Cargando…
Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement
INTRODUCTION: The incidence of cemented femoral stem migration and dislodgement even though has been described is extremely unusual. There is a high chance of polished femoral stem displacement happening while trying to reduce a dislocated total hip replacement by closed measures. PRESENTATION OF TH...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4832038/ https://www.ncbi.nlm.nih.gov/pubmed/27060643 http://dx.doi.org/10.1016/j.ijscr.2016.03.019 |
_version_ | 1782427180967395328 |
---|---|
author | Rajeev, Aysha Mohamed, Abdalla Shaikh, Mazharuddin Banaszkiewicz, Paul |
author_facet | Rajeev, Aysha Mohamed, Abdalla Shaikh, Mazharuddin Banaszkiewicz, Paul |
author_sort | Rajeev, Aysha |
collection | PubMed |
description | INTRODUCTION: The incidence of cemented femoral stem migration and dislodgement even though has been described is extremely unusual. There is a high chance of polished femoral stem displacement happening while trying to reduce a dislocated total hip replacement by closed measures. PRESENTATION OF THE CASE: A 73 year old lady who had an Exeter cemented total hip replacement about two weeks back was admitted from Accident and Emergency with a dislocation. During the closed manipulative reduction under general anaesthesia it was noted that the femoral stem has dislodged from the canal. She underwent revision of the total hip replacement with good outcome. DISCUSSION: Femoral stem dislodgement occurs in total hip replacement if polished stem or inadequate cementing of the collar is carried out. CONCLUSION: Gentle manipulative reduction under general anaesthesia of dislocated total hip replacement should be carried out if the polished femoral stem is used. |
format | Online Article Text |
id | pubmed-4832038 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-48320382016-04-25 Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement Rajeev, Aysha Mohamed, Abdalla Shaikh, Mazharuddin Banaszkiewicz, Paul Int J Surg Case Rep Case Report INTRODUCTION: The incidence of cemented femoral stem migration and dislodgement even though has been described is extremely unusual. There is a high chance of polished femoral stem displacement happening while trying to reduce a dislocated total hip replacement by closed measures. PRESENTATION OF THE CASE: A 73 year old lady who had an Exeter cemented total hip replacement about two weeks back was admitted from Accident and Emergency with a dislocation. During the closed manipulative reduction under general anaesthesia it was noted that the femoral stem has dislodged from the canal. She underwent revision of the total hip replacement with good outcome. DISCUSSION: Femoral stem dislodgement occurs in total hip replacement if polished stem or inadequate cementing of the collar is carried out. CONCLUSION: Gentle manipulative reduction under general anaesthesia of dislocated total hip replacement should be carried out if the polished femoral stem is used. Elsevier 2016-03-18 /pmc/articles/PMC4832038/ /pubmed/27060643 http://dx.doi.org/10.1016/j.ijscr.2016.03.019 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Rajeev, Aysha Mohamed, Abdalla Shaikh, Mazharuddin Banaszkiewicz, Paul Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement |
title | Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement |
title_full | Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement |
title_fullStr | Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement |
title_full_unstemmed | Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement |
title_short | Dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement |
title_sort | dislodgement of a cemented exeter femoral stem during closed manipulative reduction of a dislocated total hip replacement |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4832038/ https://www.ncbi.nlm.nih.gov/pubmed/27060643 http://dx.doi.org/10.1016/j.ijscr.2016.03.019 |
work_keys_str_mv | AT rajeevaysha dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement AT mohamedabdalla dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement AT shaikhmazharuddin dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement AT banaszkiewiczpaul dislodgementofacementedexeterfemoralstemduringclosedmanipulativereductionofadislocatedtotalhipreplacement |