Cargando…

Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity

This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a f...

Descripción completa

Detalles Bibliográficos
Autores principales: Brennan, Linda M., Widder, Mark W., McAleer, Michael K., Mayo, Michael W., Greis, Alex P., van der Schalie, William H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MyJove Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4828219/
https://www.ncbi.nlm.nih.gov/pubmed/27023147
http://dx.doi.org/10.3791/53555
_version_ 1782426548448526336
author Brennan, Linda M.
Widder, Mark W.
McAleer, Michael K.
Mayo, Michael W.
Greis, Alex P.
van der Schalie, William H.
author_facet Brennan, Linda M.
Widder, Mark W.
McAleer, Michael K.
Mayo, Michael W.
Greis, Alex P.
van der Schalie, William H.
author_sort Brennan, Linda M.
collection PubMed
description This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity testing of drinking water. The manuscript further describes how to run a toxicity test using the prepared biochips. A control water sample and the test water sample are mixed with pre-measured powdered media and injected into separate channels of the biochip. Impedance readings from the sensing electrodes in each of the biochip channels are measured and compared by an automated statistical software program. The screen on the ECIS instrument will indicate either "Contamination Detected" or "No Contamination Detected" within an hour of sample injection. Advantages are ease of use and rapid response to a broad spectrum of inorganic and organic chemicals at concentrations that are relevant to human health concerns, as well as the long-term stability of stored biochips in a ready state for testing. Limitations are the requirement for cold storage of the biochips and limited sensitivity to cholinesterase-inhibiting pesticides. Applications for this toxicity detector are for rapid field-portable testing of drinking water supplies by Army Preventative Medicine personnel or for use at municipal water treatment facilities.
format Online
Article
Text
id pubmed-4828219
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MyJove Corporation
record_format MEDLINE/PubMed
spelling pubmed-48282192016-04-22 Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity Brennan, Linda M. Widder, Mark W. McAleer, Michael K. Mayo, Michael W. Greis, Alex P. van der Schalie, William H. J Vis Exp Environmental Sciences This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity testing of drinking water. The manuscript further describes how to run a toxicity test using the prepared biochips. A control water sample and the test water sample are mixed with pre-measured powdered media and injected into separate channels of the biochip. Impedance readings from the sensing electrodes in each of the biochip channels are measured and compared by an automated statistical software program. The screen on the ECIS instrument will indicate either "Contamination Detected" or "No Contamination Detected" within an hour of sample injection. Advantages are ease of use and rapid response to a broad spectrum of inorganic and organic chemicals at concentrations that are relevant to human health concerns, as well as the long-term stability of stored biochips in a ready state for testing. Limitations are the requirement for cold storage of the biochips and limited sensitivity to cholinesterase-inhibiting pesticides. Applications for this toxicity detector are for rapid field-portable testing of drinking water supplies by Army Preventative Medicine personnel or for use at municipal water treatment facilities. MyJove Corporation 2016-03-07 /pmc/articles/PMC4828219/ /pubmed/27023147 http://dx.doi.org/10.3791/53555 Text en Copyright © 2016, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Environmental Sciences
Brennan, Linda M.
Widder, Mark W.
McAleer, Michael K.
Mayo, Michael W.
Greis, Alex P.
van der Schalie, William H.
Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
title Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
title_full Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
title_fullStr Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
title_full_unstemmed Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
title_short Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
title_sort preparation and testing of impedance-based fluidic biochips with rtgill-w1 cells for rapid evaluation of drinking water samples for toxicity
topic Environmental Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4828219/
https://www.ncbi.nlm.nih.gov/pubmed/27023147
http://dx.doi.org/10.3791/53555
work_keys_str_mv AT brennanlindam preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity
AT widdermarkw preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity
AT mcaleermichaelk preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity
AT mayomichaelw preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity
AT greisalexp preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity
AT vanderschaliewilliamh preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity