Cargando…

Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion

BACKGROUND: A high P-wave duration and dispersion (Pd) have been reported to be a prognostic factor for the occurrence of paroxysmal atrial fibrillation (PAF), a condition linked to obstructive sleep apnea (OSA). We tested the hypothesis of whether a short-term increase of P-wave duration and Pd can...

Descripción completa

Detalles Bibliográficos
Autores principales: Gaisl, Thomas, Wons, Annette M., Rossi, Valentina, Bratton, Daniel J., Schlatzer, Christian, Schwarz, Esther I., Camen, Giovanni, Kohler, Malcolm
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4829247/
https://www.ncbi.nlm.nih.gov/pubmed/27071039
http://dx.doi.org/10.1371/journal.pone.0152994
_version_ 1782426724627120128
author Gaisl, Thomas
Wons, Annette M.
Rossi, Valentina
Bratton, Daniel J.
Schlatzer, Christian
Schwarz, Esther I.
Camen, Giovanni
Kohler, Malcolm
author_facet Gaisl, Thomas
Wons, Annette M.
Rossi, Valentina
Bratton, Daniel J.
Schlatzer, Christian
Schwarz, Esther I.
Camen, Giovanni
Kohler, Malcolm
author_sort Gaisl, Thomas
collection PubMed
description BACKGROUND: A high P-wave duration and dispersion (Pd) have been reported to be a prognostic factor for the occurrence of paroxysmal atrial fibrillation (PAF), a condition linked to obstructive sleep apnea (OSA). We tested the hypothesis of whether a short-term increase of P-wave duration and Pd can be induced by respiratory manoeuvres simulating OSA in healthy subjects and in patients with PAF. METHODS: 12-lead-electrocardiography (ECG) was recorded continuously in 24 healthy subjects and 33 patients with PAF, while simulating obstructive apnea (Mueller manoeuvre, MM), obstructive hypopnea (inspiration through a threshold load, ITH), central apnea (AP), and during normal breathing (BL) in randomized order. The P-wave duration and Pd was calculated by using dedicated software for ECG-analysis. RESULTS: P-wave duration and Pd significantly increased during MM and ITH compared to BL in all subjects (+13.1ms and +13.8ms during MM; +11.7ms and +12.9ms during ITH; p<0.001 for all comparisons). In MM, the increase was larger in healthy subjects when compared to patients with PAF (p<0.05). CONCLUSION: Intrathoracic pressure swings through simulated obstructive sleep apnea increase P-wave duration and Pd in healthy subjects and in patients with PAF. Our findings imply that intrathoracic pressure swings prolong the intra-atrial and inter-atrial conduction time and therefore may represent an independent trigger factor for the development for PAF.
format Online
Article
Text
id pubmed-4829247
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-48292472016-04-22 Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion Gaisl, Thomas Wons, Annette M. Rossi, Valentina Bratton, Daniel J. Schlatzer, Christian Schwarz, Esther I. Camen, Giovanni Kohler, Malcolm PLoS One Research Article BACKGROUND: A high P-wave duration and dispersion (Pd) have been reported to be a prognostic factor for the occurrence of paroxysmal atrial fibrillation (PAF), a condition linked to obstructive sleep apnea (OSA). We tested the hypothesis of whether a short-term increase of P-wave duration and Pd can be induced by respiratory manoeuvres simulating OSA in healthy subjects and in patients with PAF. METHODS: 12-lead-electrocardiography (ECG) was recorded continuously in 24 healthy subjects and 33 patients with PAF, while simulating obstructive apnea (Mueller manoeuvre, MM), obstructive hypopnea (inspiration through a threshold load, ITH), central apnea (AP), and during normal breathing (BL) in randomized order. The P-wave duration and Pd was calculated by using dedicated software for ECG-analysis. RESULTS: P-wave duration and Pd significantly increased during MM and ITH compared to BL in all subjects (+13.1ms and +13.8ms during MM; +11.7ms and +12.9ms during ITH; p<0.001 for all comparisons). In MM, the increase was larger in healthy subjects when compared to patients with PAF (p<0.05). CONCLUSION: Intrathoracic pressure swings through simulated obstructive sleep apnea increase P-wave duration and Pd in healthy subjects and in patients with PAF. Our findings imply that intrathoracic pressure swings prolong the intra-atrial and inter-atrial conduction time and therefore may represent an independent trigger factor for the development for PAF. Public Library of Science 2016-04-12 /pmc/articles/PMC4829247/ /pubmed/27071039 http://dx.doi.org/10.1371/journal.pone.0152994 Text en © 2016 Gaisl et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Gaisl, Thomas
Wons, Annette M.
Rossi, Valentina
Bratton, Daniel J.
Schlatzer, Christian
Schwarz, Esther I.
Camen, Giovanni
Kohler, Malcolm
Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion
title Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion
title_full Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion
title_fullStr Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion
title_full_unstemmed Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion
title_short Simulated Obstructive Sleep Apnea Increases P-Wave Duration and P-Wave Dispersion
title_sort simulated obstructive sleep apnea increases p-wave duration and p-wave dispersion
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4829247/
https://www.ncbi.nlm.nih.gov/pubmed/27071039
http://dx.doi.org/10.1371/journal.pone.0152994
work_keys_str_mv AT gaislthomas simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion
AT wonsannettem simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion
AT rossivalentina simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion
AT brattondanielj simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion
AT schlatzerchristian simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion
AT schwarzestheri simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion
AT camengiovanni simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion
AT kohlermalcolm simulatedobstructivesleepapneaincreasespwavedurationandpwavedispersion