Cargando…

Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone

Polyether ether ketone (PEEK) possesses excellent mechanical properties similar to those of human bone and is considered the best alternative material other than titanium for orthopedic spine and trauma implants. However, the deficient osteogenic properties and the bioinertness of PEEK limit its fie...

Descripción completa

Detalles Bibliográficos
Autores principales: Johansson, Pär, Jimbo, Ryo, Naito, Yoshihito, Kjellin, Per, Currie, Fredrik, Wennerberg, Ann
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4827897/
https://www.ncbi.nlm.nih.gov/pubmed/27103801
http://dx.doi.org/10.2147/IJN.S100424
_version_ 1782426530978201600
author Johansson, Pär
Jimbo, Ryo
Naito, Yoshihito
Kjellin, Per
Currie, Fredrik
Wennerberg, Ann
author_facet Johansson, Pär
Jimbo, Ryo
Naito, Yoshihito
Kjellin, Per
Currie, Fredrik
Wennerberg, Ann
author_sort Johansson, Pär
collection PubMed
description Polyether ether ketone (PEEK) possesses excellent mechanical properties similar to those of human bone and is considered the best alternative material other than titanium for orthopedic spine and trauma implants. However, the deficient osteogenic properties and the bioinertness of PEEK limit its fields of application. The aim of this study was to limit these drawbacks by coating the surface of PEEK with nano-scaled hydroxyapatite (HA) minerals. In the study, the biological response to PEEK, with and without HA coating, was investigated. Twenty-four screw-like and apically perforated implants in the rabbit femur were histologically evaluated at 3 weeks and 12 weeks after surgery. Twelve of the 24 implants were HA coated (test), and the remaining 12 served as uncoated PEEK controls. At 3 weeks and 12 weeks, the mean bone–implant contact was higher for test compared to control (P<0.05). The bone area inside the threads was comparable in the two groups, but the perforating hole showed more bone area for the HA-coated implants at both healing points (P<0.01). With these results, we conclude that nano-sized HA coating on PEEK implants significantly improved the osteogenic properties, and in a clinical situation this material composition may serve as an implant where a rapid bone fusion is essential.
format Online
Article
Text
id pubmed-4827897
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-48278972016-04-21 Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone Johansson, Pär Jimbo, Ryo Naito, Yoshihito Kjellin, Per Currie, Fredrik Wennerberg, Ann Int J Nanomedicine Original Research Polyether ether ketone (PEEK) possesses excellent mechanical properties similar to those of human bone and is considered the best alternative material other than titanium for orthopedic spine and trauma implants. However, the deficient osteogenic properties and the bioinertness of PEEK limit its fields of application. The aim of this study was to limit these drawbacks by coating the surface of PEEK with nano-scaled hydroxyapatite (HA) minerals. In the study, the biological response to PEEK, with and without HA coating, was investigated. Twenty-four screw-like and apically perforated implants in the rabbit femur were histologically evaluated at 3 weeks and 12 weeks after surgery. Twelve of the 24 implants were HA coated (test), and the remaining 12 served as uncoated PEEK controls. At 3 weeks and 12 weeks, the mean bone–implant contact was higher for test compared to control (P<0.05). The bone area inside the threads was comparable in the two groups, but the perforating hole showed more bone area for the HA-coated implants at both healing points (P<0.01). With these results, we conclude that nano-sized HA coating on PEEK implants significantly improved the osteogenic properties, and in a clinical situation this material composition may serve as an implant where a rapid bone fusion is essential. Dove Medical Press 2016-04-06 /pmc/articles/PMC4827897/ /pubmed/27103801 http://dx.doi.org/10.2147/IJN.S100424 Text en © 2016 Johansson et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Johansson, Pär
Jimbo, Ryo
Naito, Yoshihito
Kjellin, Per
Currie, Fredrik
Wennerberg, Ann
Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone
title Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone
title_full Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone
title_fullStr Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone
title_full_unstemmed Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone
title_short Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone
title_sort polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4827897/
https://www.ncbi.nlm.nih.gov/pubmed/27103801
http://dx.doi.org/10.2147/IJN.S100424
work_keys_str_mv AT johanssonpar polyetheretherketoneimplantsachieveincreasedbonefusionwhencoatedwithnanosizedhydroxyapatiteahistomorphometricstudyinrabbitbone
AT jimboryo polyetheretherketoneimplantsachieveincreasedbonefusionwhencoatedwithnanosizedhydroxyapatiteahistomorphometricstudyinrabbitbone
AT naitoyoshihito polyetheretherketoneimplantsachieveincreasedbonefusionwhencoatedwithnanosizedhydroxyapatiteahistomorphometricstudyinrabbitbone
AT kjellinper polyetheretherketoneimplantsachieveincreasedbonefusionwhencoatedwithnanosizedhydroxyapatiteahistomorphometricstudyinrabbitbone
AT curriefredrik polyetheretherketoneimplantsachieveincreasedbonefusionwhencoatedwithnanosizedhydroxyapatiteahistomorphometricstudyinrabbitbone
AT wennerbergann polyetheretherketoneimplantsachieveincreasedbonefusionwhencoatedwithnanosizedhydroxyapatiteahistomorphometricstudyinrabbitbone