Cargando…
Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature
Introduction. We report a case of spontaneous rupture of a single testicular prosthesis in a patient who had undergone bilateral orchiectomy and silicone gel-filled prosthesis insertion. The consequences of this rare event are discussed. There is no management algorithm. Case Presentation. A 55-year...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4829707/ https://www.ncbi.nlm.nih.gov/pubmed/27123354 http://dx.doi.org/10.1155/2016/2824802 |
_version_ | 1782426786097790976 |
---|---|
author | Phan, Quang-Bao Koutlidis, Nicolas Duperron, Céline Mourey, Eric Michel, Frédéric Cormier, Luc |
author_facet | Phan, Quang-Bao Koutlidis, Nicolas Duperron, Céline Mourey, Eric Michel, Frédéric Cormier, Luc |
author_sort | Phan, Quang-Bao |
collection | PubMed |
description | Introduction. We report a case of spontaneous rupture of a single testicular prosthesis in a patient who had undergone bilateral orchiectomy and silicone gel-filled prosthesis insertion. The consequences of this rare event are discussed. There is no management algorithm. Case Presentation. A 55-year-old man presented to our outpatient department with altered consistency in his right testicular prosthesis and a painful right hemiscrotum with no systemic symptoms thirty-three years after the implantation of the prosthesis. We removed this implant without replacement, in accordance with the patient's wishes. Conclusion. The long time between the implantation and the spontaneous rupture is remarkable and was never before described. The removal of the prosthesis was straightforward and it would have been possible to implant a new prosthesis after taking into account the condition of the skin. |
format | Online Article Text |
id | pubmed-4829707 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-48297072016-04-27 Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature Phan, Quang-Bao Koutlidis, Nicolas Duperron, Céline Mourey, Eric Michel, Frédéric Cormier, Luc Case Rep Urol Case Report Introduction. We report a case of spontaneous rupture of a single testicular prosthesis in a patient who had undergone bilateral orchiectomy and silicone gel-filled prosthesis insertion. The consequences of this rare event are discussed. There is no management algorithm. Case Presentation. A 55-year-old man presented to our outpatient department with altered consistency in his right testicular prosthesis and a painful right hemiscrotum with no systemic symptoms thirty-three years after the implantation of the prosthesis. We removed this implant without replacement, in accordance with the patient's wishes. Conclusion. The long time between the implantation and the spontaneous rupture is remarkable and was never before described. The removal of the prosthesis was straightforward and it would have been possible to implant a new prosthesis after taking into account the condition of the skin. Hindawi Publishing Corporation 2016 2016-03-30 /pmc/articles/PMC4829707/ /pubmed/27123354 http://dx.doi.org/10.1155/2016/2824802 Text en Copyright © 2016 Quang-Bao Phan et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Phan, Quang-Bao Koutlidis, Nicolas Duperron, Céline Mourey, Eric Michel, Frédéric Cormier, Luc Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature |
title | Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature |
title_full | Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature |
title_fullStr | Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature |
title_full_unstemmed | Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature |
title_short | Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature |
title_sort | management of testicular silicone gel-filled prosthesis rupture: case report of a rare event and a review of the literature |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4829707/ https://www.ncbi.nlm.nih.gov/pubmed/27123354 http://dx.doi.org/10.1155/2016/2824802 |
work_keys_str_mv | AT phanquangbao managementoftesticularsiliconegelfilledprosthesisrupturecasereportofarareeventandareviewoftheliterature AT koutlidisnicolas managementoftesticularsiliconegelfilledprosthesisrupturecasereportofarareeventandareviewoftheliterature AT duperronceline managementoftesticularsiliconegelfilledprosthesisrupturecasereportofarareeventandareviewoftheliterature AT moureyeric managementoftesticularsiliconegelfilledprosthesisrupturecasereportofarareeventandareviewoftheliterature AT michelfrederic managementoftesticularsiliconegelfilledprosthesisrupturecasereportofarareeventandareviewoftheliterature AT cormierluc managementoftesticularsiliconegelfilledprosthesisrupturecasereportofarareeventandareviewoftheliterature |