Cargando…

Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis

OBJECTIVES: To evaluate the effect of moments and the combination of forces and moments on the mechanical properties of a bracket type miniscrew, resembling engagement of a rectangular wire by three-dimensional (3D) finite element study. MATERIALS AND METHODS: By solid work software (Dassaunlt syste...

Descripción completa

Detalles Bibliográficos
Autores principales: Ajami, Shabnam, Mina, Ahmad, Nabavizadeh, Seyed Amin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4830140/
https://www.ncbi.nlm.nih.gov/pubmed/27127753
http://dx.doi.org/10.4103/2278-0203.179416
_version_ 1782426859962630144
author Ajami, Shabnam
Mina, Ahmad
Nabavizadeh, Seyed Amin
author_facet Ajami, Shabnam
Mina, Ahmad
Nabavizadeh, Seyed Amin
author_sort Ajami, Shabnam
collection PubMed
description OBJECTIVES: To evaluate the effect of moments and the combination of forces and moments on the mechanical properties of a bracket type miniscrew, resembling engagement of a rectangular wire by three-dimensional (3D) finite element study. MATERIALS AND METHODS: By solid work software (Dassaunlt systems solid works, concord, Mass), a 3D miniscrew model of 6, 8, 10 mm lengths was designed and inserted in the osseous block, consisted of the cortical, and cancellous bones. The stress distributions, maximum stresses, and deflections of the miniscrew were evaluated for all parts using ANSYS (Work Bench, 2014). RESULTS: As the magnitudes of the load increased from 100 to 200, 400 and 800 grf-mm, the peak of stresses in the 6 mm long miniscrew were increased from 7.7 to 61.5 Mpa. The maximum values of Von Mises in the cancellous bone were tremendously lower in comparison to the cortical bone by one hundredth. As the length of the miniscrew in contact with the bone was increased, the amounts and patterns of stress distribution in the cortical bone and the miniscrew did not change significantly. CONCLUSIONS: As the moment magnitude increased, the pick stresses increased linearly. The existence of cancellous bone was not significantly responsible for the stress distribution. The pattern of stress distribution did not change by the length of the miniscrew.
format Online
Article
Text
id pubmed-4830140
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-48301402016-04-28 Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis Ajami, Shabnam Mina, Ahmad Nabavizadeh, Seyed Amin J Orthod Sci Original Article OBJECTIVES: To evaluate the effect of moments and the combination of forces and moments on the mechanical properties of a bracket type miniscrew, resembling engagement of a rectangular wire by three-dimensional (3D) finite element study. MATERIALS AND METHODS: By solid work software (Dassaunlt systems solid works, concord, Mass), a 3D miniscrew model of 6, 8, 10 mm lengths was designed and inserted in the osseous block, consisted of the cortical, and cancellous bones. The stress distributions, maximum stresses, and deflections of the miniscrew were evaluated for all parts using ANSYS (Work Bench, 2014). RESULTS: As the magnitudes of the load increased from 100 to 200, 400 and 800 grf-mm, the peak of stresses in the 6 mm long miniscrew were increased from 7.7 to 61.5 Mpa. The maximum values of Von Mises in the cancellous bone were tremendously lower in comparison to the cortical bone by one hundredth. As the length of the miniscrew in contact with the bone was increased, the amounts and patterns of stress distribution in the cortical bone and the miniscrew did not change significantly. CONCLUSIONS: As the moment magnitude increased, the pick stresses increased linearly. The existence of cancellous bone was not significantly responsible for the stress distribution. The pattern of stress distribution did not change by the length of the miniscrew. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4830140/ /pubmed/27127753 http://dx.doi.org/10.4103/2278-0203.179416 Text en Copyright: © Journal of Orthodontic Science http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ajami, Shabnam
Mina, Ahmad
Nabavizadeh, Seyed Amin
Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis
title Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis
title_full Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis
title_fullStr Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis
title_full_unstemmed Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis
title_short Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis
title_sort stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: three-dimensional finite element analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4830140/
https://www.ncbi.nlm.nih.gov/pubmed/27127753
http://dx.doi.org/10.4103/2278-0203.179416
work_keys_str_mv AT ajamishabnam stressdistributionsofabrackettypeorthodonticminiscrewandthesurroundingboneundermomentloadingsthreedimensionalfiniteelementanalysis
AT minaahmad stressdistributionsofabrackettypeorthodonticminiscrewandthesurroundingboneundermomentloadingsthreedimensionalfiniteelementanalysis
AT nabavizadehseyedamin stressdistributionsofabrackettypeorthodonticminiscrewandthesurroundingboneundermomentloadingsthreedimensionalfiniteelementanalysis