Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a f...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MyJove Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4828219/ https://www.ncbi.nlm.nih.gov/pubmed/27023147 http://dx.doi.org/10.3791/53555 |
_version_ | 1782426548448526336 |
---|---|
author | Brennan, Linda M. Widder, Mark W. McAleer, Michael K. Mayo, Michael W. Greis, Alex P. van der Schalie, William H. |
author_facet | Brennan, Linda M. Widder, Mark W. McAleer, Michael K. Mayo, Michael W. Greis, Alex P. van der Schalie, William H. |
author_sort | Brennan, Linda M. |
collection | PubMed |
description | This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity testing of drinking water. The manuscript further describes how to run a toxicity test using the prepared biochips. A control water sample and the test water sample are mixed with pre-measured powdered media and injected into separate channels of the biochip. Impedance readings from the sensing electrodes in each of the biochip channels are measured and compared by an automated statistical software program. The screen on the ECIS instrument will indicate either "Contamination Detected" or "No Contamination Detected" within an hour of sample injection. Advantages are ease of use and rapid response to a broad spectrum of inorganic and organic chemicals at concentrations that are relevant to human health concerns, as well as the long-term stability of stored biochips in a ready state for testing. Limitations are the requirement for cold storage of the biochips and limited sensitivity to cholinesterase-inhibiting pesticides. Applications for this toxicity detector are for rapid field-portable testing of drinking water supplies by Army Preventative Medicine personnel or for use at municipal water treatment facilities. |
format | Online Article Text |
id | pubmed-4828219 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MyJove Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-48282192016-04-22 Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity Brennan, Linda M. Widder, Mark W. McAleer, Michael K. Mayo, Michael W. Greis, Alex P. van der Schalie, William H. J Vis Exp Environmental Sciences This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity testing of drinking water. The manuscript further describes how to run a toxicity test using the prepared biochips. A control water sample and the test water sample are mixed with pre-measured powdered media and injected into separate channels of the biochip. Impedance readings from the sensing electrodes in each of the biochip channels are measured and compared by an automated statistical software program. The screen on the ECIS instrument will indicate either "Contamination Detected" or "No Contamination Detected" within an hour of sample injection. Advantages are ease of use and rapid response to a broad spectrum of inorganic and organic chemicals at concentrations that are relevant to human health concerns, as well as the long-term stability of stored biochips in a ready state for testing. Limitations are the requirement for cold storage of the biochips and limited sensitivity to cholinesterase-inhibiting pesticides. Applications for this toxicity detector are for rapid field-portable testing of drinking water supplies by Army Preventative Medicine personnel or for use at municipal water treatment facilities. MyJove Corporation 2016-03-07 /pmc/articles/PMC4828219/ /pubmed/27023147 http://dx.doi.org/10.3791/53555 Text en Copyright © 2016, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Environmental Sciences Brennan, Linda M. Widder, Mark W. McAleer, Michael K. Mayo, Michael W. Greis, Alex P. van der Schalie, William H. Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity |
title | Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity |
title_full | Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity |
title_fullStr | Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity |
title_full_unstemmed | Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity |
title_short | Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity |
title_sort | preparation and testing of impedance-based fluidic biochips with rtgill-w1 cells for rapid evaluation of drinking water samples for toxicity |
topic | Environmental Sciences |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4828219/ https://www.ncbi.nlm.nih.gov/pubmed/27023147 http://dx.doi.org/10.3791/53555 |
work_keys_str_mv | AT brennanlindam preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity AT widdermarkw preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity AT mcaleermichaelk preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity AT mayomichaelw preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity AT greisalexp preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity AT vanderschaliewilliamh preparationandtestingofimpedancebasedfluidicbiochipswithrtgillw1cellsforrapidevaluationofdrinkingwatersamplesfortoxicity |