Cargando…

Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement

INTRODUCTION: The incidence of cemented femoral stem migration and dislodgement even though has been described is extremely unusual. There is a high chance of polished femoral stem displacement happening while trying to reduce a dislocated total hip replacement by closed measures. PRESENTATION OF TH...

Descripción completa

Detalles Bibliográficos
Autores principales: Rajeev, Aysha, Mohamed, Abdalla, Shaikh, Mazharuddin, Banaszkiewicz, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4832038/
https://www.ncbi.nlm.nih.gov/pubmed/27060643
http://dx.doi.org/10.1016/j.ijscr.2016.03.019
_version_ 1782427180967395328
author Rajeev, Aysha
Mohamed, Abdalla
Shaikh, Mazharuddin
Banaszkiewicz, Paul
author_facet Rajeev, Aysha
Mohamed, Abdalla
Shaikh, Mazharuddin
Banaszkiewicz, Paul
author_sort Rajeev, Aysha
collection PubMed
description INTRODUCTION: The incidence of cemented femoral stem migration and dislodgement even though has been described is extremely unusual. There is a high chance of polished femoral stem displacement happening while trying to reduce a dislocated total hip replacement by closed measures. PRESENTATION OF THE CASE: A 73 year old lady who had an Exeter cemented total hip replacement about two weeks back was admitted from Accident and Emergency with a dislocation. During the closed manipulative reduction under general anaesthesia it was noted that the femoral stem has dislodged from the canal. She underwent revision of the total hip replacement with good outcome. DISCUSSION: Femoral stem dislodgement occurs in total hip replacement if polished stem or inadequate cementing of the collar is carried out. CONCLUSION: Gentle manipulative reduction under general anaesthesia of dislocated total hip replacement should be carried out if the polished femoral stem is used.
format Online
Article
Text
id pubmed-4832038
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-48320382016-04-25 Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement Rajeev, Aysha Mohamed, Abdalla Shaikh, Mazharuddin Banaszkiewicz, Paul Int J Surg Case Rep Case Report INTRODUCTION: The incidence of cemented femoral stem migration and dislodgement even though has been described is extremely unusual. There is a high chance of polished femoral stem displacement happening while trying to reduce a dislocated total hip replacement by closed measures. PRESENTATION OF THE CASE: A 73 year old lady who had an Exeter cemented total hip replacement about two weeks back was admitted from Accident and Emergency with a dislocation. During the closed manipulative reduction under general anaesthesia it was noted that the femoral stem has dislodged from the canal. She underwent revision of the total hip replacement with good outcome. DISCUSSION: Femoral stem dislodgement occurs in total hip replacement if polished stem or inadequate cementing of the collar is carried out. CONCLUSION: Gentle manipulative reduction under general anaesthesia of dislocated total hip replacement should be carried out if the polished femoral stem is used. Elsevier 2016-03-18 /pmc/articles/PMC4832038/ /pubmed/27060643 http://dx.doi.org/10.1016/j.ijscr.2016.03.019 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Rajeev, Aysha
Mohamed, Abdalla
Shaikh, Mazharuddin
Banaszkiewicz, Paul
Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
title Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
title_full Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
title_fullStr Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
title_full_unstemmed Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
title_short Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
title_sort dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4832038/
https://www.ncbi.nlm.nih.gov/pubmed/27060643
http://dx.doi.org/10.1016/j.ijscr.2016.03.019
work_keys_str_mv AT rajeevaysha dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement
AT mohamedabdalla dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement
AT shaikhmazharuddin dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement
AT banaszkiewiczpaul dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement