Cargando…
Saliva DNA quality and genotyping efficiency in a predominantly elderly population
BACKGROUND: The question of whether DNA obtained from saliva is an acceptable alternative to DNA from blood is a topic of considerable interest for large genetics studies. We compared the yields, quality and performance of DNAs from saliva and blood from a mostly elderly study population. METHODS: T...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823890/ https://www.ncbi.nlm.nih.gov/pubmed/27052975 http://dx.doi.org/10.1186/s12920-016-0172-y |
Sumario: | BACKGROUND: The question of whether DNA obtained from saliva is an acceptable alternative to DNA from blood is a topic of considerable interest for large genetics studies. We compared the yields, quality and performance of DNAs from saliva and blood from a mostly elderly study population. METHODS: Two thousand nine hundred ten DNAs from primarily elderly subjects (mean age ± standard deviation (SD): 65 ± 12 years), collected for the Primary Open-Angle African-American Glaucoma Genetics (POAAGG) study, were evaluated by fluorometry and/or spectroscopy. These included 566 DNAs from blood and 2344 from saliva. Subsets of these were evaluated by Sanger sequencing (n = 1555), and by microarray SNP genotyping (n = 94) on an Illumina OmniExpress bead chip platform. RESULTS: The mean age of subjects was 65, and 68 % were female in both the blood and saliva groups. The mean ± SD of DNA yield per ml of requested specimen was significantly higher for saliva (17.6 ± 17.8 μg/ml) than blood (13.2 ± 8.5 μg/ml), but the mean ± SD of total DNA yield obtained per saliva specimen (35 ± 36 μg from 2 ml maximum specimen volume) was approximately three-fold lower than from blood (106 ± 68 μg from 8 ml maximum specimen volume). The average genotyping call rates were >99 % for 43 of 44 saliva DNAs and >99 % for 50 of 50 for blood DNAs. For 22 of 23 paired blood and saliva samples from the same individuals, the average genotyping concordance rate was 99.996 %. High quality PCR Sanger sequencing was obtained from ≥ 98 % of blood (n = 297) and saliva (n = 1258) DNAs. DNA concentrations ≥10 ng/μl, corresponding to total yields ≥ 2 μg, were obtained for 94 % of the saliva specimens (n = 2344). CONCLUSIONS: In spite of inferior purity, the performance of saliva DNAs for microarray genotyping was excellent. Our results agree with other studies concluding that saliva collection is a viable alternative to blood. The potential to boost study enrollments and reduce subject discomfort is not necessarily offset by a reduction in genotyping efficiency. Saliva DNAs performed comparably to blood DNAs for PCR Sanger sequencing. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12920-016-0172-y) contains supplementary material, which is available to authorized users. |
---|