Cargando…
Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial
BACKGROUND: To date no study has attempted to continuously evaluate changes in hemodynamics during delayed cord clamping in humans. We aimed to demonstrate 1. the feasibility of measurements of hemodynamics during delayed cord clamping and 2. to describe the changes that occur over each minute. RESU...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823677/ https://www.ncbi.nlm.nih.gov/pubmed/27057332 http://dx.doi.org/10.1186/s40748-015-0016-3 |
_version_ | 1782425960485748736 |
---|---|
author | Katheria, Anup C Wozniak, Madeline Harari, David Arnell, Kathy Petruzzelli, Deborah Finer, Neil N |
author_facet | Katheria, Anup C Wozniak, Madeline Harari, David Arnell, Kathy Petruzzelli, Deborah Finer, Neil N |
author_sort | Katheria, Anup C |
collection | PubMed |
description | BACKGROUND: To date no study has attempted to continuously evaluate changes in hemodynamics during delayed cord clamping in humans. We aimed to demonstrate 1. the feasibility of measurements of hemodynamics during delayed cord clamping and 2. to describe the changes that occur over each minute. RESULTS: After vaginal delivery, term infants (37(0)-41(6) weeks) were placed on a Life Start® bed 10–20 cm below the placenta. Transcutaneous sensors were placed on the neck and chest to determine heart rate, stroke volume and cardiac output at each beat. Once a signal was obtained, first 5 values (taken every beat) were averaged and the percent change for each subject from baseline was calculated. 20 infants were enrolled and all had a reliable signal obtained from transcutaneous sensors and had a delay in cord clamping for about 5 minutes. Cardiac output increased from 2 to 5 minutes of life (p = 0.008). For every minute of life the cord was kept unclamped, the stroke volume increased 13.1% ± 12.3 (p = 0.0001) and cardiac output increased 12.6% ± 6.3 from baseline (p < 0.0001). While the majority of infants continued to have an increase in cardiac output at 5 minutes of life, 7/20 infants reached their peak cardiac output at 188 ± 41 seconds of life. CONCLUSIONS: This study demonstrates that hemodynamic measures could be successfully obtained during the first five minutes of birth and while a newborn was receiving delayed cord clamping. This study also provides reference values for changes in cardiac output and stroke volume in well term infants during delayed cord clamping. TRIAL REGISTRATION: Clinical Trials.gov NCT02195037 Registered 17 July 2014 |
format | Online Article Text |
id | pubmed-4823677 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-48236772016-04-07 Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial Katheria, Anup C Wozniak, Madeline Harari, David Arnell, Kathy Petruzzelli, Deborah Finer, Neil N Matern Health Neonatol Perinatol Research Article BACKGROUND: To date no study has attempted to continuously evaluate changes in hemodynamics during delayed cord clamping in humans. We aimed to demonstrate 1. the feasibility of measurements of hemodynamics during delayed cord clamping and 2. to describe the changes that occur over each minute. RESULTS: After vaginal delivery, term infants (37(0)-41(6) weeks) were placed on a Life Start® bed 10–20 cm below the placenta. Transcutaneous sensors were placed on the neck and chest to determine heart rate, stroke volume and cardiac output at each beat. Once a signal was obtained, first 5 values (taken every beat) were averaged and the percent change for each subject from baseline was calculated. 20 infants were enrolled and all had a reliable signal obtained from transcutaneous sensors and had a delay in cord clamping for about 5 minutes. Cardiac output increased from 2 to 5 minutes of life (p = 0.008). For every minute of life the cord was kept unclamped, the stroke volume increased 13.1% ± 12.3 (p = 0.0001) and cardiac output increased 12.6% ± 6.3 from baseline (p < 0.0001). While the majority of infants continued to have an increase in cardiac output at 5 minutes of life, 7/20 infants reached their peak cardiac output at 188 ± 41 seconds of life. CONCLUSIONS: This study demonstrates that hemodynamic measures could be successfully obtained during the first five minutes of birth and while a newborn was receiving delayed cord clamping. This study also provides reference values for changes in cardiac output and stroke volume in well term infants during delayed cord clamping. TRIAL REGISTRATION: Clinical Trials.gov NCT02195037 Registered 17 July 2014 BioMed Central 2015-05-22 /pmc/articles/PMC4823677/ /pubmed/27057332 http://dx.doi.org/10.1186/s40748-015-0016-3 Text en © Katheria et al. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Katheria, Anup C Wozniak, Madeline Harari, David Arnell, Kathy Petruzzelli, Deborah Finer, Neil N Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial |
title | Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial |
title_full | Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial |
title_fullStr | Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial |
title_full_unstemmed | Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial |
title_short | Measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial |
title_sort | measuring cardiac changes using electrical impedance during delayed cord clamping: a feasibility trial |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823677/ https://www.ncbi.nlm.nih.gov/pubmed/27057332 http://dx.doi.org/10.1186/s40748-015-0016-3 |
work_keys_str_mv | AT katheriaanupc measuringcardiacchangesusingelectricalimpedanceduringdelayedcordclampingafeasibilitytrial AT wozniakmadeline measuringcardiacchangesusingelectricalimpedanceduringdelayedcordclampingafeasibilitytrial AT hararidavid measuringcardiacchangesusingelectricalimpedanceduringdelayedcordclampingafeasibilitytrial AT arnellkathy measuringcardiacchangesusingelectricalimpedanceduringdelayedcordclampingafeasibilitytrial AT petruzzellideborah measuringcardiacchangesusingelectricalimpedanceduringdelayedcordclampingafeasibilitytrial AT finerneiln measuringcardiacchangesusingelectricalimpedanceduringdelayedcordclampingafeasibilitytrial |