Cargando…

Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease

BACKGROUND: All studies involving use of ionizing radiation should be performed in accordance with the ALARA (As Low As Reasonably Achievable) principle, especially in children. In this study, the prospective ECG triggering technique with low voltage was used in dual-source computed tomography (DSCT...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Ying, Li, Jian, Zhao, Hongliang, Jia, Yan, Ren, Jing, Xu, Jian, Hao, Yuewen, Zheng, Minwen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4826524/
https://www.ncbi.nlm.nih.gov/pubmed/27059600
http://dx.doi.org/10.1186/s13019-016-0460-9
_version_ 1782426347629445120
author Liu, Ying
Li, Jian
Zhao, Hongliang
Jia, Yan
Ren, Jing
Xu, Jian
Hao, Yuewen
Zheng, Minwen
author_facet Liu, Ying
Li, Jian
Zhao, Hongliang
Jia, Yan
Ren, Jing
Xu, Jian
Hao, Yuewen
Zheng, Minwen
author_sort Liu, Ying
collection PubMed
description BACKGROUND: All studies involving use of ionizing radiation should be performed in accordance with the ALARA (As Low As Reasonably Achievable) principle, especially in children. In this study, the prospective ECG triggering technique with low voltage was used in dual-source computed tomography (DSCT) angiography to investigate if image quality with low radiation dose could be satisfactory in pediatric patients with congenital heart disease. METHODS: Sixty pediatric patients with suspected congenital cardiovascular anomalies were enrolled prospectively in the study. They were randomly assigned to two groups for DSCT angiography. Group A were scanned by prospective ECG-triggering computed tomography angiography (CTA) with 80 kV tube voltage, while group B by used non-ECG-gated CTA with the same tube voltage. The anomaly accuracy was evaluated based on the surgical and/or conventional cardiac angiography findings. The overall image quality was assessed on a five-point scale. And the diagnostic accuracy and radiation dose was evaluated in both groups. RESULTS: There were 127 cardiovascular anomalies in Group A and 108 in Group B. The mean subjective image quality and diagnostic accuracy between these two groups were significantly different (P = 0.007 and 0.011, respectively). The mean effective dose in Group A and Group B was 0.38 ± 0.13 mSv and 0.35 ± 0.17 mSv, respectively. But there was no significant difference between two groups (P = 0.197). CONCLUSIONS: The prospective ECG triggering technique in DSCT scan can offer better image quality and diagnostic accuracy with low radiation exposure in pediatric patients with congenital heart diseases. This technique has potential to become a new clinical routine in pediatric cardiac computed tomography (CT) imaging.
format Online
Article
Text
id pubmed-4826524
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-48265242016-04-10 Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease Liu, Ying Li, Jian Zhao, Hongliang Jia, Yan Ren, Jing Xu, Jian Hao, Yuewen Zheng, Minwen J Cardiothorac Surg Research Article BACKGROUND: All studies involving use of ionizing radiation should be performed in accordance with the ALARA (As Low As Reasonably Achievable) principle, especially in children. In this study, the prospective ECG triggering technique with low voltage was used in dual-source computed tomography (DSCT) angiography to investigate if image quality with low radiation dose could be satisfactory in pediatric patients with congenital heart disease. METHODS: Sixty pediatric patients with suspected congenital cardiovascular anomalies were enrolled prospectively in the study. They were randomly assigned to two groups for DSCT angiography. Group A were scanned by prospective ECG-triggering computed tomography angiography (CTA) with 80 kV tube voltage, while group B by used non-ECG-gated CTA with the same tube voltage. The anomaly accuracy was evaluated based on the surgical and/or conventional cardiac angiography findings. The overall image quality was assessed on a five-point scale. And the diagnostic accuracy and radiation dose was evaluated in both groups. RESULTS: There were 127 cardiovascular anomalies in Group A and 108 in Group B. The mean subjective image quality and diagnostic accuracy between these two groups were significantly different (P = 0.007 and 0.011, respectively). The mean effective dose in Group A and Group B was 0.38 ± 0.13 mSv and 0.35 ± 0.17 mSv, respectively. But there was no significant difference between two groups (P = 0.197). CONCLUSIONS: The prospective ECG triggering technique in DSCT scan can offer better image quality and diagnostic accuracy with low radiation exposure in pediatric patients with congenital heart diseases. This technique has potential to become a new clinical routine in pediatric cardiac computed tomography (CT) imaging. BioMed Central 2016-04-09 /pmc/articles/PMC4826524/ /pubmed/27059600 http://dx.doi.org/10.1186/s13019-016-0460-9 Text en © Liu et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Liu, Ying
Li, Jian
Zhao, Hongliang
Jia, Yan
Ren, Jing
Xu, Jian
Hao, Yuewen
Zheng, Minwen
Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
title Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
title_full Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
title_fullStr Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
title_full_unstemmed Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
title_short Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
title_sort image quality and radiation dose of dual-source ct cardiac angiography using prospective ecg-triggering technique in pediatric patients with congenital heart disease
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4826524/
https://www.ncbi.nlm.nih.gov/pubmed/27059600
http://dx.doi.org/10.1186/s13019-016-0460-9
work_keys_str_mv AT liuying imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease
AT lijian imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease
AT zhaohongliang imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease
AT jiayan imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease
AT renjing imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease
AT xujian imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease
AT haoyuewen imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease
AT zhengminwen imagequalityandradiationdoseofdualsourcectcardiacangiographyusingprospectiveecgtriggeringtechniqueinpediatricpatientswithcongenitalheartdisease