Cargando…

Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device

Biological populations of cells show considerable cell-to-cell variability. Study of single cells and analysis of cell heterogeneity are considered to be critical in understanding biological processes such as stem cell differentiation and cancer development. Recent advances in lab-on-a-chip techniqu...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Ying, Basu, Srinjan, Laue, Ernest, Seshia, Ashwin A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Advanced Technology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4833703/
https://www.ncbi.nlm.nih.gov/pubmed/26963790
http://dx.doi.org/10.1016/j.bios.2016.02.069
_version_ 1782427372504481792
author Zhou, Ying
Basu, Srinjan
Laue, Ernest
Seshia, Ashwin A.
author_facet Zhou, Ying
Basu, Srinjan
Laue, Ernest
Seshia, Ashwin A.
author_sort Zhou, Ying
collection PubMed
description Biological populations of cells show considerable cell-to-cell variability. Study of single cells and analysis of cell heterogeneity are considered to be critical in understanding biological processes such as stem cell differentiation and cancer development. Recent advances in lab-on-a-chip techniques have allowed single-cell capture in microfluidic channels with the possibility of precise environmental control and high throughput of experiments with minimal usage of samples and reagents. In recent years, label-free techniques such as electrical impedance spectroscopy have emerged as a non-invasive approach to studying cell properties. In this study, we have designed and fabricated a microfluidic device that combines hydrodynamic trapping of single cells in pre-defined locations with the capability of running electrical impedance measurements within the same device. We have measured mouse embryonic stem cells (mESCs) at different states during differentiation (t=0 h, 24 h and 48 h) and quantitatively analysed the changes in electrical parameters of cells during differentiation. A marked increase in the magnitude of the cell impedance is found during cell differentiation, which can be attributed to an increase in cell size. The analysis of the measurements shows that the nucleus-to-cytoplasm ratio decreases during this process. The degree of cell heterogeneity is observed to be the highest when the cells are at the transition state (24 h), compare with cells at undifferentiated (0 h) and fully differentiated (48 h) states. The device enables highly efficient single cell trapping and provides sensitive, label-free electrical impedance measurements of individual cells, enabling the possibility of quantitatively analysing their physical state as well as studying the associated heterogeneity of a cell population.
format Online
Article
Text
id pubmed-4833703
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier Advanced Technology
record_format MEDLINE/PubMed
spelling pubmed-48337032016-07-15 Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device Zhou, Ying Basu, Srinjan Laue, Ernest Seshia, Ashwin A. Biosens Bioelectron Article Biological populations of cells show considerable cell-to-cell variability. Study of single cells and analysis of cell heterogeneity are considered to be critical in understanding biological processes such as stem cell differentiation and cancer development. Recent advances in lab-on-a-chip techniques have allowed single-cell capture in microfluidic channels with the possibility of precise environmental control and high throughput of experiments with minimal usage of samples and reagents. In recent years, label-free techniques such as electrical impedance spectroscopy have emerged as a non-invasive approach to studying cell properties. In this study, we have designed and fabricated a microfluidic device that combines hydrodynamic trapping of single cells in pre-defined locations with the capability of running electrical impedance measurements within the same device. We have measured mouse embryonic stem cells (mESCs) at different states during differentiation (t=0 h, 24 h and 48 h) and quantitatively analysed the changes in electrical parameters of cells during differentiation. A marked increase in the magnitude of the cell impedance is found during cell differentiation, which can be attributed to an increase in cell size. The analysis of the measurements shows that the nucleus-to-cytoplasm ratio decreases during this process. The degree of cell heterogeneity is observed to be the highest when the cells are at the transition state (24 h), compare with cells at undifferentiated (0 h) and fully differentiated (48 h) states. The device enables highly efficient single cell trapping and provides sensitive, label-free electrical impedance measurements of individual cells, enabling the possibility of quantitatively analysing their physical state as well as studying the associated heterogeneity of a cell population. Elsevier Advanced Technology 2016-07-15 /pmc/articles/PMC4833703/ /pubmed/26963790 http://dx.doi.org/10.1016/j.bios.2016.02.069 Text en © 2016 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhou, Ying
Basu, Srinjan
Laue, Ernest
Seshia, Ashwin A.
Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device
title Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device
title_full Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device
title_fullStr Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device
title_full_unstemmed Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device
title_short Single cell studies of mouse embryonic stem cell (mESC) differentiation by electrical impedance measurements in a microfluidic device
title_sort single cell studies of mouse embryonic stem cell (mesc) differentiation by electrical impedance measurements in a microfluidic device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4833703/
https://www.ncbi.nlm.nih.gov/pubmed/26963790
http://dx.doi.org/10.1016/j.bios.2016.02.069
work_keys_str_mv AT zhouying singlecellstudiesofmouseembryonicstemcellmescdifferentiationbyelectricalimpedancemeasurementsinamicrofluidicdevice
AT basusrinjan singlecellstudiesofmouseembryonicstemcellmescdifferentiationbyelectricalimpedancemeasurementsinamicrofluidicdevice
AT laueernest singlecellstudiesofmouseembryonicstemcellmescdifferentiationbyelectricalimpedancemeasurementsinamicrofluidicdevice
AT seshiaashwina singlecellstudiesofmouseembryonicstemcellmescdifferentiationbyelectricalimpedancemeasurementsinamicrofluidicdevice