Cargando…
Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer
A newly developed compact measuring system for assessment of transmittance changes in the near-infrared spectral region is described; it allows deconvolution of redox changes due to ferredoxin (Fd), P700, and plastocyanin (PC) in intact leaves. In addition, it can also simultaneously measure chlorop...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4826414/ https://www.ncbi.nlm.nih.gov/pubmed/26837213 http://dx.doi.org/10.1007/s11120-016-0219-0 |
_version_ | 1782426329359056896 |
---|---|
author | Klughammer, Christof Schreiber, Ulrich |
author_facet | Klughammer, Christof Schreiber, Ulrich |
author_sort | Klughammer, Christof |
collection | PubMed |
description | A newly developed compact measuring system for assessment of transmittance changes in the near-infrared spectral region is described; it allows deconvolution of redox changes due to ferredoxin (Fd), P700, and plastocyanin (PC) in intact leaves. In addition, it can also simultaneously measure chlorophyll fluorescence. The major opto-electronic components as well as the principles of data acquisition and signal deconvolution are outlined. Four original pulse-modulated dual-wavelength difference signals are measured (785–840 nm, 810–870 nm, 870–970 nm, and 795–970 nm). Deconvolution is based on specific spectral information presented graphically in the form of ‘Differential Model Plots’ (DMP) of Fd, P700, and PC that are derived empirically from selective changes of these three components under appropriately chosen physiological conditions. Whereas information on maximal changes of Fd is obtained upon illumination after dark-acclimation, maximal changes of P700 and PC can be readily induced by saturating light pulses in the presence of far-red light. Using the information of DMP and maximal changes, the new measuring system enables on-line deconvolution of Fd, P700, and PC. The performance of the new device is demonstrated by some examples of practical applications, including fast measurements of flash relaxation kinetics and of the Fd, P700, and PC changes paralleling the polyphasic fluorescence rise upon application of a 300-ms pulse of saturating light. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11120-016-0219-0) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4826414 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-48264142016-04-20 Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer Klughammer, Christof Schreiber, Ulrich Photosynth Res Emerging Techniques A newly developed compact measuring system for assessment of transmittance changes in the near-infrared spectral region is described; it allows deconvolution of redox changes due to ferredoxin (Fd), P700, and plastocyanin (PC) in intact leaves. In addition, it can also simultaneously measure chlorophyll fluorescence. The major opto-electronic components as well as the principles of data acquisition and signal deconvolution are outlined. Four original pulse-modulated dual-wavelength difference signals are measured (785–840 nm, 810–870 nm, 870–970 nm, and 795–970 nm). Deconvolution is based on specific spectral information presented graphically in the form of ‘Differential Model Plots’ (DMP) of Fd, P700, and PC that are derived empirically from selective changes of these three components under appropriately chosen physiological conditions. Whereas information on maximal changes of Fd is obtained upon illumination after dark-acclimation, maximal changes of P700 and PC can be readily induced by saturating light pulses in the presence of far-red light. Using the information of DMP and maximal changes, the new measuring system enables on-line deconvolution of Fd, P700, and PC. The performance of the new device is demonstrated by some examples of practical applications, including fast measurements of flash relaxation kinetics and of the Fd, P700, and PC changes paralleling the polyphasic fluorescence rise upon application of a 300-ms pulse of saturating light. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11120-016-0219-0) contains supplementary material, which is available to authorized users. Springer Netherlands 2016-02-02 2016 /pmc/articles/PMC4826414/ /pubmed/26837213 http://dx.doi.org/10.1007/s11120-016-0219-0 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Emerging Techniques Klughammer, Christof Schreiber, Ulrich Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer |
title | Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer |
title_full | Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer |
title_fullStr | Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer |
title_full_unstemmed | Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer |
title_short | Deconvolution of ferredoxin, plastocyanin, and P700 transmittance changes in intact leaves with a new type of kinetic LED array spectrophotometer |
title_sort | deconvolution of ferredoxin, plastocyanin, and p700 transmittance changes in intact leaves with a new type of kinetic led array spectrophotometer |
topic | Emerging Techniques |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4826414/ https://www.ncbi.nlm.nih.gov/pubmed/26837213 http://dx.doi.org/10.1007/s11120-016-0219-0 |
work_keys_str_mv | AT klughammerchristof deconvolutionofferredoxinplastocyaninandp700transmittancechangesinintactleaveswithanewtypeofkineticledarrayspectrophotometer AT schreiberulrich deconvolutionofferredoxinplastocyaninandp700transmittancechangesinintactleaveswithanewtypeofkineticledarrayspectrophotometer |