Cargando…
3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study
BACKGROUND: Pre-clinical detection of atherosclerosis enables personalized preventive strategies in asymptomatic individuals. Cardiovascular magnetic resonance (CMR) has evolved as an attractive imaging modality for studying atherosclerosis in vivo. Yet, the majority of aortic CMR studies and propos...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4831203/ https://www.ncbi.nlm.nih.gov/pubmed/27075677 http://dx.doi.org/10.1186/s12968-016-0237-2 |
_version_ | 1782427027386662912 |
---|---|
author | Eikendal, Anouk L. M. Blomberg, Björn A. Haaring, Cees Saam, Tobias van der Geest, Rob J. Visser, Fredy Bots, Michiel L. den Ruijter, Hester M. Hoefer, Imo E. Leiner, Tim |
author_facet | Eikendal, Anouk L. M. Blomberg, Björn A. Haaring, Cees Saam, Tobias van der Geest, Rob J. Visser, Fredy Bots, Michiel L. den Ruijter, Hester M. Hoefer, Imo E. Leiner, Tim |
author_sort | Eikendal, Anouk L. M. |
collection | PubMed |
description | BACKGROUND: Pre-clinical detection of atherosclerosis enables personalized preventive strategies in asymptomatic individuals. Cardiovascular magnetic resonance (CMR) has evolved as an attractive imaging modality for studying atherosclerosis in vivo. Yet, the majority of aortic CMR studies and proposed sequences to date have been performed at 1.5 tesla using 2D BB techniques and a slice thickness of 4–5 mm. Here, we evaluate for the first time the reproducibility of an isotropic, T1-weighted, three-dimensional, black-blood, CMR VISTA sequence (3D-T1-BB-VISTA) for quantification of aortic wall characteristics in healthy, young adults. METHODS: In 20 healthy, young adults (10 males, mean age 31.3 years) of the AMBITYON cohort study the descending thoracic aorta was imaged with a 3.0 T MR system using the 3D-T1-BB-VISTA sequence. The inter-scan, inter-rater and intra-rater reproducibility of aortic lumen, total vessel and wall area and mean and maximum wall thickness was evaluated using Bland-Altman analyses and Intraclass Correlation Coefficients (ICC). Based on these findings, sample sizes for detecting differences in aortic wall characteristics between groups were calculated. RESULTS: For each studied parameter, the inter-scan, inter-rater and intra-rater reproducibility was excellent as indicated by narrow limits of agreement and high ICCs (ranging from 0.76 to 0.99). Sample sizes required to detect a 5 % difference in aortic wall characteristics between two groups were 203, 126, 136, 68 and 153 per group for lumen area, total vessel area and vessel wall area and for mean and maximum vessel wall thickness, respectively. CONCLUSION: The 3D-T1-BB-VISTA sequence provides excellent reproducibility for quantification of aortic wall characteristics and can detect small differences between groups with reasonable sample sizes. Hence, it may be a valuable tool for assessment of the subtle vascular wall changes of early atherosclerosis in asymptomatic populations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-016-0237-2) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4831203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-48312032016-04-15 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study Eikendal, Anouk L. M. Blomberg, Björn A. Haaring, Cees Saam, Tobias van der Geest, Rob J. Visser, Fredy Bots, Michiel L. den Ruijter, Hester M. Hoefer, Imo E. Leiner, Tim J Cardiovasc Magn Reson Research BACKGROUND: Pre-clinical detection of atherosclerosis enables personalized preventive strategies in asymptomatic individuals. Cardiovascular magnetic resonance (CMR) has evolved as an attractive imaging modality for studying atherosclerosis in vivo. Yet, the majority of aortic CMR studies and proposed sequences to date have been performed at 1.5 tesla using 2D BB techniques and a slice thickness of 4–5 mm. Here, we evaluate for the first time the reproducibility of an isotropic, T1-weighted, three-dimensional, black-blood, CMR VISTA sequence (3D-T1-BB-VISTA) for quantification of aortic wall characteristics in healthy, young adults. METHODS: In 20 healthy, young adults (10 males, mean age 31.3 years) of the AMBITYON cohort study the descending thoracic aorta was imaged with a 3.0 T MR system using the 3D-T1-BB-VISTA sequence. The inter-scan, inter-rater and intra-rater reproducibility of aortic lumen, total vessel and wall area and mean and maximum wall thickness was evaluated using Bland-Altman analyses and Intraclass Correlation Coefficients (ICC). Based on these findings, sample sizes for detecting differences in aortic wall characteristics between groups were calculated. RESULTS: For each studied parameter, the inter-scan, inter-rater and intra-rater reproducibility was excellent as indicated by narrow limits of agreement and high ICCs (ranging from 0.76 to 0.99). Sample sizes required to detect a 5 % difference in aortic wall characteristics between two groups were 203, 126, 136, 68 and 153 per group for lumen area, total vessel area and vessel wall area and for mean and maximum vessel wall thickness, respectively. CONCLUSION: The 3D-T1-BB-VISTA sequence provides excellent reproducibility for quantification of aortic wall characteristics and can detect small differences between groups with reasonable sample sizes. Hence, it may be a valuable tool for assessment of the subtle vascular wall changes of early atherosclerosis in asymptomatic populations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-016-0237-2) contains supplementary material, which is available to authorized users. BioMed Central 2016-04-14 /pmc/articles/PMC4831203/ /pubmed/27075677 http://dx.doi.org/10.1186/s12968-016-0237-2 Text en © Eikendal et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Eikendal, Anouk L. M. Blomberg, Björn A. Haaring, Cees Saam, Tobias van der Geest, Rob J. Visser, Fredy Bots, Michiel L. den Ruijter, Hester M. Hoefer, Imo E. Leiner, Tim 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study |
title | 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study |
title_full | 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study |
title_fullStr | 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study |
title_full_unstemmed | 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study |
title_short | 3D black blood VISTA vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study |
title_sort | 3d black blood vista vessel wall cardiovascular magnetic resonance of the thoracic aorta wall in young, healthy adults: reproducibility and implications for efficacy trial sample sizes: a cross-sectional study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4831203/ https://www.ncbi.nlm.nih.gov/pubmed/27075677 http://dx.doi.org/10.1186/s12968-016-0237-2 |
work_keys_str_mv | AT eikendalanouklm 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT blombergbjorna 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT haaringcees 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT saamtobias 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT vandergeestrobj 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT visserfredy 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT botsmichiell 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT denruijterhesterm 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT hoeferimoe 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy AT leinertim 3dblackbloodvistavesselwallcardiovascularmagneticresonanceofthethoracicaortawallinyounghealthyadultsreproducibilityandimplicationsforefficacytrialsamplesizesacrosssectionalstudy |