitude and morphology of filtered bipolar (BP) and filtered unipolar (UP) electrograms were compared during pulmonary vein isolation in patients with atrial fibrillation. METHODS: BP (30–250 Hz) and UP (30–100 Hz) signals from the ablation catheter were recorded before and after each ablation point at the pulmonary vein antrum in 6 patients with atrial fibrillation. RESULTS: In the electrogram group with low-voltage amplitude in BP electrograms before ablation (<0.5 mV), the reduction in amplitude after ablation was significantly greater in the UP than in the BP electrograms, whereas the reduction was similar between the two recording methods in the electrogram group with high-voltage amplitude in BP electrograms (≥0.5 mV). Furthermore, the S wave in the UP electrograms disappeared at the sites of no pace capture after ablation, whereas no characteristic morphologic changes were observed in the BP electrograms. CONCLUSION: Filtered UP electrograms may be useful in assessing the effectiveness of lesion formation. Elsevier 2016-04 2015-11-27 /pmc/articles/PMC4823572/ /pubmed/27092191 http://dx.doi.org/10.1016/j.joa.2015.10.001 Text en © 2015 Japanese Heart Rhythm Society. Published by Elsevier B.V. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Kogawa, Rikitake
Watanabe, Ichiro
Okumura, Yasuo
Mano, Hiroaki
Sonoda, Kazumasa
Nagashima, Koichi
Sasaki, Naoko
Ohkubo, Kimie
Takahashi, Keiko
Iso, Kazuki
Kurokawa, Sayaka
Nakai, Toshiko
Hirayama, Atsushi
Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
title Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
title_full Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
title_fullStr Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
title_full_unstemmed Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
title_short Usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
title_sort usefulness of filtered unipolar electrogram morphology for evaluating transmurality of ablated lesions during pulmonary vein isolation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823572/
https://www.ncbi.nlm.nih.gov/pubmed/27092191
http://dx.doi.org/10.1016/j.joa.2015.10.001
work_keys_str_mv AT kogawarikitake usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT watanabeichiro usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT okumurayasuo usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT manohiroaki usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT sonodakazumasa usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT nagashimakoichi usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT sasakinaoko usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT ohkubokimie usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT takahashikeiko usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT isokazuki usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT kurokawasayaka usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT nakaitoshiko usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation
AT hirayamaatsushi usefulnessoffilteredunipolarelectrogrammorphologyforevaluatingtransmuralityofablatedlesionsduringpulmonaryveinisolation