Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla
BACKGROUND: To evaluate ungated nonenhanced hybridized arterial spin labeling (hASL) magnetic resonance angiography (MRA) of the extracranial carotid arteries using a fast low angle shot (FLASH) readout at 3 Tesla. METHODS: In this retrospective, institutional review board-approved and HIPAA-complia...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4828773/ https://www.ncbi.nlm.nih.gov/pubmed/27067840 http://dx.doi.org/10.1186/s12968-016-0238-1 |
_version_ | 1782426645552955392 |
---|---|
author | Koktzoglou, Ioannis Walker, Matthew T. Meyer, Joel R. Murphy, Ian G. Edelman, Robert R. |
author_facet | Koktzoglou, Ioannis Walker, Matthew T. Meyer, Joel R. Murphy, Ian G. Edelman, Robert R. |
author_sort | Koktzoglou, Ioannis |
collection | PubMed |
description | BACKGROUND: To evaluate ungated nonenhanced hybridized arterial spin labeling (hASL) magnetic resonance angiography (MRA) of the extracranial carotid arteries using a fast low angle shot (FLASH) readout at 3 Tesla. METHODS: In this retrospective, institutional review board-approved and HIPAA-compliant study, we evaluated the image quality (4-point scale) of nonenhanced hASL MRA using a FLASH readout with respect to contrast-enhanced MRA (CEMRA) in 37 patients presenting with neurologic symptoms. Two certified neuroradiologists independently evaluated 407 arterial segments (11 per patient) for image quality. The presence of vascular pathology was determined by consensus reading. Gwet’s AC1 was used to assess inter-rater agreement in image quality scores, and image quality scores were correlated with age and body mass index. Objective measurements of arterial lumen area and sharpness in the carotid arteries were compared to values obtained with CEMRA. Comparisons were also made with conventional nonenhanced 2D time-of-flight (TOF) MRA. RESULTS: CEMRA provided the best image quality, while nonenhanced hASL FLASH MRA provided image quality that exceeded 2D TOF at the carotid bifurcation and in the internal and external carotid arteries. All nine vascular abnormalities of the carotid and intracranial arteries detected by CEMRA were depicted with hASL MRA, with no false positives. Inter-rater agreement of image quality scores was highest for CEMRA (AC1 = 0.87), followed by hASL (AC1 = 0.61) and TOF (AC1 = 0.43) (P < 0.001, all comparisons). With respect to CEMRA, agreement in cross-sectional lumen area was significantly better with hASL than TOF in the common carotid artery (intraclass correlation (ICC) = 0.90 versus 0.66; P < 0.05) and at the carotid bifurcation (ICC = 0.87 versus 0.54; P < 0.05). Nonenhanced hASL MRA provided superior arterial sharpness with respect to CEMRA and 2D TOF (P < 0.001). CONCLUSION: Although inferior to CEMRA in terms of image quality and inter-rater agreement, hASL FLASH MRA offers an alternative to 2D TOF for the nonenhanced evaluation of the extracranial carotid arteries at 3 Tesla. Compared with 2D TOF, nonenhanced hASL FLASH MRA provides improved quantification of arterial cross-sectional area, vessel sharpness, inter-rater agreement and image quality. |
format | Online Article Text |
id | pubmed-4828773 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-48287732016-04-13 Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla Koktzoglou, Ioannis Walker, Matthew T. Meyer, Joel R. Murphy, Ian G. Edelman, Robert R. J Cardiovasc Magn Reson Research BACKGROUND: To evaluate ungated nonenhanced hybridized arterial spin labeling (hASL) magnetic resonance angiography (MRA) of the extracranial carotid arteries using a fast low angle shot (FLASH) readout at 3 Tesla. METHODS: In this retrospective, institutional review board-approved and HIPAA-compliant study, we evaluated the image quality (4-point scale) of nonenhanced hASL MRA using a FLASH readout with respect to contrast-enhanced MRA (CEMRA) in 37 patients presenting with neurologic symptoms. Two certified neuroradiologists independently evaluated 407 arterial segments (11 per patient) for image quality. The presence of vascular pathology was determined by consensus reading. Gwet’s AC1 was used to assess inter-rater agreement in image quality scores, and image quality scores were correlated with age and body mass index. Objective measurements of arterial lumen area and sharpness in the carotid arteries were compared to values obtained with CEMRA. Comparisons were also made with conventional nonenhanced 2D time-of-flight (TOF) MRA. RESULTS: CEMRA provided the best image quality, while nonenhanced hASL FLASH MRA provided image quality that exceeded 2D TOF at the carotid bifurcation and in the internal and external carotid arteries. All nine vascular abnormalities of the carotid and intracranial arteries detected by CEMRA were depicted with hASL MRA, with no false positives. Inter-rater agreement of image quality scores was highest for CEMRA (AC1 = 0.87), followed by hASL (AC1 = 0.61) and TOF (AC1 = 0.43) (P < 0.001, all comparisons). With respect to CEMRA, agreement in cross-sectional lumen area was significantly better with hASL than TOF in the common carotid artery (intraclass correlation (ICC) = 0.90 versus 0.66; P < 0.05) and at the carotid bifurcation (ICC = 0.87 versus 0.54; P < 0.05). Nonenhanced hASL MRA provided superior arterial sharpness with respect to CEMRA and 2D TOF (P < 0.001). CONCLUSION: Although inferior to CEMRA in terms of image quality and inter-rater agreement, hASL FLASH MRA offers an alternative to 2D TOF for the nonenhanced evaluation of the extracranial carotid arteries at 3 Tesla. Compared with 2D TOF, nonenhanced hASL FLASH MRA provides improved quantification of arterial cross-sectional area, vessel sharpness, inter-rater agreement and image quality. BioMed Central 2016-04-12 /pmc/articles/PMC4828773/ /pubmed/27067840 http://dx.doi.org/10.1186/s12968-016-0238-1 Text en © Koktzoglou et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Koktzoglou, Ioannis Walker, Matthew T. Meyer, Joel R. Murphy, Ian G. Edelman, Robert R. Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla |
title | Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla |
title_full | Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla |
title_fullStr | Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla |
title_full_unstemmed | Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla |
title_short | Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla |
title_sort | nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 tesla |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4828773/ https://www.ncbi.nlm.nih.gov/pubmed/27067840 http://dx.doi.org/10.1186/s12968-016-0238-1 |
work_keys_str_mv | AT koktzoglouioannis nonenhancedhybridizedarterialspinlabeledmagneticresonanceangiographyoftheextracranialcarotidarteriesusingafastlowangleshotreadoutat3tesla AT walkermatthewt nonenhancedhybridizedarterialspinlabeledmagneticresonanceangiographyoftheextracranialcarotidarteriesusingafastlowangleshotreadoutat3tesla AT meyerjoelr nonenhancedhybridizedarterialspinlabeledmagneticresonanceangiographyoftheextracranialcarotidarteriesusingafastlowangleshotreadoutat3tesla AT murphyiang nonenhancedhybridizedarterialspinlabeledmagneticresonanceangiographyoftheextracranialcarotidarteriesusingafastlowangleshotreadoutat3tesla AT edelmanrobertr nonenhancedhybridizedarterialspinlabeledmagneticresonanceangiographyoftheextracranialcarotidarteriesusingafastlowangleshotreadoutat3tesla |